BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

412 related articles for article (PubMed ID: 22511557)

  • 1. Long-term effects on vascular healing of bare metal stents delivered via paclitaxel-coated balloons in the porcine model of restenosis.
    Cremers B; Milewski K; Clever YP; Aboodi MS; Biedermann M; Thim T; Kelsch B; Kaluza GL; Scheller B; Granada JF
    Catheter Cardiovasc Interv; 2012 Oct; 80(4):603-10. PubMed ID: 22511557
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biological effect on drug distribution and vascular healing via paclitaxel-coated balloon technology in drug eluting stent restenosis swine model.
    Li Y; Tellez A; Rousselle SD; Dillon KN; Garza JA; Barry C; Granada JF
    Catheter Cardiovasc Interv; 2016 Jul; 88(1):89-98. PubMed ID: 26613810
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Cutting balloon combined with paclitaxel-eluting balloon for treatment of in-stent restenosis.
    Kong J; Hou J; Ma L; Xing L; Jia H; Liu H; Zhang S; Yu B; Jang IK
    Arch Cardiovasc Dis; 2013 Feb; 106(2):79-85. PubMed ID: 23527911
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Influence of a paclitaxel coated balloon in combination with a bare metal stent on restenosis and endothelial function: comparison with a drug eluting stent and a bare metal stent.
    Clever YP; Cremers B; Speck U; Dietz U; Böhm M; Scheller B
    Catheter Cardiovasc Interv; 2014 Aug; 84(2):323-31. PubMed ID: 23996969
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Stent coverage and neointimal proliferation in bare metal stents postdilated with a Paclitaxel-eluting balloon versus everolimus-eluting stents: prospective randomized study using optical coherence tomography at 6-month follow-up.
    Poerner TC; Otto S; Gassdorf J; Nitsche K; Janiak F; Scheller B; Goebel B; Jung C; Figulla HR
    Circ Cardiovasc Interv; 2014 Dec; 7(6):760-7. PubMed ID: 25371536
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optical coherence tomography (OCT) in PCI for in-stent restenosis (ISR): rationale and design of the SEDUCE (Safety and Efficacy of a Drug elUting balloon in Coronary artery rEstenosis) study.
    Adriaenssens T; Dens J; Ughi G; Coosemans M; Onsea K; Dubois C; Sinnaeve P; Vrolix M; Desmet W
    EuroIntervention; 2011 May; 7 Suppl K():K100-5. PubMed ID: 22027717
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Impact of post-intervention minimal stent area on 9-month follow-up patency of paclitaxel-eluting stents: an integrated intravascular ultrasound analysis from the TAXUS IV, V, and VI and TAXUS ATLAS Workhorse, Long Lesion, and Direct Stent Trials.
    Doi H; Maehara A; Mintz GS; Yu A; Wang H; Mandinov L; Popma JJ; Ellis SG; Grube E; Dawkins KD; Weissman NJ; Turco MA; Ormiston JA; Stone GW
    JACC Cardiovasc Interv; 2009 Dec; 2(12):1269-75. PubMed ID: 20129555
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Description of Pantera Lux paclitaxel-releasing balloon and preliminary quantitative coronary angiography (QCA) results at six months in patients with coronary in-stent restenosis.
    Hehrlein C; Richardt G; Wiemer M; Schneider H; Naber C; Hoffmann E; Dietz U
    EuroIntervention; 2011 May; 7 Suppl K():K119-24. PubMed ID: 22027721
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Stent healing response following delivery of paclitaxel via durable polymeric matrix versus iopromide-based balloon coating in the familial hypercholesterolaemic swine model of coronary injury.
    Buszman PP; Tellez A; Afari M; Cheng Y; Conditt GB; McGregor JC; Milewski K; Stenoien M; Kaluza GL; Granada JF
    EuroIntervention; 2013 Aug; 9(4):510-6. PubMed ID: 23965356
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Paclitaxel-coated balloon with bare-metal stenting in patients with chronic total occlusions in native coronary arteries.
    Wöhrle J; Werner GS
    Catheter Cardiovasc Interv; 2013 Apr; 81(5):793-9. PubMed ID: 22511572
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Long-Term Outcomes After Treatment With a Paclitaxel-Coated Balloon Versus Balloon Angioplasty: Insights From the PEPCAD-DES Study (Treatment of Drug-eluting Stent [DES] In-Stent Restenosis With SeQuent Please Paclitaxel-Coated Percutaneous Transluminal Coronary Angioplasty [PTCA] Catheter).
    Rittger H; Waliszewski M; Brachmann J; Hohenforst-Schmidt W; Ohlow M; Brugger A; Thiele H; Birkemeyer R; Kurowski V; Schlundt C; Zimmermann S; Lonke S; von Cranach M; Markovic S; Daniel WG; Achenbach S; Wöhrle J
    JACC Cardiovasc Interv; 2015 Nov; 8(13):1695-700. PubMed ID: 26476609
    [TBL] [Abstract][Full Text] [Related]  

  • 12. INtimal hyPerplasia evAluated by oCT in de novo COROnary lesions treated by drug-eluting balloon and bare-metal stent (IN-PACT CORO): study protocol for a randomized controlled trial.
    Burzotta F; Brancati MF; Trani C; Porto I; Tommasino A; De Maria G; Niccoli G; Leone AM; Coluccia V; Schiavoni G; Crea F
    Trials; 2012 May; 13():55. PubMed ID: 22559260
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In vivo evaluation of a biolimus eluting nickel titanium self expanding stent with overlapping balloon expandable drug eluting and bare metal stents in a porcine coronary model.
    Cilingiroglu M; Elliott J; Sangi P; Matthews H; Tio F; Trauthen B; Elicker J; Bailey SR
    EuroIntervention; 2009 Jan; 4(4):534-41. PubMed ID: 19284078
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A multicenter randomized comparison of drug-eluting balloon plus bare-metal stent versus bare-metal stent versus drug-eluting stent in bifurcation lesions treated with a single-stenting technique: six-month angiographic and 12-month clinical results of the drug-eluting balloon in bifurcations trial.
    Stella PR; Belkacemi A; Dubois C; Nathoe H; Dens J; Naber C; Adriaenssens T; van Belle E; Doevendans P; Agostoni P
    Catheter Cardiovasc Interv; 2012 Dec; 80(7):1138-46. PubMed ID: 22422607
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Acute and long-term outcomes of ostial stentings among bare-metal stents, sirolimus-eluting stents, and paclitaxel-eluting stents.
    Hsieh IC; Hsieh MJ; Chang SH; Wang CY; Lee CH; Lin FC; Chen CC
    Coron Artery Dis; 2013 May; 24(3):224-30. PubMed ID: 23571311
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Endothelial function rather than endothelial restoration is altered in paclitaxel- as compared to bare metal-, sirolimusand tacrolimus-eluting stents.
    van Beusekom HM; Sorop O; van den Heuvel M; Onuma Y; Duncker DJ; Danser AH; van der Giessen WJ
    EuroIntervention; 2010 May; 6(1):117-25. PubMed ID: 20542807
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Paclitaxcel-coated balloon plus bare metal stent vs. sirolimus-eluting stent in de novo lesions: an IVUS study.
    Fischer D; Scheller B; Schäfer A; Klein G; Böhm M; Clever Y; Cremers B
    EuroIntervention; 2012 Aug; 8(4):450-5. PubMed ID: 22917728
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Vasomotor function after paclitaxel-coated balloon post-dilation in porcine coronary stent model.
    Nakamura T; Brott BC; Brants I; Panchal D; Li J; Chen JP; King SB; Chronos N; Hou D
    JACC Cardiovasc Interv; 2011 Feb; 4(2):247-55. PubMed ID: 21349465
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A prospective randomised study using optical coherence tomography to assess endothelial coverage and neointimal proliferation at 6-months after implantation of a coronary everolimus-eluting stent compared with a bare metal stent postdilated with a paclitaxel-eluting balloon (OCTOPUS Trial): rationale, design and methods.
    Poerner TC; Otto S; Gassdorf J; Janiak F; Danzer C; Ferrari M; Figulla HR
    EuroIntervention; 2011 May; 7 Suppl K():K93-9. PubMed ID: 22027737
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Impact of Paclitaxel Dose on Tissue Pharmacokinetics and Vascular Healing: A Comparative Drug-Coated Balloon Study in the Familial Hypercholesterolemic Swine Model of Superficial Femoral In-Stent Restenosis.
    Gongora CA; Shibuya M; Wessler JD; McGregor J; Tellez A; Cheng Y; Conditt GB; Kaluza GL; Granada JF
    JACC Cardiovasc Interv; 2015 Jul; 8(8):1115-1123. PubMed ID: 26117470
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 21.