These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

98 related articles for article (PubMed ID: 2247925)

  • 1. Methylene blue and pulse oximeter readings in a patient undergoing transurethral procedure.
    Schleifer WF; Chapin JW; Cuka DJ; Taylor RJ
    Urology; 1990 Dec; 36(6):537-8. PubMed ID: 2247925
    [No Abstract]   [Full Text] [Related]  

  • 2. False indication of arterial oxygen desaturation and methemoglobinemia following injection of methylene blue in urological surgery.
    Kirlangitis JJ; Middaugh RE; Zablocki A; Rodriquez F
    Mil Med; 1990 Jun; 155(6):260-2. PubMed ID: 2122301
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Patent blue sentinel node mapping in cervical cancer patients may lead to decreased pulse oximeter readings and positive methaemoglobin results.
    Kieckbusch H; Coldewey SM; Hollenhorst J; Haeseler G; Hillemanns P; Hertel H
    Eur J Anaesthesiol; 2008 May; 25(5):365-8. PubMed ID: 18272013
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Intraoperative decrease in pulse oximeter readings following injection of isosulfan blue.
    Hoskin RW; Granger R
    Can J Anaesth; 2001 Jan; 48(1):38-40. PubMed ID: 11212047
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pulse oximetry and methylene blue.
    Robinson DN; McFadzean WA
    Anaesthesia; 1990 Oct; 45(10):884-5. PubMed ID: 2240510
    [No Abstract]   [Full Text] [Related]  

  • 6. Prolonged decrease of regional cerebral saturation readings with the INVOS device after continuous intravenous methylene blue administration.
    Mittnacht AJ
    Anesth Analg; 2008 Apr; 106(4):1327; discussion 1327. PubMed ID: 18349217
    [No Abstract]   [Full Text] [Related]  

  • 7. Effects of intravenously administered dyes on pulse oximetry readings.
    Scheller MS; Unger RJ; Kelner MJ
    Anesthesiology; 1986 Nov; 65(5):550-2. PubMed ID: 3777490
    [No Abstract]   [Full Text] [Related]  

  • 8. [False decrease in pulse oximetry readings due to patent blue in a patient with breast cancer].
    Murakami T; Kayo R; Kajita I; Cho S; Saito H
    Masui; 2003 Aug; 52(8):909-11. PubMed ID: 13677292
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fluorescent light interferes with pulse oximetry.
    Amar D; Neidzwski J; Wald A; Finck AD
    J Clin Monit; 1989 Apr; 5(2):135-6. PubMed ID: 2656924
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of methylene blue on the absorbance of solutions of haemoglobin.
    Gorman ES; Shnider MR
    Br J Anaesth; 1988 Mar; 60(4):439-44. PubMed ID: 3355740
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Methylene blue and pulse oximetry readings: spuriouser and spuriouser.
    Eisenkraft JB
    Anesthesiology; 1988 Jan; 68(1):171-2. PubMed ID: 3337381
    [No Abstract]   [Full Text] [Related]  

  • 12. Pulse oximeter changes with sentinel lymph node biopsy in breast cancer.
    El-Tamer M; Komenaka IK; Curry S; Troxel AB; Ditkoff BA; Schnabel FR
    Arch Surg; 2003 Nov; 138(11):1257-60. PubMed ID: 14609878
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of oesophageal pulse oximetry in patients undergoing cardiothoracic surgery.
    Kyriacou PA; Powell SL; Jones DP; Langford RM
    Anaesthesia; 2003 May; 58(5):422-7. PubMed ID: 12693996
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Characterization of the Rapid Drop in Pulse Oximetry Reading After Intraoperative Administration of Methylene Blue in Open Thoracoabdominal Aortic Repairs.
    Rong LQ; Mauer E; Mustapich TL; White RS; Di Franco A; Girardi LN; Gaudino M; Pryor KO
    Anesth Analg; 2019 Nov; 129(5):e142-e145. PubMed ID: 31397700
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Pulse oximetry in methaemoglobinaemia. Failure to detect low oxygen saturation.
    Rieder HU; Frei FJ; Zbinden AM; Thomson DA
    Anaesthesia; 1989 Apr; 44(4):326-7. PubMed ID: 2719205
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Intravenously administered indocyanine green may cause falsely high near-infrared cerebral oximetry readings.
    Yoo KY; Baek HY; Jeong S; Hallacoglu B; Lee J
    J Neurosurg Anesthesiol; 2015 Jan; 27(1):57-60. PubMed ID: 24922336
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect on oximetry of dyes used for sentinel lymph node biopsy.
    Piñero A; Illana J; García-Palenciano C; Cañizarese F; Canteras M; Cañadillas V; Durán E; Parilla P
    Arch Surg; 2004 Nov; 139(11):1204-7. PubMed ID: 15546820
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Misalignment of disposable pulse oximeter probes results in false saturation readings that influence anesthetic management.
    Guan Z; Baker K; Sandberg WS
    Anesth Analg; 2009 Nov; 109(5):1530-3. PubMed ID: 19843792
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An in vivo investigation of photoplethysmographic signals and preliminary pulse oximetry estimation from the bowel using a new fiberoptic sensor.
    Hickey M; Samuels N; Randive N; Langford RM; Kyriacou PA
    Anesth Analg; 2011 May; 112(5):1104-9. PubMed ID: 21346164
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Severe methemoglobinemia detected by pulse oximetry.
    Annabi EH; Barker SJ
    Anesth Analg; 2009 Mar; 108(3):898-9. PubMed ID: 19224799
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.