These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

230 related articles for article (PubMed ID: 22482616)

  • 21. Quality assurance of U.S.-guided external beam radiotherapy for prostate cancer: report of AAPM Task Group 154.
    Molloy JA; Chan G; Markovic A; McNeeley S; Pfeiffer D; Salter B; Tome WA;
    Med Phys; 2011 Feb; 38(2):857-71. PubMed ID: 21452723
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Investigation of cone-beam CT image quality trade-off for image-guided radiation therapy.
    Bian J; Sharp GC; Park YK; Ouyang J; Bortfeld T; El Fakhri G
    Phys Med Biol; 2016 May; 61(9):3317-46. PubMed ID: 27032676
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Quality Assurance Results for a Commercial Radiosurgery System: A Communication.
    Ruschin M; Lightstone A; Beachey D; Wronski M; Babic S; Yeboah C; Lee Y; Soliman H; Sahgal A
    Technol Cancer Res Treat; 2015 Oct; 14(5):601-5. PubMed ID: 24945371
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Intracranial stereotactic positioning systems: Report of the American Association of Physicists in Medicine Radiation Therapy Committee Task Group No. 68.
    Lightstone AW; Benedict SH; Bova FJ; Solberg TD; Stern RL
    Med Phys; 2005 Jul; 32(7Part1):2380-2398. PubMed ID: 28493584
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Enhancements to commissioning techniques and quality assurance of brachytherapy treatment planning systems that use model-based dose calculation algorithms.
    Rivard MJ; Beaulieu L; Mourtada F
    Med Phys; 2010 Jun; 37(6):2645-58. PubMed ID: 20632576
    [TBL] [Abstract][Full Text] [Related]  

  • 26. MO-D-211-01: Medical Physics Practice Guidelines - The Minimum Level of Medical Physics Support in Clinical Practice Settings.
    Chan M; Fontenot J; Halvorsen P
    Med Phys; 2012 Jun; 39(6Part21):3865. PubMed ID: 28518252
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Technical assessment of a cone-beam CT scanner for otolaryngology imaging: image quality, dose, and technique protocols.
    Xu J; Reh DD; Carey JP; Mahesh M; Siewerdsen JH
    Med Phys; 2012 Aug; 39(8):4932-42. PubMed ID: 22894419
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Investigation on the 3 D geometric accuracy and on the image quality (MTF, SNR and NPS) of volume tomography units (CT, CBCT and DVT)].
    Blendl C; Fiebich M; Voigt JM; Selbach M; Uphoff C
    Rofo; 2012 Jan; 184(1):24-31. PubMed ID: 22076796
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The European Society of Therapeutic Radiology and Oncology-European Institute of Radiotherapy (ESTRO-EIR) report on 3D CT-based in-room image guidance systems: a practical and technical review and guide.
    Korreman S; Rasch C; McNair H; Verellen D; Oelfke U; Maingon P; Mijnheer B; Khoo V
    Radiother Oncol; 2010 Feb; 94(2):129-44. PubMed ID: 20153908
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Intracranial stereotactic positioning systems: Report of the American Association of Physicists in Medicine Radiation Therapy Committee Task Group no. 68.
    Lightstone AW; Benedict SH; Bova FJ; Solberg TD; Stern RL;
    Med Phys; 2005 Jul; 32(7):2380-98. PubMed ID: 16121596
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Successful implementation of image-guided radiation therapy quality assurance in the Trans Tasman Radiation Oncology Group 08.01 PROFIT Study.
    Middleton M; Frantzis J; Healy B; Jones M; Murry R; Kron T; Plank A; Catton C; Martin J
    Int J Radiat Oncol Biol Phys; 2011 Dec; 81(5):1576-81. PubMed ID: 21074334
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Should image rotation be addressed during routine cone-beam CT quality assurance?
    Ayan AS; Lin H; Yeager C; Deville C; McDonough J; Zhu TC; Anderson N; Bar Ad V; Lu HM; Both S
    Phys Med Biol; 2013 Feb; 58(4):1059-73. PubMed ID: 23363650
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Proposal for a Simple and Efficient Monthly Quality Management Program Assessing the Consistency of Robotic Image-Guided Small Animal Radiation Systems.
    Brodin NP; Guha C; Tomé WA
    Health Phys; 2015 Nov; 109(3 Suppl 3):S190-9. PubMed ID: 26425981
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Recommendations for clinical electron beam dosimetry: supplement to the recommendations of Task Group 25.
    Gerbi BJ; Antolak JA; Deibel FC; Followill DS; Herman MG; Higgins PD; Huq MS; Mihailidis DN; Yorke ED; Hogstrom KR; Khan FM
    Med Phys; 2009 Jul; 36(7):3239-79. PubMed ID: 19673223
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Performance characteristics and quality assurance aspects of kilovoltage cone-beam CT on medical linear accelerator.
    Saw CB; Yang Y; Li F; Yue NJ; Ding C; Komanduri K; Huq S; Heron DE
    Med Dosim; 2007; 32(2):80-5. PubMed ID: 17472886
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Quality assurance for computed-tomography simulators and the computed-tomography-simulation process: report of the AAPM Radiation Therapy Committee Task Group No. 66.
    Mutic S; Palta JR; Butker EK; Das IJ; Huq MS; Loo LN; Salter BJ; McCollough CH; Van Dyk J;
    Med Phys; 2003 Oct; 30(10):2762-92. PubMed ID: 14596315
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Quality and Safety Considerations in Image Guided Radiation Therapy: An ASTRO Safety White Paper Update.
    Qi XS; Albuquerque K; Bailey S; Dawes S; Kashani R; Li H; Mak RH; Mundt AJ; Sio TT
    Pract Radiat Oncol; 2023; 13(2):97-111. PubMed ID: 36585312
    [TBL] [Abstract][Full Text] [Related]  

  • 38. In-room CT techniques for image-guided radiation therapy.
    Ma CM; Paskalev K
    Med Dosim; 2006; 31(1):30-9. PubMed ID: 16551527
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Systematic measurements of whole-body imaging dose distributions in image-guided radiation therapy.
    Halg RA; Besserer J; Schneider U
    Med Phys; 2012 Dec; 39(12):7650-61. PubMed ID: 23231313
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Faculty of Radiation Oncology Position Paper on the use of Image-Guided Radiation Therapy.
    Tiong A; Lao L; MacKean J; Goonetilleke M; Kron T
    J Med Imaging Radiat Oncol; 2016 Dec; 60(6):772-780. PubMed ID: 27122102
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.