These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

92 related articles for article (PubMed ID: 22425382)

  • 1. Study of factors affecting the magnitude and nature of ultrasound exposure with in vitro set-ups.
    Leskinen JJ; Hynynen K
    Ultrasound Med Biol; 2012 May; 38(5):777-94. PubMed ID: 22425382
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Analysis of ultrasound fields in cell culture wells for in vitro ultrasound therapy experiments.
    Hensel K; Mienkina MP; Schmitz G
    Ultrasound Med Biol; 2011 Dec; 37(12):2105-15. PubMed ID: 22107908
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Stimulation of bone repair with ultrasound: a review of the possible mechanic effects.
    Padilla F; Puts R; Vico L; Raum K
    Ultrasonics; 2014 Jul; 54(5):1125-45. PubMed ID: 24507669
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Characterization of the ultrasound beam produced by the MIST therapy, wound healing system.
    Keltie K; Reay CA; Bousfield DR; Cole H; Ward B; Oates CP; Sims AJ
    Ultrasound Med Biol; 2013 Jul; 39(7):1233-40. PubMed ID: 23562019
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Treatment of near-skull brain tissue with a focused device using shear-mode conversion: a numerical study.
    Pichardo S; Hynynen K
    Phys Med Biol; 2007 Dec; 52(24):7313-32. PubMed ID: 18065841
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Acoustic power measurement of high intensity focused ultrasound in medicine based on radiation force.
    Shou W; Huang X; Duan S; Xia R; Shi Z; Geng X; Li F
    Ultrasonics; 2006 Dec; 44 Suppl 1():e17-20. PubMed ID: 16860359
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Thermal therapy for breast tumors by using a cylindrical ultrasound phased array with multifocus pattern scanning: a preliminary numerical study.
    Ho CS; Ju KC; Cheng TY; Chen YY; Lin WL
    Phys Med Biol; 2007 Aug; 52(15):4585-99. PubMed ID: 17634652
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of a shock wave induced cavitation activity both in vitro and in vivo.
    Tu J; Matula TJ; Bailey MR; Crum LA
    Phys Med Biol; 2007 Oct; 52(19):5933-44. PubMed ID: 17881810
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Modeling of interaction between therapeutic ultrasound propagation and cavitation bubbles.
    Liebler M; Dreyer T; Riedlinger RE
    Ultrasonics; 2006 Dec; 44 Suppl 1():e319-24. PubMed ID: 16908041
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of externally applied focused acoustic energy on clot disruption in vitro.
    Westermark S; Wiksell H; Elmqvist H; Hultenby K; Berglund H
    Clin Sci (Lond); 1999 Jul; 97(1):67-71. PubMed ID: 10369795
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Myocardial lesion formation using high-intensity focused ultrasound.
    Engel DJ; Muratore R; Hirata K; Otsuka R; Fujikura K; Sugioka K; Marboe C; Lizzi FL; Homma S
    J Am Soc Echocardiogr; 2006 Jul; 19(7):932-7. PubMed ID: 16825005
    [TBL] [Abstract][Full Text] [Related]  

  • 12. MR guided focused ultrasound: technical acceptance measures for a clinical system.
    Gorny KR; Hangiandreou NJ; Hesley GK; Gostout BS; McGee KP; Felmlee JP
    Phys Med Biol; 2006 Jun; 51(12):3155-73. PubMed ID: 16757869
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Intradiscal thermal therapy using interstitial ultrasound: an in vivo investigation in ovine cervical spine.
    Nau WH; Diederich CJ; Shu R; Kinsey A; Bass E; Lotz J; Hu S; Simko J; Ferrier W; Sutton J; Attawia M; Pellegrino R
    Spine (Phila Pa 1976); 2007 Mar; 32(5):503-11. PubMed ID: 17334283
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Beam localization in HIFU temperature measurements using thermocouples, with application to cooling by large blood vessels.
    Dasgupta S; Banerjee RK; Hariharan P; Myers MR
    Ultrasonics; 2011 Feb; 51(2):171-80. PubMed ID: 20817250
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The use of a segmented transducer for rib sparing in HIFU treatments.
    Civale J; Clarke R; Rivens I; ter Haar G
    Ultrasound Med Biol; 2006 Nov; 32(11):1753-61. PubMed ID: 17112961
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Design and experiment of 256-element ultrasound phased array for noninvasive focused ultrasound surgery.
    Lu M; Wan M; Xu F; Wang X; Chang X
    Ultrasonics; 2006 Dec; 44 Suppl 1():e325-30. PubMed ID: 16949119
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Simulation of sound field in a tissue medium generated by a concave spherically annular transducer.
    Qian S; Kamakura T; Akiyama M
    Ultrasonics; 2006 Dec; 44 Suppl 1():e271-4. PubMed ID: 16843509
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A buoyancy method for the measurement of total ultrasound power generated by HIFU transducers.
    Shaw A
    Ultrasound Med Biol; 2008 Aug; 34(8):1327-42. PubMed ID: 18471952
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Treatment of murine tumors using dual-frequency ultrasound in an experimental in vivo model.
    Barati AH; Mokhtari-Dizaji M; Mozdarani H; Bathaie SZ; Hassan ZM
    Ultrasound Med Biol; 2009 May; 35(5):756-63. PubMed ID: 19195770
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Magnetic resonance imaging-guided focused ultrasound for thermal ablation in the brain: a feasibility study in a swine model.
    Cohen ZR; Zaubermann J; Harnof S; Mardor Y; Nass D; Zadicario E; Hananel A; Castel D; Faibel M; Ram Z
    Neurosurgery; 2007 Apr; 60(4):593-600; discussion 600. PubMed ID: 17415195
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.