132 related articles for article (PubMed ID: 22470846)
1. Measurement of forces generated during distraction of growing-rods in early onset scoliosis.
Teli M; Grava G; Solomon V; Andreoletti G; Grismondi E; Meswania J
World J Orthop; 2012 Feb; 3(2):15-9. PubMed ID: 22470846
[TBL] [Abstract][Full Text] [Related]
2. In vivo distraction force and length measurements of growing rods: which factors influence the ability to lengthen?
Noordeen HM; Shah SA; Elsebaie HB; Garrido E; Farooq N; Al-Mukhtar M
Spine (Phila Pa 1976); 2011 Dec; 36(26):2299-303. PubMed ID: 21494191
[TBL] [Abstract][Full Text] [Related]
3. Quantitative Characteristics of Consecutive Lengthening Episodes in Early-onset Scoliosis (EOS) Patients With Dual Growth Rods.
Agarwal A; Goswami A; Vijayaraghavan GP; Srivastava A; Kandwal P; Nagaraja UB; Goel VK; Agarwal AK; Jayaswal A
Spine (Phila Pa 1976); 2019 Mar; 44(6):397-403. PubMed ID: 30095792
[TBL] [Abstract][Full Text] [Related]
4. Standard and magnetically controlled growing rods for the treatment of early onset scoliosis.
Helenius IJ
Ann Transl Med; 2020 Jan; 8(2):26. PubMed ID: 32055617
[TBL] [Abstract][Full Text] [Related]
5. Magnetically Controlled Growing Rods for the Management of Early-onset Scoliosis: A Preliminary Report.
La Rosa G; Oggiano L; Ruzzini L
J Pediatr Orthop; 2017 Mar; 37(2):79-85. PubMed ID: 26192879
[TBL] [Abstract][Full Text] [Related]
6. Results of the spine-to-rib-cage distraction in the treatment of early onset scoliosis.
Teli M; Lovi A; Brayda-Bruno M
Indian J Orthop; 2010 Jan; 44(1):23-7. PubMed ID: 20165673
[TBL] [Abstract][Full Text] [Related]
7. Clinically relevant finite element technique based protocol to evaluate growing rods for early onset scoliosis correction.
Shekouhi N; Dick D; Baechle MW; Kaeley DK; Goel VK; Serhan H; Rawlinson J; Shaw D
JOR Spine; 2020 Sep; 3(3):e1119. PubMed ID: 33015580
[TBL] [Abstract][Full Text] [Related]
8. Distraction magnitude and frequency affects the outcome in juvenile idiopathic patients with growth rods: finite element study using a representative scoliotic spine model.
Agarwal A; Zakeri A; Agarwal AK; Jayaswal A; Goel VK
Spine J; 2015 Aug; 15(8):1848-55. PubMed ID: 25862502
[TBL] [Abstract][Full Text] [Related]
9. Spring distraction system for dynamic growth guidance of early onset scoliosis: two-year prospective follow-up of 24 patients.
Lemans JVC; Wijdicks SPJ; Castelein RM; Kruyt MC
Spine J; 2021 Apr; 21(4):671-681. PubMed ID: 33221513
[TBL] [Abstract][Full Text] [Related]
10. Kinematic and biomechanical responses of the spine to distraction surgery in children with early onset scoliosis: A 3-D finite element analysis.
Pei B; Lu D; Wu X; Xu Y; Ma C; Wu S
Front Bioeng Biotechnol; 2022; 10():933341. PubMed ID: 35910017
[TBL] [Abstract][Full Text] [Related]
11. Quantifying the 'law of diminishing returns' in magnetically controlled growing rods.
Ahmad A; Subramanian T; Panteliadis P; Wilson-Macdonald J; Rothenfluh DA; Nnadi C
Bone Joint J; 2017 Dec; 99-B(12):1658-1664. PubMed ID: 29212690
[TBL] [Abstract][Full Text] [Related]
12. Growing rods for spinal deformity: characterizing consensus and variation in current use.
Yang JS; McElroy MJ; Akbarnia BA; Salari P; Oliveira D; Thompson GH; Emans JB; Yazici M; Skaggs DL; Shah SA; Kostial PN; Sponseller PD
J Pediatr Orthop; 2010; 30(3):264-70. PubMed ID: 20357593
[TBL] [Abstract][Full Text] [Related]
13. Some Connectors in Distraction-based Growing Rods Fail More Than Others.
Lee C; Myung KS; Skaggs DL
Spine Deform; 2013 Mar; 1(2):148-156. PubMed ID: 27927432
[TBL] [Abstract][Full Text] [Related]
14. Radiological and clinical assessment of the distraction achieved with remotely expandable growing rods in early onset scoliosis.
Rolton D; Thakar C; Wilson-MacDonald J; Nnadi C
Eur Spine J; 2016 Oct; 25(10):3371-3376. PubMed ID: 26358257
[TBL] [Abstract][Full Text] [Related]
15. Traditional growing rod versus magnetically controlled growing rod for treatment of early onset scoliosis: Cost analysis from implantation till skeletal maturity.
Wong CKH; Cheung JPY; Cheung PWH; Lam CLK; Cheung KMC
J Orthop Surg (Hong Kong); 2017; 25(2):2309499017705022. PubMed ID: 28481128
[TBL] [Abstract][Full Text] [Related]
16. Use of a distraction-to-stall lengthening procedure in magnetically controlled growing rods: A single-center cohort study.
Dahl B; Dragsted C; Ohrt-Nissen S; Andersen T; Gehrchen M
J Orthop Surg (Hong Kong); 2018; 26(2):2309499018779833. PubMed ID: 29871534
[TBL] [Abstract][Full Text] [Related]
17. Treatment of early-onset scoliosis with a hybrid of a concave magnetic driver (magnetic controlled growth rod) and a contralateral passive sliding rod construct with apical control: preliminary report on 17 cases.
Skov ST; Wijdicks SPJ; Bünger C; Castelein RM; Li H; Kruyt MC
Spine J; 2018 Jan; 18(1):122-129. PubMed ID: 28687252
[TBL] [Abstract][Full Text] [Related]
18. A six-year observational study of 31 children with early-onset scoliosis treated using magnetically controlled growing rods with a minimum follow-up of two years.
Subramanian T; Ahmad A; Mardare DM; Kieser DC; Mayers D; Nnadi C
Bone Joint J; 2018 Sep; 100-B(9):1187-1200. PubMed ID: 30168755
[TBL] [Abstract][Full Text] [Related]
19. Staged Growing Rods With Preimplantation of Spinal Anchors for Complex Early Onset Scoliosis.
Gomez JA; Grzywna A; Hanstein R; Emans JB; Hresko MT; Hedequist D; Karlin LI; Glotzbecker MP
J Pediatr Orthop; 2017 Dec; 37(8):e606-e611. PubMed ID: 28244928
[TBL] [Abstract][Full Text] [Related]
20. Implant Complications After Magnetically Controlled Growing Rods for Early Onset Scoliosis: A Multicenter Retrospective Review.
Choi E; Yaszay B; Mundis G; Hosseini P; Pawelek J; Alanay A; Berk H; Cheung K; Demirkiran G; Ferguson J; Greggi T; Helenius I; La Rosa G; Senkoylu A; Akbarnia BA
J Pediatr Orthop; 2017 Dec; 37(8):e588-e592. PubMed ID: 27328123
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]