55 related articles for article (PubMed ID: 22442159)
1. Stroke volume obtained by electrical interrogation of the brachial artery: transbrachial electrical bioimpedance velocimetry.
Bernstein DP; Henry IC; Banet MJ; Dittrich T
Physiol Meas; 2012 Apr; 33(4):629-49. PubMed ID: 22442159
[TBL] [Abstract][Full Text] [Related]
2. Validation of stroke volume and cardiac output by electrical interrogation of the brachial artery in normals: assessment of strengths, limitations, and sources of error.
Bernstein DP; Henry IC; Lemmens HJ; Chaltas JL; DeMaria AN; Moon JB; Kahn AM
J Clin Monit Comput; 2015 Dec; 29(6):789-800. PubMed ID: 25682204
[TBL] [Abstract][Full Text] [Related]
3. Stroke volume obtained from the brachial artery using transbrachial electrical bioimpedance velocimetry.
Henry IC; Bernstein DP; Banet MJ
Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():142-5. PubMed ID: 23365852
[TBL] [Abstract][Full Text] [Related]
4. Heart-lung interactions measured by electrical impedance tomography.
Maisch S; Bohm SH; Solà J; Goepfert MS; Kubitz JC; Richter HP; Ridder J; Goetz AE; Reuter DA
Crit Care Med; 2011 Sep; 39(9):2173-6. PubMed ID: 21666450
[TBL] [Abstract][Full Text] [Related]
5. Monitoring pulmonary perfusion by electrical impedance tomography: an evaluation in a pig model.
Fagerberg A; Stenqvist O; Aneman A
Acta Anaesthesiol Scand; 2009 Feb; 53(2):152-8. PubMed ID: 19175575
[TBL] [Abstract][Full Text] [Related]
6. Assessment of Stroke Volume From Brachial Blood Pressure Using Arterial Characteristics.
Liu SH; Lin TH; Cheng DC; Wang JJ
IEEE Trans Biomed Eng; 2015 Sep; 62(9):2151-7. PubMed ID: 25807563
[TBL] [Abstract][Full Text] [Related]
7. Impact of a systolic parameter, defined as the ratio of right brachial pre-ejection period to ejection time, on the relationship between brachial-ankle pulse wave velocity and left ventricular diastolic function.
Hsu PC; Lin TH; Lee CS; Chu CY; Su HM; Voon WC; Lai WT; Sheu SH
Hypertens Res; 2011 Apr; 34(4):462-7. PubMed ID: 21228788
[TBL] [Abstract][Full Text] [Related]
8. Subcutaneous bioimpedance recording: assessment of a method for hemodynamic monitoring by implanted devices.
Venugopal D; Patterson R; Jhanjee R; McKnite S; Lurie KG; Belalcazar A; Benditt DG
J Cardiovasc Electrophysiol; 2009 Jan; 20(1):76-81. PubMed ID: 18691232
[TBL] [Abstract][Full Text] [Related]
9. A finite-element study of the effects of electrode position on the measured impedance change in impedance cardiography.
Wang Y; Haynor DR; Kim Y
IEEE Trans Biomed Eng; 2001 Dec; 48(12):1390-401. PubMed ID: 11759920
[TBL] [Abstract][Full Text] [Related]
10. [Use of the method of thoracic electric bioimpedance in medical evaluation of central hemodynamics in man].
Kravtsova EL; Voronkov IuI
Aviakosm Ekolog Med; 1995; 29(4):52-4. PubMed ID: 8664863
[TBL] [Abstract][Full Text] [Related]
11. Brachial artery differential characteristic impedance: Contributions from changes in young's modulus and diameter.
Atlas G; Li JK
Cardiovasc Eng; 2009 Mar; 9(1):11-7. PubMed ID: 19363653
[TBL] [Abstract][Full Text] [Related]
12. Assessment of central and peripheral arterial stiffness: studies indicating the need to use a combination of techniques.
Woodman RJ; Kingwell BA; Beilin LJ; Hamilton SE; Dart AM; Watts GF
Am J Hypertens; 2005 Feb; 18(2 Pt 1):249-60. PubMed ID: 15752954
[TBL] [Abstract][Full Text] [Related]
13. A comparison between the automatized impedance cardiography and pulsed-wave Doppler echocardiography methods for measurements of stroke volume (SV) and systolic time intervals (STI).
Cybulski G; Miśkiewicz Z; Szulc J; Torbicki A; Pasierski T
J Physiol Pharmacol; 1993 Sep; 44(3):251-8. PubMed ID: 8241526
[TBL] [Abstract][Full Text] [Related]
14. Transthoracic electrical bioimpedance: a non-invasive technique for the evaluation of the haemodynamic alterations in patients with liver cirrhosis.
Dazzani F; Micati M; Caraceni P; Drago GM; Domenicali M; Pacilli P; Tomassetti V; Gelonesi E; Trevisani F; Bernardi M
Dig Liver Dis; 2005 Oct; 37(10):786-92. PubMed ID: 16027054
[TBL] [Abstract][Full Text] [Related]
15. [Doppler echocardiography determination of the orifice area in aortic valve stenosis using a continuity equation].
Dennig K; Kraus F; Rudolph W
Herz; 1986 Dec; 11(6):309-17. PubMed ID: 3817722
[TBL] [Abstract][Full Text] [Related]
16. [Echocardiographic and Doppler echocardiographic characterization of left ventricular diastolic function].
Muscholl M; Dennig K; Kraus F; Rudolph W
Herz; 1990 Dec; 15(6):377-92. PubMed ID: 2279732
[TBL] [Abstract][Full Text] [Related]
17. [A comparison of cardiac stroke volume determination using the thermodilution method and PW-Doppler echocardiography for the evaluation of systolic heart function in the horse].
Stadler P; Kinkel N; Deegen E
Dtsch Tierarztl Wochenschr; 1994 Aug; 101(8):312-5. PubMed ID: 7924974
[TBL] [Abstract][Full Text] [Related]
18. Electrical velocimetry as a tool for measuring cardiac output in small infants after heart surgery.
Grollmuss O; Demontoux S; Capderou A; Serraf A; Belli E
Intensive Care Med; 2012 Jun; 38(6):1032-9. PubMed ID: 22460851
[TBL] [Abstract][Full Text] [Related]
19. [Predication of volume responsiveness by brachial artery velocity change during passive leg raising].
Zhang HM; Liu DW; Wang XT; Zhang Q; Liu Y; Long Y; Chai WZ; Zhou X; Rui X
Zhonghua Yi Xue Za Zhi; 2013 Jan; 93(3):195-9. PubMed ID: 23570593
[TBL] [Abstract][Full Text] [Related]
20. Stroke volume measurements by electrical bioimpedance and echocardiography in healthy volunteers.
Huang KC; Stoddard M; Tsueda KA; Heine MF; Thomas MH; White M; Wieman TJ
Crit Care Med; 1990 Nov; 18(11):1274-8. PubMed ID: 2225898
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]