These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

168 related articles for article (PubMed ID: 22406221)

  • 1. 57Co half-life determination.
    da Silva CJ; Iwahara A; Moreira DS; Delgado JU; Gomes RS
    Appl Radiat Isot; 2012 Sep; 70(9):1924-6. PubMed ID: 22406221
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Standardization of (166m)Ho and 243Am/239Np by live-timed anti-coincidence counting with extending dead time.
    da Silva CJ; Loureiro JS; Delgado JU; Poledna R; Moreira DS; Iwahara A; Tauhata L; da Silva RL; Lopes RT
    Appl Radiat Isot; 2012 Sep; 70(9):2056-9. PubMed ID: 22417696
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Radioactivity measurement of 18F in 16 ml vials for calibration of radionuclide calibrators.
    Wurdiyanto G; Marsoem P; Candra H; Wijono P
    Appl Radiat Isot; 2012 Sep; 70(9):2237-9. PubMed ID: 22445106
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Standardization of 65Zn by sum-peak method.
    Oliveira EM; Iwahara A; Poledna R; Delgado JU; da Silva CJ; da Silva RL; Lopes RT
    Appl Radiat Isot; 2012 Sep; 70(9):2087-90. PubMed ID: 22425414
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Standardization of 18F by digital coincidence counting.
    Kim EJ; Park TS; Lee JM; Shik Hahm D; Lee KB
    Appl Radiat Isot; 2012 Sep; 70(9):2103-6. PubMed ID: 22484142
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Radioactivity measurements of 177Lu, 111In and 123I by different absolute methods.
    Rezende EA; Correia AR; Iwahara A; da Silva CJ; Tauhata L; Poledna R; da Silva RL; de Oliveira EM; de Oliveira AE
    Appl Radiat Isot; 2012 Sep; 70(9):2081-6. PubMed ID: 22401938
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Development of the primary measurement standard for gaseous radon-222 activity.
    Kim BC; Lee KB; Park TS; Lee JM; Lee SH; Oh PJ; Lee MK; Ahn JK
    Appl Radiat Isot; 2012 Sep; 70(9):1934-9. PubMed ID: 22607994
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Standardization and decay data determinations of 125I, 54Mn and 203Hg.
    da Silva MA; Poledna R; Iwahara A; da Silva CJ; Delgado JU; Lopes RT
    Appl Radiat Isot; 2006; 64(10-11):1440-5. PubMed ID: 16621584
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Standardization, decay data measurements and evaluation of 64Cu.
    Bé MM; Cassette P; Lépy MC; Amiot MN; Kossert K; Nähle OJ; Ott O; Wanke C; Dryak P; Ratel G; Sahagia M; Luca A; Antohe A; Johansson L; Keightley J; Pearce A
    Appl Radiat Isot; 2012 Sep; 70(9):1894-9. PubMed ID: 22406222
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Standardization of (99m)Tc by means of a software coincidence system.
    Brito AB; Koskinas MF; Litvak F; Toledo F; Dias MS
    Appl Radiat Isot; 2012 Sep; 70(9):2097-102. PubMed ID: 22425415
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The direct measurement of 57Co activity by the sum-peak method.
    Novković D; Kandić A; Vukanac I; Đurašević M; Milošević Z
    Appl Radiat Isot; 2012 Sep; 70(9):2154-6. PubMed ID: 22436450
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Activity measurement of electron-capture radionuclides by a KX-gamma-coincidence method at VNIIM.
    Tereshchenko E; Moiseev N
    Appl Radiat Isot; 2012 Sep; 70(9):2066-9. PubMed ID: 22560775
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Standardization of 64Cu and 68Ga by the 4π(PC)β-γ coincidence method and calibration of the ionization chamber.
    Sahagia M; Luca A; Antohe A; Ivan C
    Appl Radiat Isot; 2012 Sep; 70(9):2025-30. PubMed ID: 22417699
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Determination of plutonium isotopes in seawater reference materials using isotope-dilution ICP-MS.
    Zheng J; Yamada M
    Appl Radiat Isot; 2012 Sep; 70(9):1944-8. PubMed ID: 22386661
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison between two absolute methods used for 177Lu activity measurements and its standardization.
    Capogni M; Cozzella ML; De Felice P; Fazio A
    Appl Radiat Isot; 2012 Sep; 70(9):2075-80. PubMed ID: 22464789
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Standardization of a 85Sr solution by three methods.
    Broda R; Dziel T; Muklanowicz A
    Appl Radiat Isot; 2012 Sep; 70(9):2222-6. PubMed ID: 22425416
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Half-life determination of 88Kr and 138Xe.
    Wang SL; Bai T; Li Q; Chen ZY; Shi QL; Li XS; Zhang XL; Xie F; Chang YF
    Appl Radiat Isot; 2012 Sep; 70(9):1927-30. PubMed ID: 22424743
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Measurements of some radionuclides using a new TDCR system and an ultra low-level conventional LSC counter in CPST, Lithuania.
    Gudelis A; Vinčiūnas A; Butkus P; Pranaitis M
    Appl Radiat Isot; 2012 Sep; 70(9):2204-8. PubMed ID: 22578994
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Standardization of 125I and 109Cd by the photon-photon coincidence method in PTKMR-BATAN.
    Marsoem P; Wurdiyanto G; Candra H
    Appl Radiat Isot; 2012 Sep; 70(9):2060-2. PubMed ID: 22484138
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Absolute standardization of 241Pu by the TDCR technique and effect of the beta spectral shape.
    van Wyngaardt WM; Simpson BR; van Staden MJ; Lubbe J
    Appl Radiat Isot; 2012 Sep; 70(9):2188-94. PubMed ID: 22424838
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.