  • 1. Device thrombogenicity emulation: a novel method for optimizing mechanical circulatory support device thromboresistance.
    Girdhar G; Xenos M; Alemu Y; Chiu WC; Lynch BE; Jesty J; Einav S; Slepian MJ; Bluestein D
    PLoS One; 2012; 7(3):e32463. PubMed ID: 22396768
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Device thrombogenicity emulation: a novel methodology for optimizing the thromboresistance of cardiovascular devices.
    Bluestein D; Girdhar G; Einav S; Slepian MJ
    J Biomech; 2013 Jan; 46(2):338-44. PubMed ID: 23219278
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Thromboresistance comparison of the HeartMate II ventricular assist device with the device thrombogenicity emulation- optimized HeartAssist 5 VAD.
    Chiu WC; Girdhar G; Xenos M; Alemu Y; Soares JS; Einav S; Slepian M; Bluestein D
    J Biomech Eng; 2014 Feb; 136(2):021014. PubMed ID: 24337144
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Device Thrombogenicity Emulation: An In Silico Predictor of In Vitro and In Vivo Ventricular Assist Device Thrombogenicity.
    Chiu WC; Tran PL; Khalpey Z; Lee E; Woo YR; Slepian MJ; Bluestein D
    Sci Rep; 2019 Feb; 9(1):2946. PubMed ID: 30814674
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Device Thrombogenicity Emulator (DTE)--design optimization methodology for cardiovascular devices: a study in two bileaflet MHV designs.
    Xenos M; Girdhar G; Alemu Y; Jesty J; Slepian M; Einav S; Bluestein D
    J Biomech; 2010 Aug; 43(12):2400-9. PubMed ID: 20483411
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Circulatory loop design and components introduce artifacts impacting in vitro evaluation of ventricular assist device thrombogenicity: A call for caution.
    Li M; Walk R; Roka-Moiia Y; Sheriff J; Bluestein D; Barth EJ; Slepian MJ
    Artif Organs; 2020 Jun; 44(6):E226-E237. PubMed ID: 31876310
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Design optimization of a mechanical heart valve for reducing valve thrombogenicity-A case study with ATS valve.
    Alemu Y; Girdhar G; Xenos M; Sheriff J; Jesty J; Einav S; Bluestein D
    ASAIO J; 2010; 56(5):389-96. PubMed ID: 20613492
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Platelet adhesion emulation: A novel method for estimating the device thrombosis potential of a ventricular assist device.
    Liu GM; Chen HB; Hou JF; Zhang Y; Hu SS
    Int J Artif Organs; 2020 Apr; 43(4):252-257. PubMed ID: 31709882
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ventricular Assist Device Implantation Configurations Impact Overall Mechanical Circulatory Support System Thrombogenic Potential.
    Chiu WC; Alemu Y; McLarty AJ; Einav S; Slepian MJ; Bluestein D
    ASAIO J; 2017; 63(3):285-292. PubMed ID: 27922885
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Platelet activation due to hemodynamic shear stresses: damage accumulation model and comparison to in vitro measurements.
    Nobili M; Sheriff J; Morbiducci U; Redaelli A; Bluestein D
    ASAIO J; 2008; 54(1):64-72. PubMed ID: 18204318
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Microfluidic emulation of mechanical circulatory support device shear-mediated platelet activation.
    Dimasi A; Rasponi M; Sheriff J; Chiu WC; Bluestein D; Tran PL; Slepian MJ; Redaelli A
    Biomed Microdevices; 2015 Dec; 17(6):117. PubMed ID: 26578003
    [TBL] [Abstract][Full Text] [Related]  

  • 12. On-Chip Platelet Activation Assessment: Microfluidic Emulation of Shear Stress Profiles Induced by Mechanical Circulatory Support Devices.
    Mencarini T; Bozzi S; Redaelli A
    Methods Mol Biol; 2022; 2373():201-212. PubMed ID: 34520014
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Rotary Blood Pumps as Long-Term Mechanical Circulatory Support: A Review of a 15-Year Berlin Experience.
    Hetzer R; Kaufmann MEng F; Potapov E; Krabatsch T; Delmo Walter EM
    Semin Thorac Cardiovasc Surg; 2016; 28(1):12-23. PubMed ID: 27568128
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In vitro evaluation of a novel hemodynamically optimized trileaflet polymeric prosthetic heart valve.
    Claiborne TE; Sheriff J; Kuetting M; Steinseifer U; Slepian MJ; Bluestein D
    J Biomech Eng; 2013 Feb; 135(2):021021. PubMed ID: 23445066
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Numerical model of total artificial heart hemodynamics and the effect of its size on stress accumulation.
    Marom G; Chiu WC; Slepian MJ; Bluestein D
    Annu Int Conf IEEE Eng Med Biol Soc; 2014; 2014():5651-4. PubMed ID: 25571277
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Device-induced platelet dysfunction in mechanically assisted circulation increases the risks of thrombosis and bleeding.
    Chen Z; Zhang J; Kareem K; Tran D; Conway RG; Arias K; Griffith BP; Wu ZJ
    Artif Organs; 2019 Aug; 43(8):745-755. PubMed ID: 30805954
    [TBL] [Abstract][Full Text] [Related]  

  • 17. On the Use of the Platelet Activity State Assay for the In Vitro Quantification of Platelet Activation in Blood Recirculating Devices for Extracorporeal Circulation.
    Consolo F; Valerio L; Brizzola S; Rota P; Marazzato G; Vincoli V; Reggiani S; Redaelli A; Fiore G
    Artif Organs; 2016 Oct; 40(10):971-980. PubMed ID: 26748664
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Aspirin has limited ability to modulate shear-mediated platelet activation associated with elevated shear stress of ventricular assist devices.
    Valerio L; Tran PL; Sheriff J; Brengle W; Ghosh R; Chiu WC; Redaelli A; Fiore GB; Pappalardo F; Bluestein D; Slepian MJ
    Thromb Res; 2016 Apr; 140():110-117. PubMed ID: 26938158
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Clinical experience with the MicroMed DeBakey ventricular assist device.
    Noon GP; Morley DL; Irwin S; Abdelsayed SV; Benkowski RJ; Lynch BE
    Ann Thorac Surg; 2001 Mar; 71(3 Suppl):S133-8; discussion S144-6. PubMed ID: 11265848
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Blood damage in Left Ventricular Assist Devices: Pump thrombosis or system thrombosis?
    Selmi M; Chiu WC; Chivukula VK; Melisurgo G; Beckman JA; Mahr C; Aliseda A; Votta E; Redaelli A; Slepian MJ; Bluestein D; Pappalardo F; Consolo F
    Int J Artif Organs; 2019 Mar; 42(3):113-124. PubMed ID: 30354870
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.