These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

419 related articles for article (PubMed ID: 22511557)

  • 21. A novel drug-coated scoring balloon for the treatment of coronary in-stent restenosis: Results from the multi-center randomized controlled PATENT-C first in human trial.
    Scheller B; Fontaine T; Mangner N; Hoffmann S; Bonaventura K; Clever YP; Chamie D; Costa R; Gershony G; Kelsch B; Kutschera M; Généreux P; Cremers B; Böhm M; Speck U; Abizaid A
    Catheter Cardiovasc Interv; 2016 Jul; 88(1):51-9. PubMed ID: 26331782
    [TBL] [Abstract][Full Text] [Related]  

  • 22. The union of anti-CD34 antibody can improve the performance of drug-eluting stents.
    Yang XS; Zhu HG; Yu ZJ; Ren F; Chen YQ; Wu X; Zhang ZC; Zhang LJ; Lu SZ
    Catheter Cardiovasc Interv; 2012 May; 79(6):972-8. PubMed ID: 22162277
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Paclitaxel-induced arterial wall toxicity and inflammation: part 2--long-term tissue response in a minipig model.
    Stampfl U; Radeleff B; Sommer C; Stampfl S; Lopez-Benitez R; Thierjung H; Kurz P; Berger I; Richter GM
    J Vasc Interv Radiol; 2009 Dec; 20(12):1608-16. PubMed ID: 19944986
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A multicenter randomized comparison of paclitaxel-coated balloon catheter with conventional balloon angioplasty in patients with bare-metal stent restenosis and drug-eluting stent restenosis.
    Habara S; Iwabuchi M; Inoue N; Nakamura S; Asano R; Nanto S; Hayashi Y; Shiode N; Saito S; Ikari Y; Kimura T; Hosokawa J; Nakamura M; Kotani J; Kozuma K; Mitsudo K
    Am Heart J; 2013 Sep; 166(3):527-33. PubMed ID: 24016503
    [TBL] [Abstract][Full Text] [Related]  

  • 25. The effect of shear stress on neointimal response following sirolimus- and paclitaxel-eluting stent implantation compared with bare-metal stents in humans.
    Papafaklis MI; Bourantas CV; Theodorakis PE; Katsouras CS; Naka KK; Fotiadis DI; Michalis LK
    JACC Cardiovasc Interv; 2010 Nov; 3(11):1181-9. PubMed ID: 21087755
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Paclitaxel-coated balloon catheter versus paclitaxel-coated stent for the treatment of coronary in-stent restenosis: the three-year results of the PEPCAD II ISR study.
    Unverdorben M; Vallbracht C; Cremers B; Heuer H; Hengstenberg C; Maikowski C; Werner GS; Antoni D; Kleber FX; Bocksch W; Leschke M; Ackermann H; Boxberger M; Speck U; Degenhardt R; Scheller B
    EuroIntervention; 2015 Dec; 11(8):926-34. PubMed ID: 25169589
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Recent progress in percutaneous coronary intervention: evolution of the drug-eluting stents, focus on the XIENCE V drug-eluting stent.
    Doostzadeh J; Clark LN; Bezenek S; Pierson W; Sood PR; Sudhir K
    Coron Artery Dis; 2010 Jan; 21(1):46-56. PubMed ID: 19952925
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Biological effect on restenosis and vascular healing of encapsulated paclitaxel nanocrystals delivered via coated balloon technology in the familial hypercholesterolaemic swine model of in-stent restenosis.
    Cheng Y; Shibuya M; McGregor J; Conditt GB; Yi GH; Kaluza GL; Gray W; Doshi M; Sojitra P; Granada JF
    EuroIntervention; 2016 Oct; 12(9):1164-1173. PubMed ID: 27753601
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Long-term safety and efficacy with paclitaxel-eluting stents: 5-year final results of the TAXUS IV clinical trial (TAXUS IV-SR: Treatment of De Novo Coronary Disease Using a Single Paclitaxel-Eluting Stent).
    Ellis SG; Stone GW; Cox DA; Hermiller J; O'Shaughnessy C; Mann T; Turco M; Caputo R; Bergin PJ; Bowman TS; Baim DS;
    JACC Cardiovasc Interv; 2009 Dec; 2(12):1248-59. PubMed ID: 20129552
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Paclitaxel-coated balloon in combination with bare metal stent for treatment of de novo coronary lesions: an optical coherence tomography first-in-human randomised trial, balloon first vs. stent first.
    Gutiérrez-Chico JL; van Geuns RJ; Koch KT; Koolen JJ; Duckers H; Regar E; Serruys PW
    EuroIntervention; 2011 Oct; 7(6):711-22. PubMed ID: 21986329
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Vascular response and mechanical integrity of the new biodegradable polymer coated sirolimus-eluting PROLIM stent implanted in porcine coronary arteries.
    Milewski K; Gorycki B; Buszman PP; Jelonek M; Beaudry D; Lapointe JM; Guy LG; Abusamra M; Pająk J; Kinasz W; Wojakowski W; Leclerc G; Gil RJ; Buszman PE
    Kardiol Pol; 2012; 70(7):703-11. PubMed ID: 22825946
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A randomized comparison of drug-eluting balloon versus everolimus-eluting stent in patients with bare-metal stent-in-stent restenosis: the RIBS V Clinical Trial (Restenosis Intra-stent of Bare Metal Stents: paclitaxel-eluting balloon vs. everolimus-eluting stent).
    Alfonso F; Pérez-Vizcayno MJ; Cárdenas A; García Del Blanco B; Seidelberger B; Iñiguez A; Gómez-Recio M; Masotti M; Velázquez MT; Sanchís J; García-Touchard A; Zueco J; Bethencourt A; Melgares R; Cequier A; Dominguez A; Mainar V; López-Mínguez JR; Moreu J; Martí V; Moreno R; Jiménez-Quevedo P; Gonzalo N; Fernández C; Macaya C;
    J Am Coll Cardiol; 2014 Apr; 63(14):1378-86. PubMed ID: 24412457
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Impact of drug-eluting balloon (pre- or post-) dilation on neointima formation in de novo lesions treated by bare-metal stent: the IN-PACT CORO trial.
    Burzotta F; Brancati MF; Trani C; Pirozzolo G; De Maria G; Leone AM; Niccoli G; Porto I; Prati F; Crea F
    Heart Vessels; 2016 May; 31(5):677-86. PubMed ID: 25863804
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Late Restenosis After Paclitaxel-Coated Balloon Angioplasty Occurs in Patients With Drug-Eluting Stent Restenosis.
    Habara S; Kadota K; Shimada T; Ohya M; Amano H; Izawa Y; Kubo S; Hyodo Y; Otsuru S; Hasegawa D; Tada T; Tanaka H; Fuku Y; Goto T; Mitsudo K
    J Am Coll Cardiol; 2015 Jul; 66(1):14-22. PubMed ID: 26139053
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Long-term clinical outcomes after treatment of stent restenosis with two drug-coated balloons.
    Schröder J; Vogt F; Burgmaier M; Reith S; Almalla M
    Coron Artery Dis; 2018 Dec; 29(8):632-637. PubMed ID: 30273183
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Feasibility, safety, and efficacy of a novel polymeric pimecrolimus-eluting stent: traditional pre-clinical safety end points failed to predict 6-month clinical angiographic results.
    Ormiston JA; Webster MW; Schwartz RS; Gladding P; Stewart JT; Kay IP; Ruygrok PN; Hatrick R
    JACC Cardiovasc Interv; 2009 Oct; 2(10):1017-24. PubMed ID: 19850264
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Randomized evaluation of two drug-eluting stents with identical metallic platform and biodegradable polymer but different agents (paclitaxel or sirolimus) compared against bare stents: 1-year results of the PAINT trial.
    Lemos PA; Moulin B; Perin MA; Oliveira LA; Arruda JA; Lima VC; Lima AA; Caramori PR; Medeiros CR; Barbosa MR; Brito FS; Ribeiro EE; Martinez EE;
    Catheter Cardiovasc Interv; 2009 Nov; 74(5):665-73. PubMed ID: 19670303
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Do pharmacokinetics explain persistent restenosis inhibition by a single dose of paclitaxel?
    Speck U; Cremers B; Kelsch B; Biedermann M; Clever YP; Schaffner S; Mahnkopf D; Hanisch U; Böhm M; Scheller B
    Circ Cardiovasc Interv; 2012 Jun; 5(3):392-400. PubMed ID: 22619258
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Elutax paclitaxel-eluting balloon followed by bare-metal stent compared with Xience V drug-eluting stent in the treatment of de novo coronary stenosis: a randomized trial.
    Liistro F; Porto I; Angioli P; Grotti S; Ducci K; Falsini G; Bolognese L
    Am Heart J; 2013 Nov; 166(5):920-6. PubMed ID: 24176449
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Drug-eluting balloon: very short-term exposure and overlapping.
    Cremers B; Speck U; Kaufels N; Mahnkopf D; Kühler M; Böhm M; Scheller B
    Thromb Haemost; 2009 Jan; 101(1):201-6. PubMed ID: 19132209
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 21.