These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 22425442)

  • 21. Construction of universal rotations from point-to-point transformations.
    Luy B; Kobzar K; Skinner TE; Khaneja N; Glaser SJ
    J Magn Reson; 2005 Oct; 176(2):179-86. PubMed ID: 16009584
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The Fantastic Four: A plug 'n' play set of optimal control pulses for enhancing NMR spectroscopy.
    Nimbalkar M; Luy B; Skinner TE; Neves JL; Gershenzon NI; Kobzar K; Bermel W; Glaser SJ
    J Magn Reson; 2013 Mar; 228():16-31. PubMed ID: 23333616
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Robust hyperpolarized (13)C metabolic imaging with selective non-excitation of pyruvate (SNEP).
    Chen WC; Teo XQ; Lee MY; Radda GK; Lee P
    NMR Biomed; 2015 Aug; 28(8):1021-30. PubMed ID: 26119950
    [TBL] [Abstract][Full Text] [Related]  

  • 24. J pulses for multiplet-selective NMR.
    Bendall MR; Skinner TE
    J Magn Reson; 1999 Dec; 141(2):261-70. PubMed ID: 10579949
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Optimal control of coupled spin dynamics: design of NMR pulse sequences by gradient ascent algorithms.
    Khaneja N; Reiss T; Kehlet C; Schulte-Herbrüggen T; Glaser SJ
    J Magn Reson; 2005 Feb; 172(2):296-305. PubMed ID: 15649756
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Generalized equation for describing the magnetization in spoiled gradient-echo imaging.
    Murase K
    Magn Reson Imaging; 2011 Jun; 29(5):723-30. PubMed ID: 21524871
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Improving excitation and inversion accuracy by optimized RF pulse using genetic algorithm.
    Pang Y; Shen GX
    J Magn Reson; 2007 May; 186(1):86-93. PubMed ID: 17379555
    [TBL] [Abstract][Full Text] [Related]  

  • 28. The time-dependence of exchange-induced relaxation during modulated radio frequency pulses.
    Sorce DJ; Michaeli S; Garwood M
    J Magn Reson; 2006 Mar; 179(1):136-9. PubMed ID: 16298149
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Preserving the excitation profile of small flip angle RF pulses in the presence of rapid transverse relaxation.
    Shen J
    J Magn Reson; 2012 Nov; 224():8-12. PubMed ID: 23000975
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Spatial excitation using variable-density spiral trajectories.
    Schröder C; Börnert P; Aldefeld B
    J Magn Reson Imaging; 2003 Jul; 18(1):136-41. PubMed ID: 12815650
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Linear phase slope in pulse design: application to coherence transfer.
    Gershenzon NI; Skinner TE; Brutscher B; Khaneja N; Nimbalkar M; Luy B; Glaser SJ
    J Magn Reson; 2008 Jun; 192(2):235-43. PubMed ID: 18394937
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Systematic variation of off-resonance prepulses for clinical magnetization transfer contrast imaging at 0.2, 1.5, and 3.0 tesla.
    Martirosian P; Boss A; Deimling M; Kiefer B; Schraml C; Schwenzer NF; Claussen CD; Schick F
    Invest Radiol; 2008 Jan; 43(1):16-26. PubMed ID: 18097273
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Use of composite refocusing pulses to form spin echoes.
    Odedra S; Wimperis S
    J Magn Reson; 2012 Jan; 214(1):68-75. PubMed ID: 22070969
    [TBL] [Abstract][Full Text] [Related]  

  • 34. SOGGY: solvent-optimized double gradient spectroscopy for water suppression. A comparison with some existing techniques.
    Nguyen BD; Meng X; Donovan KJ; Shaka AJ
    J Magn Reson; 2007 Feb; 184(2):263-74. PubMed ID: 17126049
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Optimal control design of constant amplitude phase-modulated pulses: application to calibration-free broadband excitation.
    Skinner TE; Kobzar K; Luy B; Bendall MR; Bermel W; Khaneja N; Glaser SJ
    J Magn Reson; 2006 Apr; 179(2):241-9. PubMed ID: 16413802
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Design of broadband RF pulses with polynomial-phase response.
    Schulte RF; Henning A; Tsao J; Boesiger P; Pruessmann KP
    J Magn Reson; 2007 Jun; 186(2):167-75. PubMed ID: 17331765
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Broadband CPMG sequence with short composite refocusing pulses.
    Koroleva VD; Mandal S; Song YQ; Hürlimann MD
    J Magn Reson; 2013 May; 230():64-75. PubMed ID: 23454575
    [TBL] [Abstract][Full Text] [Related]  

  • 38. ZTE imaging with enhanced flip angle using modulated excitation.
    Schieban K; Weiger M; Hennel F; Boss A; Pruessmann KP
    Magn Reson Med; 2015 Sep; 74(3):684-93. PubMed ID: 25242318
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Practical pulse synthesis via the discrete inverse scattering transform.
    Magland J; Epstein CL
    J Magn Reson; 2005 Jan; 172(1):63-78. PubMed ID: 15589409
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Excitation of narrow frequency bands with reduced relaxation-related signal losses: methodology and preliminary applications.
    Schick F
    Magn Reson Imaging; 1999 May; 17(4):527-36. PubMed ID: 10231179
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.