These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

172 related articles for article (PubMed ID: 22399929)

  • 1. A reusable PZT transducer for monitoring initial hydration and structural health of concrete.
    Yang Y; Divsholi BS; Soh CK
    Sensors (Basel); 2010; 10(5):5193-208. PubMed ID: 22399929
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Sub-frequency interval approach in electromechanical impedance technique for concrete structure health monitoring.
    Yang Y; Divsholi BS
    Sensors (Basel); 2010; 10(12):11644-61. PubMed ID: 22163548
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Sensitivity of PZT Impedance Sensors for Damage Detection of Concrete Structures.
    Yang Y; Hu Y; Lu Y
    Sensors (Basel); 2008 Jan; 8(1):327-346. PubMed ID: 27879711
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Efficacy of PZT Sensors Network Different Configurations in Damage Detection of Fiber-Reinforced Concrete Prisms under Repeated Loading.
    Naoum MC; Papadopoulos NA; Sapidis GM; Voutetaki ME
    Sensors (Basel); 2024 Aug; 24(17):. PubMed ID: 39275573
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Influence of Axial Load on Electromechanical Impedance (EMI) of Embedded Piezoceramic Transducers in Steel Fiber Concrete.
    Wang Z; Chen D; Zheng L; Huo L; Song G
    Sensors (Basel); 2018 Jun; 18(6):. PubMed ID: 29865190
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A Deep Learning Approach for Autonomous Compression Damage Identification in Fiber-Reinforced Concrete Using Piezoelectric Lead Zirconate Titanate Transducers.
    Sapidis GM; Kansizoglou I; Naoum MC; Papadopoulos NA; Chalioris CE
    Sensors (Basel); 2024 Jan; 24(2):. PubMed ID: 38257479
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Flexural Damage Diagnosis in Reinforced Concrete Beams Using a Wireless Admittance Monitoring System-Tests and Finite Element Analysis.
    Chalioris CE; Kytinou VK; Voutetaki ME; Karayannis CG
    Sensors (Basel); 2021 Jan; 21(3):. PubMed ID: 33498337
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Structural Damage Detection through EMI and Wave Propagation Techniques Using Embedded PZT Smart Sensing Units.
    Gayakwad H; Thiyagarajan JS
    Sensors (Basel); 2022 Mar; 22(6):. PubMed ID: 35336470
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of External Vibration on PZT Impedance Signature.
    Yang Y; Miao A
    Sensors (Basel); 2008 Nov; 8(11):6846-6859. PubMed ID: 27873903
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Fuzzy Logic-Based and Nondestructive Concrete Strength Evaluation Using Modified Carbon Nanotubes as a Hybrid PZT-CNT Sensor.
    Tareen N; Kim J; Kim WK; Park S
    Materials (Basel); 2021 May; 14(11):. PubMed ID: 34070776
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Sensing of Damage and Repair of Cement Mortar Using Electromechanical Impedance.
    Taha H; Ball RJ; Paine K
    Materials (Basel); 2019 Nov; 12(23):. PubMed ID: 31783565
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Health monitoring of bacterial concrete structure under dynamic loading using electro-mechanical impedance technique: a numerical approach.
    Maurya KK; Rawat A; Shanker R
    Environ Sci Pollut Res Int; 2023 Feb; 30(10):25382-25401. PubMed ID: 35836050
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A study of concrete slab damage detection based on the electromechanical impedance method.
    Hu X; Zhu H; Wang D
    Sensors (Basel); 2014 Oct; 14(10):19897-909. PubMed ID: 25341438
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Damage Evaluation of Concrete Column under Impact Load Using a Piezoelectric-Based EMI Technique.
    Fan S; Zhao S; Qi B; Kong Q
    Sensors (Basel); 2018 May; 18(5):. PubMed ID: 29772769
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Optimum PZT Patch Size for Corrosion Detection in Reinforced Concrete Using the Electromechanical Impedance Technique.
    Hire JH; Hosseini S; Moradi F
    Sensors (Basel); 2021 Jun; 21(11):. PubMed ID: 34198764
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Transducer loading effect on the performance of PZT-based SHM systems.
    Baptista FG; Filho JV
    IEEE Trans Ultrason Ferroelectr Freq Control; 2010 Apr; 57(4):933-41. PubMed ID: 20378455
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Monitoring of Epoxy-Grouted Bonding Strength Development between an Anchored Steel Bar and Concrete, Using PZT-Enabled Active Sensing.
    Jiang J; Hei C; Feng Q; Jiang J
    Sensors (Basel); 2019 May; 19(9):. PubMed ID: 31064124
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A proof of concept study on reliability assessment of different metal foil length based piezoelectric sensor for electromechanical impedance techniques.
    Parida L; Moharana S; Vicente R; Ascensão G
    Sci Rep; 2024 Jan; 14(1):699. PubMed ID: 38184698
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Debonding Damage Detection in CFRP Plate-Strengthened Steel Beam Using Electromechanical Impedance Technique.
    Wang B; Sun Y; Li Y; Zhang C
    Sensors (Basel); 2019 May; 19(10):. PubMed ID: 31109030
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Concrete Infill Monitoring in Concrete-Filled FRP Tubes Using a PZT-Based Ultrasonic Time-of-Flight Method.
    Luo M; Li W; Hei C; Song G
    Sensors (Basel); 2016 Dec; 16(12):. PubMed ID: 27941617
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.