BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

520 related articles for article (PubMed ID: 22423604)

  • 1. EVEREST II randomized clinical trial: predictors of mitral valve replacement in de novo surgery or after the MitraClip procedure.
    Glower D; Ailawadi G; Argenziano M; Mack M; Trento A; Wang A; Lim DS; Gray W; Grayburn P; Dent J; Gillam L; Sethuraman B; Feldman T; Foster E; Mauri L; Kron I;
    J Thorac Cardiovasc Surg; 2012 Apr; 143(4 Suppl):S60-3. PubMed ID: 22423604
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Surgical revision after percutaneous mitral repair with the MitraClip device.
    Argenziano M; Skipper E; Heimansohn D; Letsou GV; Woo YJ; Kron I; Alexander J; Cleveland J; Kong B; Davidson M; Vassiliades T; Krieger K; Sako E; Tibi P; Galloway A; Foster E; Feldman T; Glower D;
    Ann Thorac Surg; 2010 Jan; 89(1):72-80; discussion p 80. PubMed ID: 20103209
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical outcomes of conventional surgery versus MitraClip® therapy for moderate to severe symptomatic mitral valve regurgitation in the elderly population: an institutional experience.
    Alozie A; Paranskaya L; Westphal B; Kaminski A; Sherif M; Sindt M; Kische S; Schubert J; Diedrich D; Ince H; Steinhoff G; Öner A
    BMC Cardiovasc Disord; 2017 Mar; 17(1):85. PubMed ID: 28320316
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Late surgical mitral valve repair after percutaneous repair with the MitraClip system.
    Rogers JH; Yeo KK; Carroll JD; Cleveland J; Reece TB; Gillinov AM; Rodriguez L; Whitlow P; Woo YJ; Herrmann HC; Young JN
    J Card Surg; 2009; 24(6):677-81. PubMed ID: 19682161
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Extended use of percutaneous edge-to-edge mitral valve repair beyond EVEREST (Endovascular Valve Edge-to-Edge Repair) criteria: 30-day and 12-month clinical and echocardiographic outcomes from the GRASP (Getting Reduction of Mitral Insufficiency by Percutaneous Clip Implantation) registry.
    Attizzani GF; Ohno Y; Capodanno D; Cannata S; Dipasqua F; Immé S; Mangiafico S; Barbanti M; Ministeri M; Cageggi A; Pistritto AM; Giaquinta S; Farruggio S; Chiarandà M; Ronsivalle G; Schnell A; Scandura S; Tamburino C; Capranzano P; Grasso C
    JACC Cardiovasc Interv; 2015 Jan; 8(1 Pt A):74-82. PubMed ID: 25499300
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Acute and 12-month results with catheter-based mitral valve leaflet repair: the EVEREST II (Endovascular Valve Edge-to-Edge Repair) High Risk Study.
    Whitlow PL; Feldman T; Pedersen WR; Lim DS; Kipperman R; Smalling R; Bajwa T; Herrmann HC; Lasala J; Maddux JT; Tuzcu M; Kapadia S; Trento A; Siegel RJ; Foster E; Glower D; Mauri L; Kar S;
    J Am Coll Cardiol; 2012 Jan; 59(2):130-9. PubMed ID: 22222076
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Percutaneous MitraClip Device or Surgical Mitral Valve Repair in Patients With Primary Mitral Regurgitation Who Are Candidates for Surgery: Design and Rationale of the REPAIR MR Trial.
    McCarthy PM; Whisenant B; Asgar AW; Ailawadi G; Hermiller J; Williams M; Morse A; Rinaldi M; Grayburn P; Thomas JD; Martin R; Asch FM; Shu Y; Sundareswaran K; Moat N; Kar S
    J Am Heart Assoc; 2023 Feb; 12(4):e027504. PubMed ID: 36752231
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Mitral Valve Surgery After Failed MitraClip: A Single-Center Experience.
    Rader F; Siegel RJ; Flint N; Minhas H; Shmueli YG; Shiota T; Trento A
    J Invasive Cardiol; 2021 Apr; 33(4):E236-E243. PubMed ID: 33794477
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Incremental value of three-dimensional transoesophageal echocardiography for guiding double percutaneous MitraClip ® implantation in a 'no option' patient.
    Ciobanu A; Bennett S; Azam M; Clark A; Vinereanu D
    Eur J Echocardiogr; 2011 Feb; 12(2):E11. PubMed ID: 20876188
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Residual mitral valve regurgitation after percutaneous mitral valve repair with the MitraClip® system is a risk factor for adverse one-year outcome.
    Paranskaya L; D'Ancona G; Bozdag-Turan I; Akin I; Kische S; Turan GR; Rehders T; Ortak J; Nienaber CA; Ince H
    Catheter Cardiovasc Interv; 2013 Mar; 81(4):609-17. PubMed ID: 22887450
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Surgical revision after percutaneous mitral valve repair by edge-to-edge device: when the strategy fails in the highest risk surgical population.
    Alozie A; Westphal B; Kische S; Kaminski A; Paranskaya L; Bozdag-Turan I; Ortak J; Schubert J; Steinhoff G; Ince H
    Eur J Cardiothorac Surg; 2014 Jul; 46(1):55-60. PubMed ID: 24321993
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Reduction of mitral valve regurgitation with Mitraclip® percutaneous system.
    Tamburino C; Immè S; Barbanti M; Mulè M; Pistritto AM; Aruta P; Cammalleri V; Scarabelli M; Mangiafico S; Scandura S; Ussia GP
    Minerva Cardioangiol; 2010 Oct; 58(5):589-98. PubMed ID: 20948505
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Pecutaneous mitral valve repair].
    Pedrazzini GB; Sürder D; Faletra F; Moccetti T
    Praxis (Bern 1994); 2013 Feb; 102(5):265-71. PubMed ID: 23446236
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Surgical revision of failed percutaneous edge-to-edge mitral valve repair: lessons learned.
    Takayuki G; Sören S; Kristin R; Harnath A; Grimmig O; Sören J; Dirk F
    Interact Cardiovasc Thorac Surg; 2019 Jun; 28(6):900-907. PubMed ID: 30698735
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Randomized Comparison of Percutaneous Repair and Surgery for Mitral Regurgitation: 5-Year Results of EVEREST II.
    Feldman T; Kar S; Elmariah S; Smart SC; Trento A; Siegel RJ; Apruzzese P; Fail P; Rinaldi MJ; Smalling RW; Hermiller JB; Heimansohn D; Gray WA; Grayburn PA; Mack MJ; Lim DS; Ailawadi G; Herrmann HC; Acker MA; Silvestry FE; Foster E; Wang A; Glower DD; Mauri L;
    J Am Coll Cardiol; 2015 Dec; 66(25):2844-2854. PubMed ID: 26718672
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Mitral annular motion in patients after transcatheter MitraClip and mitral valve surgery.
    Toyama K; Rader F; Ayabe K; Kar S; Trento A; Nishioka T; De Robertis MA; Siegel RJ
    Echocardiography; 2017 Mar; 34(3):334-339. PubMed ID: 28130803
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Three hundred robotic-assisted mitral valve repairs: the Cedars-Sinai experience.
    Ramzy D; Trento A; Cheng W; De Robertis MA; Mirocha J; Ruzza A; Kass RM
    J Thorac Cardiovasc Surg; 2014 Jan; 147(1):228-35. PubMed ID: 24199760
    [TBL] [Abstract][Full Text] [Related]  

  • 18. One year clinical efficacy and reverse cardiac remodelling in patients with severe mitral regurgitation and reduced ejection fraction after MitraClip implantation.
    Pleger ST; Schulz-Schönhagen M; Geis N; Mereles D; Chorianopoulos E; Antaredja M; Lewening M; Katus HA; Bekeredjian R
    Eur J Heart Fail; 2013 Aug; 15(8):919-27. PubMed ID: 23512096
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Acute changes of mitral valve geometry during interventional edge-to-edge repair with the MitraClip system are associated with midterm outcomes in patients with functional valve disease: preliminary results from a prospective single-center study.
    Schueler R; Momcilovic D; Weber M; Welz A; Werner N; Mueller C; Ghanem A; Nickenig G; Hammerstingl C
    Circ Cardiovasc Interv; 2014 Jun; 7(3):390-9. PubMed ID: 24895448
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Percutaneous mitral valve repair with the MitraClip system according to the predicted risk by the logistic EuroSCORE: preliminary results from the German Transcatheter Mitral Valve Interventions (TRAMI) Registry.
    Wiebe J; Franke J; Lubos E; Boekstegers P; Schillinger W; Ouarrak T; May AE; Eggebrecht H; Kuck KH; Baldus S; Senges J; Sievert H;
    Catheter Cardiovasc Interv; 2014 Oct; 84(4):591-8. PubMed ID: 24664460
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 26.