141 related articles for article (PubMed ID: 22441619)
1. Use of bipolar radiofrequency in parenchymal transection of the liver, pancreas and kidney.
Pai M; Spalding D; Jiao L; Habib N
Dig Surg; 2012; 29(1):43-7. PubMed ID: 22441619
[TBL] [Abstract][Full Text] [Related]
2. Radiofrequency assisted liver resection: analysis of 604 consecutive cases.
Pai M; Frampton AE; Mikhail S; Resende V; Kornasiewicz O; Spalding DR; Jiao LR; Habib NA
Eur J Surg Oncol; 2012 Mar; 38(3):274-80. PubMed ID: 22209064
[TBL] [Abstract][Full Text] [Related]
3. Impact of radiofrequency assisted hepatectomy for reduction of transfusion requirements.
Ayav A; Bachellier P; Habib NA; Pellicci R; Tierris J; Milicevic M; Jiao LR
Am J Surg; 2007 Feb; 193(2):143-8. PubMed ID: 17236838
[TBL] [Abstract][Full Text] [Related]
4. Bloodless liver resection using radiofrequency energy.
Ayav A; Jiao LR; Habib NA
Dig Surg; 2007; 24(4):314-7. PubMed ID: 17657158
[TBL] [Abstract][Full Text] [Related]
5. InLine bipolar radiofrequency ablation device-assisted partial nephrectomy in a porcine model.
Yao P; Gunasegaram A; Ladd LA; Morris DL
ANZ J Surg; 2008 Jul; 78(7):564-7. PubMed ID: 18593411
[TBL] [Abstract][Full Text] [Related]
6. In-line radiofrequency ablation to minimize blood loss in hepatic parenchymal transection.
Haghighi KS; Wang F; King J; Daniel S; Morris DL
Am J Surg; 2005 Jul; 190(1):43-7. PubMed ID: 15972170
[TBL] [Abstract][Full Text] [Related]
7. Atypical hepatic resection technique for hepatocellular carcinoma using radiofrequency Habib™ 4X Device.
Vlad N; Lupaşcu C; Dănilă N; Georgescu Ş; Moldovanu R; Târcoveanu E
Chirurgia (Bucur); 2013; 108(1):51-5. PubMed ID: 23464770
[TBL] [Abstract][Full Text] [Related]
8. Liver resection with a new multiprobe bipolar radiofrequency device.
Ayav A; Jiao L; Dickinson R; Nicholls J; Milicevic M; Pellicci R; Bachellier P; Habib N
Arch Surg; 2008 Apr; 143(4):396-401; discussion 401. PubMed ID: 18427028
[TBL] [Abstract][Full Text] [Related]
9. Techniques of radiofrequency-assisted precoagulation in laparoscopic liver resection.
Akyildiz HY; Morris-Stiff G; Aucejo F; Fung J; Berber E
Surg Endosc; 2011 Apr; 25(4):1143-7. PubMed ID: 20844897
[TBL] [Abstract][Full Text] [Related]
10. Liver resection with bipolar radiofrequency device: Habib 4X.
Pai M; Jiao LR; Khorsandi S; Canelo R; Spalding DR; Habib NA
HPB (Oxford); 2008; 10(4):256-60. PubMed ID: 18773112
[TBL] [Abstract][Full Text] [Related]
11. Habib laparoscopic bipolar radiofrequency device: a novel way of creating an avascular resection margin in laparoscopic partial nephrectomy.
Andonian S; Adebayo A; Okeke Z; Lee BR
J Laparoendosc Adv Surg Tech A; 2008 Dec; 18(6):853-6. PubMed ID: 19105671
[TBL] [Abstract][Full Text] [Related]
12. [Clinical study of liver resection with bipolar radiofrequency device: Habib 4X].
Chen J; Dong X; Tang Z; Gao SL; Wu YL; Fang HQ
Zhonghua Yi Xue Za Zhi; 2013 Aug; 93(32):2553-6. PubMed ID: 24351595
[TBL] [Abstract][Full Text] [Related]
13. A systematic review on radiofrequency assisted laparoscopic liver resection: Challenges and window to excel.
Reccia I; Kumar J; Kusano T; Zanellato A; Draz A; Spalding D; Habib N; Pai M
Surg Oncol; 2017 Sep; 26(3):296-304. PubMed ID: 28807250
[TBL] [Abstract][Full Text] [Related]
14. Laparoscopic liver resection using radiofrequency coagulation.
Hompes D; Aerts R; Penninckx F; Topal B
Surg Endosc; 2007 Feb; 21(2):175-80. PubMed ID: 17122980
[TBL] [Abstract][Full Text] [Related]
15. Controlled study of Inline radiofrequency coagulation-assisted partial nephrectomy in sheep.
Haghighi KS; Steinke K; Hazratwala K; Kam PC; Daniel S; Morris DL
J Surg Res; 2006 Jun; 133(2):215-8. PubMed ID: 16464470
[TBL] [Abstract][Full Text] [Related]
16. Use of the Habib 4 × radiofrequency-assisted bipolar hemostatic device to avoid warm ischemia in select large partial nephrectomies: description and video of technique.
Rogers A; Thiel DD; Brisson TE; Igel TC
J Laparoendosc Adv Surg Tech A; 2011 Mar; 21(2):153-6. PubMed ID: 21284516
[TBL] [Abstract][Full Text] [Related]
17. Randomized clinical trial of radiofrequency-assisted versus clamp-crushing liver resection.
Lupo L; Gallerani A; Panzera P; Tandoi F; Di Palma G; Memeo V
Br J Surg; 2007 Mar; 94(3):287-91. PubMed ID: 17318804
[TBL] [Abstract][Full Text] [Related]
18. Minor hepatic resection using heat coagulative necrosis.
Sandonato L; Cipolla C; Fulfaro F; Lo Re G; Latteri F; Terranova A; Mastrosimone A; Bova V; Cabibbo G; Latteri MA
Am Surg; 2009 Dec; 75(12):1213-9. PubMed ID: 19999915
[TBL] [Abstract][Full Text] [Related]
19. Minor hepatic resection for hepatocellular carcinoma in cirrhotic patients: Kelly clamp crushing resection versus heat coagulative necrosis with bipolar radiofrequency device.
Sandonato L; Soresi M; Cipolla C; Bartolotta TV; Giannitrapani L; Antonucci M; Galia M; Latteri MA
Am Surg; 2011 Nov; 77(11):1490-5. PubMed ID: 22196663
[TBL] [Abstract][Full Text] [Related]
20. A radiofrequency-assisted device for bloodless rapid transection of the liver: a comparative study in a pig liver model.
Burdío F; Navarro A; Berjano E; Sousa R; Burdío JM; Güemes A; Subiró J; Gonzalez A; Cruz I; Castiella T; Tejero E; Lozano R; Grande L; de Gregorio MA
Eur J Surg Oncol; 2008 May; 34(5):599-605. PubMed ID: 17614248
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]