BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

221 related articles for article (PubMed ID: 22489991)

  • 1. Transillumination-assisted orotracheal intubation: a comparison of the Bonfils fibrescope and the lightwand (Trachlight).
    Sui JH; Mao P; Liu JH; Tong SY; Wei LX; Yang D; Deng XM
    Acta Anaesthesiol Scand; 2012 May; 56(5):565-70. PubMed ID: 22489991
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Awake intubation with the Bonfils fibrescope in patients with difficult airway.
    Corbanese U; Possamai C
    Eur J Anaesthesiol; 2009 Oct; 26(10):837-41. PubMed ID: 19474737
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A comparison of the intubating laryngeal mask airway and the Bonfils intubation fibrescope in patients with predicted difficult airways.
    Bein B; Worthmann F; Scholz J; Brinkmann F; Tonner PH; Steinfath M; Dörges V
    Anaesthesia; 2004 Jul; 59(7):668-74. PubMed ID: 15200542
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of the Bonfils intubating fibrescope for predicted difficult intubation in awake patients with ear, nose and throat cancer.
    Mazères JE; Lefranc A; Cropet C; Steghens A; Bachmann P; Pérol O; Rosay H
    Eur J Anaesthesiol; 2011 Sep; 28(9):646-50. PubMed ID: 21743336
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effective nasotracheal intubation using a modified transillumination technique.
    Favaro R; Tordiglione P; Di Lascio F; Colagiovanni D; Esposito G; Quaranta S; Gasparetto A
    Can J Anaesth; 2002 Jan; 49(1):91-5. PubMed ID: 11782336
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A comparison of the transillumination-assisted technique versus midline approach technique in novices: a prospective randomized controlled trial about the Bonfils intubation fiberscope.
    Wang J; Yuan L; Fu G; Tang W; Yu G; Guo F; Song J
    BMC Anesthesiol; 2017 Feb; 17(1):31. PubMed ID: 28222696
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Is Trachlight really better than the Bonfils fibrescope?
    Falcetta S; Pecora L; Orsetti G; Gentili P; Rossi A; Gabbanelli V; Adrario E; Donati A; Pelaia P
    Acta Anaesthesiol Scand; 2013 Apr; 57(4):529. PubMed ID: 23075465
    [No Abstract]   [Full Text] [Related]  

  • 8. A comparison between the Bonfils Intubation Fiberscope and McCoy laryngoscope for tracheal intubation in patients with a simulated difficult airway.
    Abdullah HR; Li-Ming T; Marriott A; Wong TG
    Anesth Analg; 2013 Nov; 117(5):1217-20. PubMed ID: 24029854
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reply to - is Trachlight really better than the Bonfils fibrescope?
    Sui JH; Mao P; Deng XM
    Acta Anaesthesiol Scand; 2013 Apr; 57(4):529-30. PubMed ID: 23379794
    [No Abstract]   [Full Text] [Related]  

  • 10. Heart rate/blood pressure response and airway morbidity following tracheal intubation with direct laryngoscopy, GlideScope and Trachlight: a randomized control trial.
    Siddiqui N; Katznelson R; Friedman Z
    Eur J Anaesthesiol; 2009 Sep; 26(9):740-5. PubMed ID: 19417675
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Movement of the upper cervical spine during laryngoscopy: a comparison of the Bonfils intubation fibrescope and the Macintosh laryngoscope.
    Rudolph C; Schneider JP; Wallenborn J; Schaffranietz L
    Anaesthesia; 2005 Jul; 60(7):668-72. PubMed ID: 15960717
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Reduced hemodynamic responses to tracheal intubation by the Bonfils retromolar fiberscope: a randomized controlled study.
    Boker A; Almarakbi WA; Arab AA; Almazrooa AA
    Middle East J Anaesthesiol; 2011 Oct; 21(3):385-90. PubMed ID: 22428493
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Transillumination technique in difficult intubations in heart surgery].
    Gille A; Komar K; Schmidt E; Alexander T
    Anasthesiol Intensivmed Notfallmed Schmerzther; 2002 Oct; 37(10):604-8. PubMed ID: 12369013
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Tracheal intubation using the Bonfils intubation fibrescope after failed direct laryngoscopy.
    Bein B; Yan M; Tonner PH; Scholz J; Steinfath M; Dörges V
    Anaesthesia; 2004 Dec; 59(12):1207-9. PubMed ID: 15549980
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of the Bonfils and Levitan optical stylets for tracheal intubation: a clinical study.
    Webb A; Kolawole H; Leong S; Loughnan TE; Crofts T; Bowden C
    Anaesth Intensive Care; 2011 Nov; 39(6):1093-7. PubMed ID: 22165364
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Awake tracheal intubation in a patient with a supraglottic mass with the Bonfils fibrescope after failed attempts with a flexible fibrescope.
    Liew G; Leong XF; Wong T
    Singapore Med J; 2015 Aug; 56(8):e139-41. PubMed ID: 25902720
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A clinical evaluation of the Bonfils Intubation Fibrescope.
    Halligan M; Charters P
    Anaesthesia; 2003 Nov; 58(11):1087-91. PubMed ID: 14616594
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Bonfils intubation fibrescope: use in simulation-based intubation training for medical students in comparison to MacIntosh laryngoscope.
    Limbach T; Ott T; Griesinger J; Jahn-Eimermacher A; Piepho T
    BMC Res Notes; 2016 Feb; 9():127. PubMed ID: 26920895
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effectiveness of lightwand (Trachlight) intubation by 1st year anesthesia residents.
    Amornyotin S; Sanansilp V; Amorntien V; Tirawat P
    J Med Assoc Thai; 2002 Sep; 85 Suppl 3():S963-8. PubMed ID: 12452236
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Light-guided intubation using Trachlight].
    Falsini S; Cimminiello D; Gandini E; Melani AM; Manfredini F; Signorini P; Novelli GP
    Minerva Anestesiol; 1996 Nov; 62(11):377-83. PubMed ID: 9102587
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.