BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

287 related articles for article (PubMed ID: 22502570)

  • 1. Blood oxygen flux estimation with a combined photoacoustic and high-frequency ultrasound microscopy system: a phantom study.
    Jiang Y; Forbrich A; Harrison T; Zemp RJ
    J Biomed Opt; 2012 Mar; 17(3):036012. PubMed ID: 22502570
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Photoacoustic and high-frequency power Doppler ultrasound biomicroscopy: a comparative study.
    Jiang Y; Harrison T; Ranasinghesagara J; Zemp RJ
    J Biomed Opt; 2010; 15(5):056008. PubMed ID: 21054102
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Photoacoustic computed microscopy.
    Yao L; Xi L; Jiang H
    Sci Rep; 2014 May; 4():4960. PubMed ID: 24828539
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Molecular specificity in photoacoustic microscopy by time-resolved transient absorption.
    Shelton RL; Mattison SP; Applegate BE
    Opt Lett; 2014 Jun; 39(11):3102-5. PubMed ID: 24875987
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Estimation of cerebral metabolic rate of oxygen consumption using combined multiwavelength photoacoustic microscopy and Doppler microultrasound.
    Jiang Y; Zemp R
    J Biomed Opt; 2018 Jan; 23(1):1-7. PubMed ID: 29349952
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Ultrasound-aided Multi-parametric Photoacoustic Microscopy of the Mouse Brain.
    Ning B; Sun N; Cao R; Chen R; Kirk Shung K; Hossack JA; Lee JM; Zhou Q; Hu S
    Sci Rep; 2015 Dec; 5():18775. PubMed ID: 26688368
    [TBL] [Abstract][Full Text] [Related]  

  • 7. 2  MHz multi-wavelength pulsed laser for functional photoacoustic microscopy.
    Liang Y; Jin L; Guan BO; Wang L
    Opt Lett; 2017 Apr; 42(7):1452-1455. PubMed ID: 28362790
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In vivo optically encoded photoacoustic flowgraphy.
    Zhang R; Wang L; Yao J; Yeh CH; Wang LV
    Opt Lett; 2014 Jul; 39(13):3814-7. PubMed ID: 24978744
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reflection-mode multifocal optical-resolution photoacoustic microscopy.
    Li G; Maslov KI; Wang LV
    J Biomed Opt; 2013 Mar; 18(3):030501. PubMed ID: 23446704
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pulsed photoacoustic flow imaging with a handheld system.
    van den Berg PJ; Daoudi K; Steenbergen W
    J Biomed Opt; 2016 Feb; 21(2):26004. PubMed ID: 26857470
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Spectrally encoded photoacoustic microscopy using a digital mirror device.
    Wang Y; Maslov K; Wang LV
    J Biomed Opt; 2012 Jun; 17(6):066020. PubMed ID: 22734776
    [TBL] [Abstract][Full Text] [Related]  

  • 12. In vivo three-dimensional photoacoustic imaging based on a clinical matrix array ultrasound probe.
    Wang Y; Erpelding TN; Jankovic L; Guo Z; Robert JL; David G; Wang LV
    J Biomed Opt; 2012 Jun; 17(6):061208. PubMed ID: 22734738
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Photoacoustic spectrum analysis for microstructure characterization in biological tissue: analytical model.
    Xu G; Fowlkes JB; Tao C; Liu X; Wang X
    Ultrasound Med Biol; 2015 May; 41(5):1473-80. PubMed ID: 25748521
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Processing methods for photoacoustic Doppler flowmetry with a clinical ultrasound scanner.
    Bücking TM; van den Berg PJ; Balabani S; Steenbergen W; Beard PC; Brunker J
    J Biomed Opt; 2018 Feb; 23(2):1-8. PubMed ID: 29488363
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Quantitative spatially resolved measurement of tissue chromophore concentrations using photoacoustic spectroscopy: application to the measurement of blood oxygenation and haemoglobin concentration.
    Laufer J; Delpy D; Elwell C; Beard P
    Phys Med Biol; 2007 Jan; 52(1):141-68. PubMed ID: 17183133
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Quantitative blood oxygen saturation imaging using combined photoacoustics and acousto-optics.
    Hussain A; Petersen W; Staley J; Hondebrink E; Steenbergen W
    Opt Lett; 2016 Apr; 41(8):1720-3. PubMed ID: 27082328
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Transparent High-Frequency Ultrasonic Transducer for Photoacoustic Microscopy Application.
    Chen R; He Y; Shi J; Yung C; Hwang J; Wang LV; Zhou Q
    IEEE Trans Ultrason Ferroelectr Freq Control; 2020 Sep; 67(9):1848-1853. PubMed ID: 32286968
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Opto-acoustic imaging of relative blood oxygen saturation and total hemoglobin for breast cancer diagnosis.
    Zalev J; Richards LM; Clingman BA; Harris J; Cantu E; Menezes GLG; Avila C; Bertrand A; Saenz X; Miller S; Oraevsky AA; Kolios MC
    J Biomed Opt; 2019 Dec; 24(12):1-16. PubMed ID: 31849204
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Acoustic resolution photoacoustic Doppler flowmetry for assessment of patient rectal cancer blood perfusion.
    Kou S; Leng X; Luo H; Nie H; Zhu Q
    J Biomed Opt; 2024 Jan; 29(Suppl 1):S11517. PubMed ID: 38223679
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Stomach wall structure and vessels imaging by acoustic resolution photoacoustic microscopy.
    Wang C; Lu YF; Cai CM; Xiang HZ; Zheng G
    World J Gastroenterol; 2018 Aug; 24(31):3531-3537. PubMed ID: 30131659
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.