These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

196 related articles for article (PubMed ID: 22508580)

  • 1. The optimization of wireless power transmission: design and realization.
    Jia Z; Yan G; Liu H; Wang Z; Jiang P; Shi Y
    Int J Med Robot; 2012 Sep; 8(3):337-47. PubMed ID: 22508580
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Efficiency optimization of wireless power transmission systems for active capsule endoscopes.
    Zhiwei J; Guozheng Y; Jiangpingping ; Zhiwu W; Hua L
    Physiol Meas; 2011 Oct; 32(10):1561-73. PubMed ID: 21873764
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [A wireless power transmission system for capsule endoscope].
    Xin W; Yan G; Wang W
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2010 Jun; 27(3):490-4. PubMed ID: 20649004
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Study of a wireless power transmission system for an active capsule endoscope.
    Xin W; Yan G; Wang W
    Int J Med Robot; 2010 Mar; 6(1):113-22. PubMed ID: 20112281
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Research on wireless power transmission for gastrointestinal microsystems based on inductive coupling].
    Ma G; Yan G
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Feb; 25(1):61-4, 87. PubMed ID: 18435258
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Portable wireless power transmission system for video capsule endoscopy.
    Zhiwei J; Guozheng Y; Bingquan Z
    J Med Eng Technol; 2014 Oct; 38(7):351-8. PubMed ID: 25082182
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An active endoscopic robot based on wireless power transmission and electromagnetic localization.
    Li H; Yan G; Ma G
    Int J Med Robot; 2008 Dec; 4(4):355-67. PubMed ID: 18956414
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A wireless power transmission system for an active capsule endoscope for colon inspection.
    Jia Z; Yan G; Shi Y; Zhu B
    J Med Eng Technol; 2012 Jul; 36(5):235-41. PubMed ID: 22506834
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A portable wireless power transmission system for video capsule endoscopes.
    Shi Y; Yan G; Zhu B; Liu G
    Biomed Mater Eng; 2015; 26 Suppl 1():S1721-30. PubMed ID: 26405939
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An inductive power link for a wireless endoscope.
    Lenaerts B; Puers R
    Biosens Bioelectron; 2007 Feb; 22(7):1390-5. PubMed ID: 16904885
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Energy transmission transformer for a wireless capsule endoscope: analysis of specific absorption rate and current density in biological tissue.
    Shiba K; Nagato T; Tsuji T; Koshiji K
    IEEE Trans Biomed Eng; 2008 Jul; 55(7):1864-71. PubMed ID: 18595805
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Micro-intestinal robot with wireless power transmission: design, analysis and experiment.
    Shi Y; Yan G; Chen W; Zhu B
    Comput Biol Med; 2015 Nov; 66():343-51. PubMed ID: 26278992
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Wireless technologies for robotic endoscope in gastrointestinal tract.
    Gao P; Yan G; Wang Z; Liu H
    J Med Eng Technol; 2012 Jul; 36(5):242-50. PubMed ID: 22594607
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Design and fabrication of a magnetic propulsion system for self-propelled capsule endoscope.
    Gao M; Hu C; Chen Z; Zhang H; Liu S
    IEEE Trans Biomed Eng; 2010 Dec; 57(12):2891-902. PubMed ID: 20542758
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Initial experimental evaluation of wireless capsule endoscopes in the bladder: implications for capsule cystoscopy.
    Gettman MT; Swain P
    Eur Urol; 2009 May; 55(5):1207-12. PubMed ID: 19201077
    [TBL] [Abstract][Full Text] [Related]  

  • 16. First clinical trial of the "MiRo" capsule endoscope by using a novel transmission technology: electric-field propagation.
    Bang S; Park JY; Jeong S; Kim YH; Shim HB; Kim TS; Lee DH; Song SY
    Gastrointest Endosc; 2009 Feb; 69(2):253-9. PubMed ID: 18640676
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Remote magnetic manipulation of a wireless capsule endoscope in the esophagus and stomach of humans (with videos).
    Swain P; Toor A; Volke F; Keller J; Gerber J; Rabinovitz E; Rothstein RI
    Gastrointest Endosc; 2010 Jun; 71(7):1290-3. PubMed ID: 20417507
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Three-dimensional power receiver for in vivo robotic capsules.
    Ryu M; Kim JD; Chin HU; Kim J; Song SY
    Med Biol Eng Comput; 2007 Oct; 45(10):997-1002. PubMed ID: 17684783
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A stable wireless energy transmission system for gastrointestinal microsystems.
    Xin WH; Yan GZ; Wang WX
    J Med Eng Technol; 2010 Jan; 34(1):64-70. PubMed ID: 19929570
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Design and analysis of a wireless power transfer system for capsule robot using an optimised planar square spiral transmitting coil pair.
    Zhuang H; Wang W; Zhao K; Fei Q; Yan G
    Int J Med Robot; 2022 Aug; 18(4):e2399. PubMed ID: 35397196
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.