These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

87 related articles for article (PubMed ID: 22477516)

  • 1. Aortic dissection after open repair of an infrarenal aortic aneurysm.
    Lorenzo LR; Villegas AR; Mestre XM; Gonzalez ZM; Castellote C
    Int J Angiol; 2009; 18(3):143-6. PubMed ID: 22477516
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Infrarenal aortic repair with or without false lumen intentional placement of endografts for hybrid management of complex aortic dissection.
    Quinones-Baldrich WJ; Saleem T; Oskowitz A
    J Vasc Surg; 2018 Jul; 68(1):46-54. PubMed ID: 29398314
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Surgery of abdominal aorta with horseshoe kidney].
    Lotina SL; Davidović LB; Kostić DM; Velimirović DV; Petrović PLj; Perisić-Savić MV; KovacevićN S
    Srp Arh Celok Lek; 1997; 125(1-2):36-44. PubMed ID: 17974353
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Change of paradigms in the surgical treatment of complex thoracic aortic disease].
    Herold U; Tsagakis K; Kamler M; Massoudy P; Assenmacher E; Eggebrecht H; Buck T; Jakob H
    Herz; 2006 Aug; 31(5):434-42. PubMed ID: 16944063
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A rare case of an acute type B aortic dissection contained infrarenal rupture of the false lumen after prior endovascular abdominal aneurysm repair.
    Streck E; Souri Y; Hyhlik-Dürr A
    J Vasc Surg Cases Innov Tech; 2024 Feb; 10(1):101366. PubMed ID: 38130360
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Influence of fixation mechanism on changes of the supra- and infrarenal segment of the aorta after endovascular treatment of infrarenal aortic aneurysm].
    Oberhuber A; Schwarz A; Hoffmann M; Klass O; Schelzig H; Orend KH; Mühling B
    Zentralbl Chir; 2010 Oct; 135(5):433-7. PubMed ID: 20976646
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Endovascular repair of abdominal aortic aneurysm with severely angulated neck and tortuous artery access: case report and literature review.
    Zeng Q; Huang L; Huang X; Peng M
    BMC Surg; 2015 Mar; 15():20. PubMed ID: 25887163
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Treatment of type II endoleaks associated with left subclavian artery coverage during thoracic aortic stent grafting.
    Peterson MD; Wheatley GH; Kpodonu J; Williams JP; Ramaiah VG; Rodriguez-Lopez JA; Diethrich EB
    J Thorac Cardiovasc Surg; 2008 Nov; 136(5):1193-9. PubMed ID: 19026802
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Endovascular repair of paraanastomotic aneurysms after previous open aortic prosthetic reconstruction.
    van Herwaarden JA; Waasdorp EJ; Bendermacher BL; van den Berg JC; Teijink JA; Moll FL
    Ann Vasc Surg; 2004 May; 18(3):280-6. PubMed ID: 15354628
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Anatomic exclusion from endovascular repair of thoracic aortic aneurysm.
    Jackson BM; Carpenter JP; Fairman RM; Moser GW; Pochettino A; Woo EY; Bavaria JE
    J Vasc Surg; 2007 Apr; 45(4):662-6. PubMed ID: 17350215
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The midterm results of stent graft treatment of thoracic aortic injuries.
    McPhee JT; Asham EH; Rohrer MJ; Singh MJ; Wong G; Vorhies RW; Nelson PR; Cutler BS
    J Surg Res; 2007 Apr; 138(2):181-8. PubMed ID: 17292414
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Clinical trial outcomes and thoracic aortic morphometry after one year with the Valiant Navion stent graft system.
    Verzini F; Desai N; Arko FR; Panneton JM; Thaveau F; Dagenais F; Guo J; Azizzadeh A
    J Vasc Surg; 2021 Aug; 74(2):569-578.e3. PubMed ID: 33592295
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Concomitant true and false lumen "parallel thoracic endovascular aortic repair" as an endovascular alternative to open arch/descending aortic reconstruction for chronic DeBakey type I dissection with aneurysmal degeneration.
    Buddemeyer KM; Eudailey KW; Pearce BJ; Beck AW
    J Vasc Surg Cases Innov Tech; 2019 Dec; 5(4):557-560. PubMed ID: 31867472
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The role of aortic neck dilation and elongation in the etiology of stent graft migration after endovascular abdominal aortic aneurysm repair with a passive fixation device.
    Litwinski RA; Donayre CE; Chow SL; Song TK; Kopchok G; Walot I; White RA
    J Vasc Surg; 2006 Dec; 44(6):1176-81. PubMed ID: 17145418
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Safety and durability of infrarenal aorta as distal landing zone in fenestrated or branched endograft repair for thoracoabdominal aneurysm.
    Law Y; Kölbel T; Rohlffs F; Behrendt C; Heidemann F; Debus ES; Tsilimparis N
    J Vasc Surg; 2019 Feb; 69(2):334-340. PubMed ID: 29945837
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Complex thoracoabdominal aortic aneurysms: endovascular exclusion with visceral revascularization.
    Black SA; Wolfe JH; Clark M; Hamady M; Cheshire NJ; Jenkins MP
    J Vasc Surg; 2006 Jun; 43(6):1081-9; discussion 1089. PubMed ID: 16765218
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Long-term results after standard endovascular aneurysm repair with the Endurant and Excluder stent grafts.
    Oliveira-Pinto J; Oliveira NFG; Bastos-Gonçalves FM; Hoeks S; Rijn MJV; Raa ST; Mansilha A; Verhagen HJM
    J Vasc Surg; 2020 Jan; 71(1):64-74. PubMed ID: 31147134
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Lobato technique for acute type B aortic dissection complicated by thoracoabdominal aortic aneurysm and total true lumen occlusion of the infrarenal aorta.
    Lobato AC; Riscado L; Simão JR; Meirelles G; Accioly LA; Camacho-Lobato L
    J Vasc Surg Cases Innov Tech; 2022 Sep; 8(3):514-519. PubMed ID: 36072298
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Surgical Repair of Abdominal Aortic and Renal Artery Aneurysms in Takayasu's Arteritis.
    Wetstein PJ; Clark ME; Cafasso DE; Golarz SR; Ayubi FS; Kellicut DC
    Hawaii J Med Public Health; 2016 Jan; 75(1):4-7. PubMed ID: 26870600
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Total endovascular repair of an intraoperative stent-graft deployed in the false lumen of Stanford type A aortic dissection: A case report.
    Li XR; Tong YH; Li XQ; Liu CJ; Liu C; Liu Z
    World J Clin Cases; 2020 Mar; 8(5):954-962. PubMed ID: 32190633
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.