These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

318 related articles for article (PubMed ID: 22503584)

  • 1. Usefulness of continuous electrocardiographic monitoring for atrial fibrillation.
    Camm AJ; Corbucci G; Padeletti L
    Am J Cardiol; 2012 Jul; 110(2):270-6. PubMed ID: 22503584
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Detection of previously undiagnosed atrial fibrillation in patients with stroke risk factors and usefulness of continuous monitoring in primary stroke prevention.
    Ziegler PD; Glotzer TV; Daoud EG; Singer DE; Ezekowitz MD; Hoyt RH; Koehler JL; Coles J; Wyse DG
    Am J Cardiol; 2012 Nov; 110(9):1309-14. PubMed ID: 22819433
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Subclinical atrial fibrillation and stroke: insights from continuous monitoring by implanted cardiac electronic devices.
    Lau CP; Siu CW; Yiu KH; Lee KL; Chan YH; Tse HF
    Europace; 2015 Oct; 17 Suppl 2():ii40-6. PubMed ID: 26842114
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Diagnosis of paroxysmal atrial fibrillation in patients with implanted pacemakers: relationship to symptoms and other variables.
    Quirino G; Giammaria M; Corbucci G; Pistelli P; Turri E; Mazza A; Perucca A; Checchinato C; Dalmasso M; Barold SS
    Pacing Clin Electrophysiol; 2009 Jan; 32(1):91-8. PubMed ID: 19140918
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Disease management: atrial fibrillation and home monitoring.
    Ricci RP
    Europace; 2013 Jun; 15 Suppl 1():i35-i39. PubMed ID: 23737228
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cryptogenic stroke: Is silent atrial fibrillation the culprit?
    Glotzer TV; Ziegler PD
    Heart Rhythm; 2015 Jan; 12(1):234-41. PubMed ID: 25285649
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Performance of a new leadless implantable cardiac monitor in detecting and quantifying atrial fibrillation: Results of the XPECT trial.
    Hindricks G; Pokushalov E; Urban L; Taborsky M; Kuck KH; Lebedev D; Rieger G; Pürerfellner H;
    Circ Arrhythm Electrophysiol; 2010 Apr; 3(2):141-7. PubMed ID: 20160169
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Silent atrial fibrillation as a stroke risk factor and anticoagulation indication.
    Glotzer TV; Ziegler PD
    Can J Cardiol; 2013 Jul; 29(7 Suppl):S14-23. PubMed ID: 23790594
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ambulatory external electrocardiographic monitoring: focus on atrial fibrillation.
    Mittal S; Movsowitz C; Steinberg JS
    J Am Coll Cardiol; 2011 Oct; 58(17):1741-9. PubMed ID: 21996384
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ablation of paroxysmal atrial fibrillation during coronary artery bypass grafting: 12 months' follow-up through implantable loop recorder.
    Pokushalov E; Romanov A; Cherniavsky A; Corbucci G; Pak I; Kareva Y; Karaskov A
    Eur J Cardiothorac Surg; 2011 Aug; 40(2):405-11. PubMed ID: 21601472
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Silent ischaemic brain lesions related to atrial high rate episodes in patients with cardiac implantable electronic devices.
    Benezet-Mazuecos J; Rubio JM; Cortés M; Iglesias JA; Calle S; de la Vieja JJ; Quiñones MA; Sanchez-Borque P; de la Cruz E; Espejo A; Farré J
    Europace; 2015 Mar; 17(3):364-9. PubMed ID: 25336664
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Monitoring of atrial fibrillation burden after surgical ablation: relevancy of end-point criteria after radiofrequency ablation treatment of patients with lone atrial fibrillation.
    Beukema R; Beukema WP; Sie HT; Misier AR; Delnoy PP; Elvan A
    Interact Cardiovasc Thorac Surg; 2009 Dec; 9(6):956-9. PubMed ID: 19762419
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Assessment of atrial fibrillation ablation outcome: from symptoms to continuous monitoring with an implantable loop recorder].
    Rordorf R; Vicentini A; Landolina M
    G Ital Cardiol (Rome); 2008 Oct; 9(10 Suppl 1):16S-21S. PubMed ID: 19195301
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Feasibility of extended ambulatory electrocardiogram monitoring to identify silent atrial fibrillation in high-risk patients: the Screening Study for Undiagnosed Atrial Fibrillation (STUDY-AF).
    Turakhia MP; Ullal AJ; Hoang DD; Than CT; Miller JD; Friday KJ; Perez MV; Freeman JV; Wang PJ; Heidenreich PA
    Clin Cardiol; 2015 May; 38(5):285-92. PubMed ID: 25873476
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Multicenter randomized study of anticoagulation guided by remote rhythm monitoring in patients with implantable cardioverter-defibrillator and CRT-D devices: Rationale, design, and clinical characteristics of the initially enrolled cohort The IMPACT study.
    Ip J; Waldo AL; Lip GY; Rothwell PM; Martin DT; Bersohn MM; Choucair WK; Akar JG; Wathen MS; Rohani P; Halperin JL;
    Am Heart J; 2009 Sep; 158(3):364-370.e1. PubMed ID: 19699858
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Holter monitoring in the diagnosis of stroke mechanism.
    Shafqat S; Kelly PJ; Furie KL
    Intern Med J; 2004 Jun; 34(6):305-9. PubMed ID: 15228390
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Improved screening for silent atrial fibrillation after ischaemic stroke.
    Doliwa Sobocinski P; Anggårdh Rooth E; Frykman Kull V; von Arbin M; Wallén H; Rosenqvist M
    Europace; 2012 Aug; 14(8):1112-6. PubMed ID: 22308086
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Role of cardiac electronic implantable device in the stratification and management of embolic risk of silent atrial fibrillation: are all atrial fibrillations created equal?
    Di Cori A; Lilli A; Zucchelli G; Zaca V
    Expert Rev Cardiovasc Ther; 2018 Mar; 16(3):175-181. PubMed ID: 29431527
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Atrial defibrillators or implantable atrioverters. Initial results].
    Lévy S; Taramasco V; Corbelli JL; Mistretta R; Dolla E; Ricard P
    Arch Mal Coeur Vaiss; 1998 Jul; 91(7):887-91. PubMed ID: 9749182
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Cost-effectiveness of early detection of atrial fibrillation via remote control of implanted devices.
    Lorenzoni G; Folino F; Soriani N; Iliceto S; Gregori D
    J Eval Clin Pract; 2014 Oct; 20(5):570-7. PubMed ID: 24766368
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.