BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

396 related articles for article (PubMed ID: 22471790)

  • 21. [Application of plasma sprayed zirconia coating in dental implant: study in implant].
    Huang ZF; Wang ZF; Li CH; Hao D; Lan J
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2018 Apr; 53(4):264-270. PubMed ID: 29690698
    [No Abstract]   [Full Text] [Related]  

  • 22. Osseointegration of one-piece zirconia implants compared with a titanium implant of identical design: a histomorphometric study in the dog.
    Koch FP; Weng D; Krämer S; Biesterfeld S; Jahn-Eimermacher A; Wagner W
    Clin Oral Implants Res; 2010 Mar; 21(3):350-6. PubMed ID: 20074240
    [TBL] [Abstract][Full Text] [Related]  

  • 23. The cytocompatibility and osseointegration of the Ti implants with XPEED® surfaces.
    Lee SY; Yang DJ; Yeo S; An HW; Ryoo KH; Park KB
    Clin Oral Implants Res; 2012 Nov; 23(11):1283-9. PubMed ID: 22093072
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparison of osseointegration on various implant surfaces after bacterial contamination and cleaning: a rabbit study.
    Yuan K; Chan YJ; Kung KC; Lee TM
    Int J Oral Maxillofac Implants; 2014; 29(1):32-40. PubMed ID: 24451851
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Biological responses of anodized titanium implants under different current voltages.
    Choi JW; Heo SJ; Koak JY; Kim SK; Lim YJ; Kim SH; Lee JB
    J Oral Rehabil; 2006 Dec; 33(12):889-97. PubMed ID: 17168931
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effect of Zirconia Dental Implant Surfaces on Bone Integration: A Systematic Review and Meta-Analysis.
    Hafezeqoran A; Koodaryan R
    Biomed Res Int; 2017; 2017():9246721. PubMed ID: 28299337
    [No Abstract]   [Full Text] [Related]  

  • 27. Biomechanical evaluation of a microstructured zirconia implant by a removal torque comparison with a standard Ti-SLA implant.
    Bormann KH; Gellrich NC; Kniha H; Dard M; Wieland M; Gahlert M
    Clin Oral Implants Res; 2012 Oct; 23(10):1210-6. PubMed ID: 22092587
    [TBL] [Abstract][Full Text] [Related]  

  • 28. The removal torque of titanium screw inserted in rabbit tibia treated by dual acid etching.
    Cho SA; Park KT
    Biomaterials; 2003 Sep; 24(20):3611-7. PubMed ID: 12809791
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Osseointegration of zirconia and titanium implants in a rabbit tibiae model evaluated by microtomography, histomorphometry and fluorochrome labeling analyses.
    Martins R; Cestari TM; Arantes RVN; Santos PS; Taga R; Carbonari MJ; Oliveira RC
    J Periodontal Res; 2018 Apr; 53(2):210-221. PubMed ID: 29044523
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Biomechanical comparison of different surface modifications for dental implants.
    Ferguson SJ; Langhoff JD; Voelter K; von Rechenberg B; Scharnweber D; Bierbaum S; Schnabelrauch M; Kautz AR; Frauchiger VM; Mueller TL; van Lenthe GH; Schlottig F
    Int J Oral Maxillofac Implants; 2008; 23(6):1037-46. PubMed ID: 19216272
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Biomechanical Evaluation of Nano-Zirconia Coatings on Ti-6Al-7Nb Implant Screws in Rabbit Tibias.
    Hamad TI; Fatalla AA; Waheed AS; Azzawi ZGM; Cao YG; Song K
    Curr Med Sci; 2018 Jun; 38(3):530-537. PubMed ID: 30074223
    [TBL] [Abstract][Full Text] [Related]  

  • 32. In vivo monitoring of the bone healing process around different titanium alloy implant surfaces placed into fresh extraction sockets.
    Colombo JS; Satoshi S; Okazaki J; Crean SJ; Sloan AJ; Waddington RJ
    J Dent; 2012 Apr; 40(4):338-46. PubMed ID: 22307025
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Mechanical anchorage and peri-implant bone formation of surface-modified zirconia in minipigs.
    Schliephake H; Hefti T; Schlottig F; Gédet P; Staedt H
    J Clin Periodontol; 2010 Sep; 37(9):818-28. PubMed ID: 20573183
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Removal torque and histomorphometric evaluation of bioceramic grit-blasted/acid-etched and dual acid-etched implant surfaces: an experimental study in dogs.
    Marin C; Granato R; Suzuki M; Gil JN; Piattelli A; Coelho PG
    J Periodontol; 2008 Oct; 79(10):1942-9. PubMed ID: 18834250
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Zirconia with laser-modified microgrooved surface vs. titanium implants covered with melatonin stimulates bone formation. Experimental study in tibia rabbits.
    Calvo-Guirado JL; Aguilar Salvatierra A; Gargallo-Albiol J; Delgado-Ruiz RA; Maté Sanchez JE; Satorres-Nieto M
    Clin Oral Implants Res; 2015 Dec; 26(12):1421-9. PubMed ID: 25155996
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Importance of Ca(2+) modifications for osseointegration of smooth and moderately rough anodized titanium implants - a removal torque and histological evaluation in rabbit.
    Fröjd V; Wennerberg A; Franke Stenport V
    Clin Implant Dent Relat Res; 2012 Oct; 14(5):737-45. PubMed ID: 20977616
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Biological performance of chemical hydroxyapatite coating associated with implant surface modification by laser beam: biomechanical study in rabbit tibias.
    Faeda RS; Tavares HS; Sartori R; Guastaldi AC; Marcantonio E
    J Oral Maxillofac Surg; 2009 Aug; 67(8):1706-15. PubMed ID: 19615586
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Osseointegration enhanced by chemical etching of the titanium surface. A torque removal study in the rabbit.
    Klokkevold PR; Nishimura RD; Adachi M; Caputo A
    Clin Oral Implants Res; 1997 Dec; 8(6):442-7. PubMed ID: 9555202
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Osseointegration of titanium, titanium alloy and zirconia dental implants: current knowledge and open questions.
    Bosshardt DD; Chappuis V; Buser D
    Periodontol 2000; 2017 Feb; 73(1):22-40. PubMed ID: 28000277
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Evaluation of a novel calcium phosphate-coated titanium porous oxide implant surface: a study in rabbits.
    Poulos NM; Rodriguez NA; Lee J; Rueggeberg FA; Schüpbach P; Hall J; Susin C; Wikesjö UM
    Int J Oral Maxillofac Implants; 2011; 26(4):731-8. PubMed ID: 21841981
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 20.