BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

173 related articles for article (PubMed ID: 22449741)

  • 21. Failure of implantable cardioverter-defibrillator leads: a matter of lead size?
    Rordorf R; Poggio L; Savastano S; Vicentini A; Petracci B; Chieffo E; Klersy C; Landolina M
    Heart Rhythm; 2013 Feb; 10(2):184-90. PubMed ID: 23063430
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Increased rate of subacute lead complications with small-caliber implantable cardioverter-defibrillator leads.
    Ellis CR; Rottman JN
    Heart Rhythm; 2009 May; 6(5):619-24. PubMed ID: 19389648
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Prospective nationwide fluoroscopic and electrical longitudinal follow-up of recalled Riata defibrillator leads in Denmark.
    Larsen JM; Nielsen JC; Johansen JB; Haarbo J; Petersen HH; Thøgersen AM; Hjortshøj SP
    Heart Rhythm; 2014 Dec; 11(12):2141-7. PubMed ID: 25008285
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Update on small-diameter implantable cardioverter-defibrillator leads performance.
    van Rees JB; van Welsenes GH; Borleffs CJ; Thijssen J; van der Velde ET; van der Wall EE; van Erven L; Schalij MJ
    Pacing Clin Electrophysiol; 2012 Jun; 35(6):652-8. PubMed ID: 22352338
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Mechanisms, predictors, and trends of electrical failure of Riata leads.
    Cheung JW; Al-Kazaz M; Thomas G; Liu CF; Ip JE; Bender SR; Siddiqi FK; Markowitz SM; Lerman BB
    Heart Rhythm; 2013 Oct; 10(10):1453-9. PubMed ID: 23792596
    [TBL] [Abstract][Full Text] [Related]  

  • 26. User-reported abrasion-related lead failure is more common with durata compared to other implantable cardiac defibrillator leads.
    Shah AD; Hirsh DS; Langberg JJ
    Heart Rhythm; 2015 Dec; 12(12):2376-80. PubMed ID: 26165944
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Increasing lead burden correlates with externalized cables during systematic fluoroscopic screening of Riata leads.
    Moorman LP; Moorman JR; DiMarco JP; Malhotra R; Darby A; Bilchick K; Ferguson JD; Mangrum JM; Kamath S; Mason PK
    J Interv Card Electrophysiol; 2013 Jun; 37(1):63-8. PubMed ID: 23254319
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Contribution of ethylenetetrafluoroethylene (ETFE) insulation to the electrical performance of Riata® silicone leads having externalized conductors.
    Fischer A; Klehn R
    J Interv Card Electrophysiol; 2013 Aug; 37(2):141-5. PubMed ID: 23529220
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Recommendations of the Working Group of Arrhythmias of the German Society of Cardiology on the approach to patients with Riata® and Riata ST® leads (St. Jude Medical). Nucleus of the Working Group of Arrhythmias of the German Society of Cardiology].
    Israel CW; Bänsch D; Böcker D; Butter C; Chun J; Deisenhofer I; Eckardt L; Geller JC; Hanke T; Klingenheben T; Piorkowski C; Schumacher B
    Herzschrittmacherther Elektrophysiol; 2012 Jun; 23(2):107-15. PubMed ID: 22847674
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Internal insulation breaches in an implantable cardioverter-defibrillator lead with redundant conductors.
    Hauser RG; Sengupta J; Schloss EJ; Stanberry LI; Wananu MK; Abdelhadi R
    Heart Rhythm; 2019 Aug; 16(8):1215-1222. PubMed ID: 30772531
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Mechanisms of Lead Failure by Recall Status and Manufacturer: Results From the Pacemaker and Implantable Defibrillator Leads Survival Study ("PAIDLESS").
    Schwarzwald SN; Kersten DJ; Shaikh ZA; Needelman BS; Feldman AM; Germano J; Islam S; Cohen TJ
    J Invasive Cardiol; 2018 Apr; 30(4):147-151. PubMed ID: 29610446
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Longitudinal follow-up of externalized Riata leads.
    Liu J; Qin D; Rattan R; Bazaz R; Adelstein E; Jain S; Saba S
    Am J Cardiol; 2013 Nov; 112(10):1616-8. PubMed ID: 24012025
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Deaths and cardiovascular injuries due to device-assisted implantable cardioverter-defibrillator and pacemaker lead extraction.
    Hauser RG; Katsiyiannis WT; Gornick CC; Almquist AK; Kallinen LM
    Europace; 2010 Mar; 12(3):395-401. PubMed ID: 19946113
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [National Consultant in Cardiology Experts' Group Guidelines on dealing with patients implanted with some St. Jude Medical Riata and Riata ST leads].
    Mitkowski P; Grabowski M; Kowalski O; Kutarski A; Mojkowski W; Przybylski A; Sterliński M; Trusz-Gluza M; Opolski G
    Kardiol Pol; 2014; 72(6):576-82. PubMed ID: 24961459
    [TBL] [Abstract][Full Text] [Related]  

  • 35. To the editor--response to "Deaths caused by the failure of Riata and Riata ST implantable cardioverter-defibrillator leads," by Hauser et al.
    Carlson MD
    Heart Rhythm; 2012 Aug; 9(8):1342-3. PubMed ID: 22575225
    [No Abstract]   [Full Text] [Related]  

  • 36. Transvenous extraction of implantable cardioverter-defibrillator leads under advisory--a comparison of Riata, Sprint Fidelis, and non-recalled implantable cardioverter-defibrillator leads.
    Brunner MP; Cronin EM; Jacob J; Duarte VE; Tarakji KG; Martin DO; Callahan T; Borek PP; Cantillon DJ; Niebauer MJ; Saliba WI; Kanj M; Wazni O; Baranowski B; Wilkoff BL
    Heart Rhythm; 2013 Oct; 10(10):1444-50. PubMed ID: 23816440
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Comparison of lead failure manifestation of Biotronik Linox with St. Jude Medical Riata and Medtronic Sprint Fidelis lead.
    Lam A; Buehler S; Goulouti E; Sweda R; Haeberlin A; Medeiros-Domingo A; Servatius H; Seiler J; Baldinger S; Noti F; Tanner H; Roten L
    J Interv Card Electrophysiol; 2019 Mar; 54(2):161-170. PubMed ID: 30471050
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Lead thrombi associated with externalized cables on Riata ICD leads: a case series.
    Goyal SK; Ellis CR; Rottman JN; Whalen SP
    J Cardiovasc Electrophysiol; 2013 Sep; 24(9):1047-50. PubMed ID: 23577693
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Insulation defects in Riata implantable cardioverter-defibrillator leads.
    Sato A; Chinushi M; Iijima K; Izumi D; Furushima H
    Intern Med; 2012; 51(19):2689-94. PubMed ID: 23037457
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Does size really matter? A comparison of the Riata lead family based on size and its relation to performance.
    Corbisiero R; Armbruster R
    Pacing Clin Electrophysiol; 2008 Jun; 31(6):722-6. PubMed ID: 18507545
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.