These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

48 related articles for article (PubMed ID: 22457252)

  • 1. Modelling for crossed Kirschner wire fixation.
    Lohn JW; Hussain SA; Belcher HJ
    J Hand Surg Eur Vol; 2012 Nov; 37(9):900-1. PubMed ID: 22457252
    [No Abstract]   [Full Text] [Related]  

  • 2. [Current treatment concepts for joint injuries of the hand and their consequences].
    Schädel-Höpfner M
    Unfallchirurg; 2014 Apr; 117(4):289-90. PubMed ID: 24700080
    [No Abstract]   [Full Text] [Related]  

  • 3. Buried Kirschner wire fixation in digital fusion.
    Creighton RE; Blustein SM
    J Foot Ankle Surg; 1995; 34(6):567-70; discussion 595. PubMed ID: 8646209
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Resorbable PDS splints in fracture stabilization and for arthrodeses of the hand].
    Wüstner MC; Partecke BD; Buck-Gramcko D
    Handchir Mikrochir Plast Chir; 1986 Sep; 18(5):298-301. PubMed ID: 3095201
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Internal fixation for small joint arthrodeses in the hand. The interphalangeal joints.
    Leibovic SJ
    Hand Clin; 1997 Nov; 13(4):601-13. PubMed ID: 9403296
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Case-control study on therapeutic effects between Kirschner wire fixation after early bebridement and staged plate fixation in the treatment of open calcaneal fractures].
    Zhu YZ; Li YQ; Wu F; Zhang HN; Wen JQ; Bao HS
    Zhongguo Gu Shang; 2012 Feb; 25(2):103-8. PubMed ID: 22577710
    [TBL] [Abstract][Full Text] [Related]  

  • 7. SmartToe® implant compared with Kirschner wire fixation for hammer digit corrective surgery: a review of 28 patients.
    Angirasa AK; Barrett MJ; Silvester D
    J Foot Ankle Surg; 2012; 51(6):711-3. PubMed ID: 22884907
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biomechanical comparison of three fixation techniques used for four-corner arthrodesis.
    Kraisarin J; Dennison DG; Berglund LJ; An KN; Shin AY
    J Hand Surg Eur Vol; 2011 Sep; 36(7):560-7. PubMed ID: 21636620
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Triple arthrodesis using external ring fixation and arched-wire compression.
    Key JJ
    J Am Podiatr Med Assoc; 2004; 94(4):412; author reply 412. PubMed ID: 15266004
    [No Abstract]   [Full Text] [Related]  

  • 10. Small joint arthrodesis.
    Bishop AT
    Hand Clin; 1993 Nov; 9(4):683-9. PubMed ID: 8300737
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Arthrodesis of the small joints of the hand with rigid internal fixation (author's transl)].
    Rupnik J; Csorba E
    Magy Traumatol Orthop Helyreallito Seb; 1980; 23(2):140-6. PubMed ID: 6114208
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Single Kirschner wire fixation in triple arthrodesis.
    HASLAM ET; WICKSTROM JK
    South Med J; 1955 Jul; 48(7):767-9. PubMed ID: 14396564
    [No Abstract]   [Full Text] [Related]  

  • 13. [Microbore wires in osseous tendon ruptures of the distal finger joint].
    Wozasek GE; Moser KD; Haller H
    Handchir Mikrochir Plast Chir; 1987 May; 19(3):168-70. PubMed ID: 3596373
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Case-control study on therapeutic effects of different fixation methods with three Kirschners wires for the treatment of humeral supracondylar fractures].
    Liao JX; Wang JW; Zhang AG; Cai JP; Yan SH; Zhu GH
    Zhongguo Gu Shang; 2011 Aug; 24(8):625-8. PubMed ID: 21928663
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Less-invasive stabilization of rib fractures by intramedullary fixation: a biomechanical evaluation.
    Bottlang M; Helzel I; Long W; Fitzpatrick D; Madey S
    J Trauma; 2010 May; 68(5):1218-24. PubMed ID: 20068479
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The use of Kirschner wire fixation in forefoot surgery.
    Reichert K; Caneva RG
    J Foot Surg; 1983; 22(3):218-21. PubMed ID: 6619519
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Four-point bending strength of transverse osteotomies stabilized with various Kirschner wire and tension wire band configurations.
    Pehlivan O; Kiral A; Mahirogullari M; Koksal O; Kaplan H
    J Hand Surg Br; 2005 Aug; 30(4):428-31. PubMed ID: 15935530
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Toe fusion using Kirschner wire. A study of the postoperative infection rate and related problems.
    Reece AT; Stone MH; Young AB
    J R Coll Surg Edinb; 1987 Jun; 32(3):158-9. PubMed ID: 3656240
    [No Abstract]   [Full Text] [Related]  

  • 19. One century of Kirschner wires and Kirschner wire insertion techniques: a historical review.
    Franssen BB; Schuurman AH; Van der Molen AM; Kon M
    Acta Orthop Belg; 2010 Feb; 76(1):1-6. PubMed ID: 20306956
    [TBL] [Abstract][Full Text] [Related]  

  • 20. First metatarsophalangeal joint arthrodesis: current fixation options.
    Moon JL; McGlamry MC
    Clin Podiatr Med Surg; 2011 Apr; 28(2):405-19, ix. PubMed ID: 21669346
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 3.