These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

220 related articles for article (PubMed ID: 22482624)

  • 21. Needle-tissue interaction modeling using ultrasound-based motion estimation: phantom study.
    Dehghan E; Wen X; Zahiri-Azar R; Marchal M; Salcudean SE
    Comput Aided Surg; 2008 Sep; 13(5):265-80. PubMed ID: 18821345
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Detection of brachytherapy seeds using 3-D transrectal ultrasound.
    Wen X; Salcudean ST; Lawrence PD
    IEEE Trans Biomed Eng; 2010 Oct; 57(10):2467-77. PubMed ID: 20595088
    [TBL] [Abstract][Full Text] [Related]  

  • 23. The applicability of simultaneous TRUS-CT imaging for the evaluation of prostate seed implants.
    Steggerda M; Schneider C; van Herk M; Zijp L; Moonen L; van der Poel H
    Med Phys; 2005 Jul; 32(7):2262-70. PubMed ID: 16121581
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Precision grid and hand motion for accurate needle insertion in brachytherapy.
    McGill CS; Schwartz JA; Moore JZ; McLaughlin PW; Shih AJ
    Med Phys; 2011 Aug; 38(8):4749-59. PubMed ID: 21928648
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Three-Dimensional Needle Shape Estimation in TRUS-Guided Prostate Brachytherapy Using 2-D Ultrasound Images.
    Waine M; Rossa C; Sloboda R; Usmani N; Tavakoli M
    IEEE J Biomed Health Inform; 2016 Nov; 20(6):1621-1631. PubMed ID: 26372660
    [TBL] [Abstract][Full Text] [Related]  

  • 26. A compact mechatronic system for 3D ultrasound guided prostate interventions.
    Bax J; Smith D; Bartha L; Montreuil J; Sherebrin S; Gardi L; Edirisinghe C; Fenster A
    Med Phys; 2011 Feb; 38(2):1055-69. PubMed ID: 21452743
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Design of an ultrasound-guided robotic brachytherapy needle-insertion system.
    Hungr N; Troccaz J; Zemiti N; Tripodi N
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():250-3. PubMed ID: 19964212
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Prostate brachytherapy with oblique needles to treat large glands and overcome pubic arch interference.
    Ryu B; Bax J; Edirisinge C; Lewis C; Chen J; D'Souza D; Fenster A; Wong E
    Int J Radiat Oncol Biol Phys; 2012 Aug; 83(5):1463-72. PubMed ID: 22270172
    [TBL] [Abstract][Full Text] [Related]  

  • 29. An ultrasound image navigation robotic prostate brachytherapy system based on US to MRI deformable image registration method.
    Zhang S; Jiang S; Yang Z; Liu R; Yang Y; Liang H
    Hell J Nucl Med; 2016; 19(3):223-230. PubMed ID: 27824961
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A novel method for accurate needle-tip identification in trans-rectal ultrasound-based high-dose-rate prostate brachytherapy.
    Zheng D; Todor DA
    Brachytherapy; 2011; 10(6):466-73. PubMed ID: 21549646
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Oblique needle segmentation and tracking for 3D TRUS guided prostate brachytherapy.
    Wei Z; Gardi L; Downey DB; Fenster A
    Med Phys; 2005 Sep; 32(9):2928-41. PubMed ID: 16266107
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Technical Note: The design, construction, and evaluation of a liquid-based single phantom solution for TG128 brachytherapy ultrasound QA.
    Leong B; Ostyn M; Oh S; Kim S
    Med Phys; 2019 Feb; 46(2):1024-1029. PubMed ID: 30472737
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Brachytherapy needle deflection evaluation and correction.
    Wan G; Wei Z; Gardi L; Downey DB; Fenster A
    Med Phys; 2005 Apr; 32(4):902-9. PubMed ID: 15895572
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Observations on rotating needle insertions using a brachytherapy robot.
    Meltsner MA; Ferrier NJ; Thomadsen BR
    Phys Med Biol; 2007 Oct; 52(19):6027-37. PubMed ID: 17881817
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Measurement of prostate rotation during insertion of needles for brachytherapy.
    Lagerburg V; Moerland MA; Lagendijk JJ; Battermann JJ
    Radiother Oncol; 2005 Dec; 77(3):318-23. PubMed ID: 16289399
    [TBL] [Abstract][Full Text] [Related]  

  • 36. A system for MRI-guided transperineal delivery of needles to the prostate for focal therapy.
    Cepek J; Chronik BA; Lindner U; Trachtenberg J; Davidson SR; Bax J; Fenster A
    Med Phys; 2013 Jan; 40(1):012304. PubMed ID: 23298109
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Improving ultrasound-based brachytherapy needle conspicuity by applying an echogenic coating.
    Brost EE; Stish BJ; Lee CU; Urban MW; Deufel CL
    Med Phys; 2023 Mar; 50(3):1418-1427. PubMed ID: 36511174
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Single shot MR tagging to quantify local tissue deformation during MRI-guided needle interventions: a feasibility study.
    van den Bosch MR; de Leeuw H; Zwanenburg JJ; Lagendijk JJ; Moerland MA
    Med Phys; 2011 Oct; 38(10):5321-9. PubMed ID: 21992350
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A needle guidance system for biopsy and therapy using two-dimensional ultrasound.
    Bluvol N; Sheikh A; Kornecki A; Fernandez Ddel R; Downey D; Fenster A
    Med Phys; 2008 Feb; 35(2):617-28. PubMed ID: 18383683
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Use and uncertainties of mutual information for computed tomography/ magnetic resonance (CT/MR) registration post permanent implant of the prostate.
    Roberson PL; McLaughlin PW; Narayana V; Troyer S; Hixson GV; Kessler ML
    Med Phys; 2005 Feb; 32(2):473-82. PubMed ID: 15789594
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.