114 related articles for article (PubMed ID: 22462326)
1. Nerve sparing sutureless total thyroidectomy. Preliminary study.
Parmeggiani D; De Falco M; Avenia N; Sanguinetti A; Fiore A; Docimo G; Ambrosino P; Madonna I; Peltrini R; Parmeggiani U
Ann Ital Chir; 2012; 83(2):91-6. PubMed ID: 22462326
[TBL] [Abstract][Full Text] [Related]
2. NIM vs Neurosign in nerve sparing total thyroidectomy. Multicentric experience.
Parmeggiani D; De Falco M; Avenia N; Sanguinetti A; Fiore A; Gubitosi A; Madonna I; Peltrini R; Ambrosino P; Parmeggiani U
Ann Ital Chir; 2012; 83(3):233-8. PubMed ID: 22610121
[TBL] [Abstract][Full Text] [Related]
3. Major complications in thyroid surgery: utility of bipolar vessel sealing (Ligasure Precise).
Parmeggiani U; Avenia N; De Falco M; Parmeggiani D; Pisaniello D; d'Ajello M; Monacelli M; Calzolari F; Sanguinetti A; Sperlongano P
G Chir; 2005 Oct; 26(10):387-94. PubMed ID: 16371192
[TBL] [Abstract][Full Text] [Related]
4. LigaSure vs clamp-and-tie technique to achieve hemostasis in total thyroidectomy for benign multinodular goiter: a prospective randomized study.
Saint Marc O; Cogliandolo A; Piquard A; Famà F; Pidoto RR
Arch Surg; 2007 Feb; 142(2):150-6; discussion 157. PubMed ID: 17309966
[TBL] [Abstract][Full Text] [Related]
5. Recurrent laryngeal nerve injury and preservation in thyroidectomy.
Aytac B; Karamercan A
Saudi Med J; 2005 Nov; 26(11):1746-9. PubMed ID: 16311659
[TBL] [Abstract][Full Text] [Related]
6. Ultrasonic harmonic scalpel in total thyroidectomies.
Yildirim O; Umit T; Ebru M; Bulent U; Belma K; Betul B; Mete D; Omer C
Adv Ther; 2008 Mar; 25(3):260-5. PubMed ID: 18324377
[TBL] [Abstract][Full Text] [Related]
7. [Complications of total thyroidectomy: incidence, prevention and treatment].
Rosato L; Avenia N; De Palma M; Gulino G; Nasi PG; Pezzullo L
Chir Ital; 2002; 54(5):635-42. PubMed ID: 12469460
[TBL] [Abstract][Full Text] [Related]
8. A randomized, prospective, parallel group study comparing the Harmonic Scalpel to electrocautery in thyroidectomy.
Cordón C; Fajardo R; Ramírez J; Herrera MF
Surgery; 2005 Mar; 137(3):337-41. PubMed ID: 15746789
[TBL] [Abstract][Full Text] [Related]
9. [Hemostasis and bleeding control in thyroid surgery using electrothermal system (Ligasure): our experience in 317 patients].
Ashkenazi D; Mazzawi S; Rakover Y
Harefuah; 2006 Aug; 145(8):561-4, 632, 631. PubMed ID: 16983836
[TBL] [Abstract][Full Text] [Related]
10. LigaSure versus clamp-and-tie thyroidectomy for benign nodular disease.
Petrakis IE; Kogerakis NE; Lasithiotakis KG; Vrachassotakis N; Chalkiadakis GE
Head Neck; 2004 Oct; 26(10):903-9. PubMed ID: 15390199
[TBL] [Abstract][Full Text] [Related]
11. [Bipolar electrothermic coagulation (ligasure bipolar vessel sealing system) in thyroid surgery].
Sandonato L; Cipolla C; Graceffa G; Fricano S; Li Petri S; Prinzi G; Latteri S; Latteri MA
Chir Ital; 2003; 55(3):411-5. PubMed ID: 12872578
[TBL] [Abstract][Full Text] [Related]
12. [Early complications in surgical treatment of thyroid diseases: analysis of 2100 patients].
Ignjatović M; Cuk V; Ozegović A; Cerović S; Kostić Z; Romić P
Acta Chir Iugosl; 2003; 50(3):155-75. PubMed ID: 15179773
[TBL] [Abstract][Full Text] [Related]
13. Thyroidectomy with ultrasonic dissector: a multicentric experience.
D'Ajello F; Cirocchi R; Docimo G; Catania A; Ardito G; Rosato L; Avenia N
G Chir; 2010; 31(6-7):289-92. PubMed ID: 20646373
[TBL] [Abstract][Full Text] [Related]
14. [Thyroidectomy using the intra-operative neuromonitoring and the surgeon's confidence].
Sacco R; Lucisano AM; Innaro N; Cardona R; Lazzaro F; Tomaino G; Gervasi R; Orsini V
Ann Ital Chir; 2012; 83(2):97-101. PubMed ID: 22462327
[TBL] [Abstract][Full Text] [Related]
15. LigaSure versus clamp-and-tie in thyroidectomy: a single-center experience.
Cakabay B; Sevinç MM; Gömceli I; Yenidogan E; Ulkü A; Koç S
Adv Ther; 2009 Nov; 26(11):1035-41. PubMed ID: 20024679
[TBL] [Abstract][Full Text] [Related]
16. [Continuous monitoring of the recurrent laryngeal nerve].
Lamadé W; Brandner R; Brauer M; Hund E; Klar E; Herfarth C
Langenbecks Arch Chir Suppl Kongressbd; 1998; 115():1055-7. PubMed ID: 9931788
[TBL] [Abstract][Full Text] [Related]
17. [Morbidity and costs in complete thyroidectomies. Improvement in Value of the Process by a change in the management].
Gómez Palacios A; Barrios B; Gutiérrez MT; Expósito A; Gómez Zabala J; Roca B; Pérez de Villarreal P; Ruiz S; Escobar A; Iturburu I; Méndez J
Rev Calid Asist; 2012; 27(3):161-8. PubMed ID: 22137200
[TBL] [Abstract][Full Text] [Related]
18. What is the learning curve for intraoperative neuromonitoring in thyroid surgery?
Dionigi G; Bacuzzi A; Boni L; Rovera F; Dionigi R
Int J Surg; 2008; 6 Suppl 1():S7-12. PubMed ID: 19117822
[TBL] [Abstract][Full Text] [Related]
19. Use of a diathermy system in thyroid surgery.
Kiriakopoulos A; Dimitrios T; Dimitrios L
Arch Surg; 2004 Sep; 139(9):997-1000. PubMed ID: 15381620
[TBL] [Abstract][Full Text] [Related]
20. Complications of thyroidectomy and parathyroidectomy in the rural community hospital setting.
Richmond BK; Eads K; Flaherty S; Belcher M; Runyon D
Am Surg; 2007 Apr; 73(4):332-6. PubMed ID: 17439023
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]