These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Methylene blue and pulse oximeter readings in a patient undergoing transurethral procedure. Schleifer WF; Chapin JW; Cuka DJ; Taylor RJ Urology; 1990 Dec; 36(6):537-8. PubMed ID: 2247925 [No Abstract] [Full Text] [Related]
3. Methylene blue and pulse oximetry readings: spuriouser and spuriouser. Eisenkraft JB Anesthesiology; 1988 Jan; 68(1):171-2. PubMed ID: 3337381 [No Abstract] [Full Text] [Related]
4. Pulse oximetry in methaemoglobinaemia. Failure to detect low oxygen saturation. Rieder HU; Frei FJ; Zbinden AM; Thomson DA Anaesthesia; 1989 Apr; 44(4):326-7. PubMed ID: 2719205 [TBL] [Abstract][Full Text] [Related]
5. Effect of methylene blue on the absorbance of solutions of haemoglobin. Gorman ES; Shnider MR Br J Anaesth; 1988 Mar; 60(4):439-44. PubMed ID: 3355740 [TBL] [Abstract][Full Text] [Related]
6. Characterization of the Rapid Drop in Pulse Oximetry Reading After Intraoperative Administration of Methylene Blue in Open Thoracoabdominal Aortic Repairs. Rong LQ; Mauer E; Mustapich TL; White RS; Di Franco A; Girardi LN; Gaudino M; Pryor KO Anesth Analg; 2019 Nov; 129(5):e142-e145. PubMed ID: 31397700 [TBL] [Abstract][Full Text] [Related]
7. False indication of arterial oxygen desaturation and methemoglobinemia following injection of methylene blue in urological surgery. Kirlangitis JJ; Middaugh RE; Zablocki A; Rodriquez F Mil Med; 1990 Jun; 155(6):260-2. PubMed ID: 2122301 [TBL] [Abstract][Full Text] [Related]
8. Effect on oximetry of dyes used for sentinel lymph node biopsy. Piñero A; Illana J; García-Palenciano C; Cañizarese F; Canteras M; Cañadillas V; Durán E; Parilla P Arch Surg; 2004 Nov; 139(11):1204-7. PubMed ID: 15546820 [TBL] [Abstract][Full Text] [Related]
9. [False decrease in pulse oximetry readings due to patent blue in a patient with breast cancer]. Murakami T; Kayo R; Kajita I; Cho S; Saito H Masui; 2003 Aug; 52(8):909-11. PubMed ID: 13677292 [TBL] [Abstract][Full Text] [Related]
10. Methylene blue and parathyroid adenoma localization: Three new cases of a rare cutaneous complication. Lieberman ED; Thambi R; Pytynia KB Ear Nose Throat J; 2016 Feb; 95(2):70-2. PubMed ID: 26930332 [TBL] [Abstract][Full Text] [Related]
11. Cerebral oximetry changes "out of the blue". Yu JS; Seefelder C Paediatr Anaesth; 2020 May; 30(5):626-627. PubMed ID: 32243671 [No Abstract] [Full Text] [Related]
15. False desaturation due to intradermal patent blue dye. Morell RC; Heyneker T; Kashtan HI; Ruppe C Anesthesiology; 1993 Feb; 78(2):363-4. PubMed ID: 8439032 [No Abstract] [Full Text] [Related]
16. Pulse oximetry signals local anesthetic-induced methemoglobinemia. Johnson PL Anesth Prog; 1994; 41(1):11-2. PubMed ID: 8629741 [TBL] [Abstract][Full Text] [Related]
17. Falsely normal saturation reading with the pulse oximeter. Costarino AT; Davis DA; Keon TP Anesthesiology; 1987 Nov; 67(5):830-1. PubMed ID: 3674493 [No Abstract] [Full Text] [Related]
18. Patent blue sentinel node mapping in cervical cancer patients may lead to decreased pulse oximeter readings and positive methaemoglobin results. Kieckbusch H; Coldewey SM; Hollenhorst J; Haeseler G; Hillemanns P; Hertel H Eur J Anaesthesiol; 2008 May; 25(5):365-8. PubMed ID: 18272013 [TBL] [Abstract][Full Text] [Related]
19. Characterization of the Rapid Drop in Pulse Oximetry Reading After Intraoperative Administration of Methylene Blue in Open Thoracoabdominal Aortic Repairs. Woehlck HJ; Zundel MT Anesth Analg; 2020 Jun; 130(6):e179. PubMed ID: 32243293 [No Abstract] [Full Text] [Related]