These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
133 related articles for article (PubMed ID: 22402389)
1. VMAT testing for an Elekta accelerator. Kaurin DG; Sweeney LE; Marshall EI; Mahendra S J Appl Clin Med Phys; 2012 Mar; 13(2):3725. PubMed ID: 22402389 [TBL] [Abstract][Full Text] [Related]
2. Do technological advances in linear accelerators improve dosimetric outcomes in stereotaxy? A head-on comparison of seven linear accelerators using volumetric modulated arc therapy-based stereotactic planning. Sarkar B; Pradhan A; Munshi A Indian J Cancer; 2016; 53(1):166-73. PubMed ID: 27146771 [TBL] [Abstract][Full Text] [Related]
3. Validation of a new control system for Elekta accelerators facilitating continuously variable dose rate. Bertelsen A; Lorenzen EL; Brink C Med Phys; 2011 Aug; 38(8):4802-10. PubMed ID: 21928653 [TBL] [Abstract][Full Text] [Related]
4. Evaluation of the Elekta Agility MLC performance using high-resolution log files. Kabat CN; Defoor DL; Myers P; Kirby N; Rasmussen K; Saenz DL; Mavroidis P; Papanikolaou N; Stathakis S Med Phys; 2019 Mar; 46(3):1397-1407. PubMed ID: 30702748 [TBL] [Abstract][Full Text] [Related]
5. Comparison of MLC positioning deviations using log files and establishment of specific assessment parameters for different accelerators with IMRT and VMAT. Lin X; Sun T; Liu X; Zhang G; Yin Y Radiat Oncol; 2022 Jul; 17(1):123. PubMed ID: 35842671 [TBL] [Abstract][Full Text] [Related]
6. Commissioning and quality assurance for VMAT delivery systems: An efficient time-resolved system using real-time EPID imaging. Zwan BJ; Barnes MP; Hindmarsh J; Lim SB; Lovelock DM; Fuangrod T; O'Connor DJ; Keall PJ; Greer PB Med Phys; 2017 Aug; 44(8):3909-3922. PubMed ID: 28564208 [TBL] [Abstract][Full Text] [Related]
7. A generalized inverse planning tool for volumetric-modulated arc therapy. Cao D; Afghan MK; Ye J; Chen F; Shepard DM Phys Med Biol; 2009 Nov; 54(21):6725-38. PubMed ID: 19841516 [TBL] [Abstract][Full Text] [Related]
8. Interplay effect on a 6-MV flattening-filter-free linear accelerator with high dose rate and fast multi-leaf collimator motion treating breast and lung phantoms. Netherton T; Li Y; Nitsch P; Shaitelman S; Balter P; Gao S; Klopp A; Muruganandham M; Court L Med Phys; 2018 Jun; 45(6):2369-2376. PubMed ID: 29611210 [TBL] [Abstract][Full Text] [Related]
9. The comparison of VMAT test results for Clinac 2300C/D and TrueBeam accelerators. Latala A; Fujak E; Walewska A; Kukołowicz P Med Dosim; 2020 Autumn; 45(3):219-224. PubMed ID: 32008886 [TBL] [Abstract][Full Text] [Related]
10. A multi-institution evaluation of MLC log files and performance in IMRT delivery. Kerns JR; Childress N; Kry SF Radiat Oncol; 2014 Aug; 9():176. PubMed ID: 25112533 [TBL] [Abstract][Full Text] [Related]
11. Analysis of direct clinical consequences of MLC positional errors in volumetric-modulated arc therapy using 3D dosimetry system. Nithiyanantham K; Mani GK; Subramani V; Mueller L; Palaniappan KK; Kataria T J Appl Clin Med Phys; 2015 Sep; 16(5):296–305. PubMed ID: 26699311 [TBL] [Abstract][Full Text] [Related]
12. Evaluation of the Impact of the Linac MLC and Gantry Sag in volumetric modulated arc therapy. Milan T; Grogan G; Ebert MA; Rowshanfarzad P Med Phys; 2019 May; 46(5):1984-1994. PubMed ID: 30870581 [TBL] [Abstract][Full Text] [Related]
13. Does the option to rotate the Elekta Beam Modulator MLC during VMAT IMRT delivery confer advantage?--a study of 'parked gaps'. Webb S Phys Med Biol; 2010 Jun; 55(11):N303-19. PubMed ID: 20442462 [TBL] [Abstract][Full Text] [Related]
14. Quality assurance of VMAT on flattened and flattening filter-free accelerators using a high spatial resolution detector. Matar FS; Wilkinson D; Davis J; Biasi G; Causer T; Fuduli I; Brace O; Stansook N; Carolan M; Rosenfeld AB; Petasecca M J Appl Clin Med Phys; 2020 Jun; 21(6):44-52. PubMed ID: 32277745 [TBL] [Abstract][Full Text] [Related]
15. A novel method for routine quality assurance of volumetric-modulated arc therapy. Wang Q; Dai J; Zhang K Med Phys; 2013 Oct; 40(10):101712. PubMed ID: 24089902 [TBL] [Abstract][Full Text] [Related]
16. A method to reconstruct and apply 3D primary fluence for treatment delivery verification. Liu S; Mazur TR; Li H; Curcuru A; Green OL; Sun B; Mutic S; Yang D J Appl Clin Med Phys; 2017 Jan; 18(1):128-138. PubMed ID: 28291913 [TBL] [Abstract][Full Text] [Related]
17. Commissioning of volumetric modulated arc therapy (VMAT). Bedford JL; Warrington AP Int J Radiat Oncol Biol Phys; 2009 Feb; 73(2):537-45. PubMed ID: 19147018 [TBL] [Abstract][Full Text] [Related]
18. RapidArc patient specific mechanical delivery accuracy under extreme mechanical limits using linac log files. Wijesooriya K; Aliotta E; Benedict S; Read P; Rich T; Larner J Med Phys; 2012 Apr; 39(4):1846-53. PubMed ID: 22482606 [TBL] [Abstract][Full Text] [Related]
19. Feasibility of a remote, automated daily delivery verification of volumetric-modulated arc therapy treatments using a commercial record and verify system. Fontenot JD J Appl Clin Med Phys; 2012 Mar; 13(2):3606. PubMed ID: 22402378 [TBL] [Abstract][Full Text] [Related]
20. Volumetric modulated arc therapy: IMRT in a single gantry arc. Otto K Med Phys; 2008 Jan; 35(1):310-7. PubMed ID: 18293586 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]