22. Detection of brachytherapy seeds using 3-D transrectal ultrasound. Wen X; Salcudean ST; Lawrence PD IEEE Trans Biomed Eng; 2010 Oct; 57(10):2467-77. PubMed ID: 20595088 [TBL] [Abstract][Full Text] [Related]
23. The applicability of simultaneous TRUS-CT imaging for the evaluation of prostate seed implants. Steggerda M; Schneider C; van Herk M; Zijp L; Moonen L; van der Poel H Med Phys; 2005 Jul; 32(7):2262-70. PubMed ID: 16121581 [TBL] [Abstract][Full Text] [Related]
24. Precision grid and hand motion for accurate needle insertion in brachytherapy. McGill CS; Schwartz JA; Moore JZ; McLaughlin PW; Shih AJ Med Phys; 2011 Aug; 38(8):4749-59. PubMed ID: 21928648 [TBL] [Abstract][Full Text] [Related]
25. Three-Dimensional Needle Shape Estimation in TRUS-Guided Prostate Brachytherapy Using 2-D Ultrasound Images. Waine M; Rossa C; Sloboda R; Usmani N; Tavakoli M IEEE J Biomed Health Inform; 2016 Nov; 20(6):1621-1631. PubMed ID: 26372660 [TBL] [Abstract][Full Text] [Related]
26. A compact mechatronic system for 3D ultrasound guided prostate interventions. Bax J; Smith D; Bartha L; Montreuil J; Sherebrin S; Gardi L; Edirisinghe C; Fenster A Med Phys; 2011 Feb; 38(2):1055-69. PubMed ID: 21452743 [TBL] [Abstract][Full Text] [Related]
27. Design of an ultrasound-guided robotic brachytherapy needle-insertion system. Hungr N; Troccaz J; Zemiti N; Tripodi N Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():250-3. PubMed ID: 19964212 [TBL] [Abstract][Full Text] [Related]
28. Prostate brachytherapy with oblique needles to treat large glands and overcome pubic arch interference. Ryu B; Bax J; Edirisinge C; Lewis C; Chen J; D'Souza D; Fenster A; Wong E Int J Radiat Oncol Biol Phys; 2012 Aug; 83(5):1463-72. PubMed ID: 22270172 [TBL] [Abstract][Full Text] [Related]
29. An ultrasound image navigation robotic prostate brachytherapy system based on US to MRI deformable image registration method. Zhang S; Jiang S; Yang Z; Liu R; Yang Y; Liang H Hell J Nucl Med; 2016; 19(3):223-230. PubMed ID: 27824961 [TBL] [Abstract][Full Text] [Related]
30. A novel method for accurate needle-tip identification in trans-rectal ultrasound-based high-dose-rate prostate brachytherapy. Zheng D; Todor DA Brachytherapy; 2011; 10(6):466-73. PubMed ID: 21549646 [TBL] [Abstract][Full Text] [Related]
31. Oblique needle segmentation and tracking for 3D TRUS guided prostate brachytherapy. Wei Z; Gardi L; Downey DB; Fenster A Med Phys; 2005 Sep; 32(9):2928-41. PubMed ID: 16266107 [TBL] [Abstract][Full Text] [Related]
32. Technical Note: The design, construction, and evaluation of a liquid-based single phantom solution for TG128 brachytherapy ultrasound QA. Leong B; Ostyn M; Oh S; Kim S Med Phys; 2019 Feb; 46(2):1024-1029. PubMed ID: 30472737 [TBL] [Abstract][Full Text] [Related]
33. Brachytherapy needle deflection evaluation and correction. Wan G; Wei Z; Gardi L; Downey DB; Fenster A Med Phys; 2005 Apr; 32(4):902-9. PubMed ID: 15895572 [TBL] [Abstract][Full Text] [Related]
34. Observations on rotating needle insertions using a brachytherapy robot. Meltsner MA; Ferrier NJ; Thomadsen BR Phys Med Biol; 2007 Oct; 52(19):6027-37. PubMed ID: 17881817 [TBL] [Abstract][Full Text] [Related]
35. Measurement of prostate rotation during insertion of needles for brachytherapy. Lagerburg V; Moerland MA; Lagendijk JJ; Battermann JJ Radiother Oncol; 2005 Dec; 77(3):318-23. PubMed ID: 16289399 [TBL] [Abstract][Full Text] [Related]
36. A system for MRI-guided transperineal delivery of needles to the prostate for focal therapy. Cepek J; Chronik BA; Lindner U; Trachtenberg J; Davidson SR; Bax J; Fenster A Med Phys; 2013 Jan; 40(1):012304. PubMed ID: 23298109 [TBL] [Abstract][Full Text] [Related]
37. Improving ultrasound-based brachytherapy needle conspicuity by applying an echogenic coating. Brost EE; Stish BJ; Lee CU; Urban MW; Deufel CL Med Phys; 2023 Mar; 50(3):1418-1427. PubMed ID: 36511174 [TBL] [Abstract][Full Text] [Related]
38. Single shot MR tagging to quantify local tissue deformation during MRI-guided needle interventions: a feasibility study. van den Bosch MR; de Leeuw H; Zwanenburg JJ; Lagendijk JJ; Moerland MA Med Phys; 2011 Oct; 38(10):5321-9. PubMed ID: 21992350 [TBL] [Abstract][Full Text] [Related]
39. A needle guidance system for biopsy and therapy using two-dimensional ultrasound. Bluvol N; Sheikh A; Kornecki A; Fernandez Ddel R; Downey D; Fenster A Med Phys; 2008 Feb; 35(2):617-28. PubMed ID: 18383683 [TBL] [Abstract][Full Text] [Related]
40. Use and uncertainties of mutual information for computed tomography/ magnetic resonance (CT/MR) registration post permanent implant of the prostate. Roberson PL; McLaughlin PW; Narayana V; Troyer S; Hixson GV; Kessler ML Med Phys; 2005 Feb; 32(2):473-82. PubMed ID: 15789594 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]