363 related articles for article (PubMed ID: 22513883)
1. A comparison of different energy window subtraction methods to correct for scatter and downscatter in I-123 SPECT imaging.
Lagerburg V; de Nijs R; Holm S; Svarer C
Nucl Med Commun; 2012 Jul; 33(7):708-18. PubMed ID: 22513883
[TBL] [Abstract][Full Text] [Related]
2. Improving quantitative dosimetry in (177)Lu-DOTATATE SPECT by energy window-based scatter corrections.
de Nijs R; Lagerburg V; Klausen TL; Holm S
Nucl Med Commun; 2014 May; 35(5):522-33. PubMed ID: 24525900
[TBL] [Abstract][Full Text] [Related]
3. Hybrid scatter correction applied to quantitative holmium-166 SPECT.
de Wit TC; Xiao J; Nijsen JF; van het Schip FD; Staelens SG; van Rijk PP; Beekman FJ
Phys Med Biol; 2006 Oct; 51(19):4773-87. PubMed ID: 16985270
[TBL] [Abstract][Full Text] [Related]
4. Analytically based photon scatter modeling for a multipinhole cardiac SPECT camera.
Pourmoghaddas A; Wells RG
Med Phys; 2016 Nov; 43(11):6098. PubMed ID: 27806581
[TBL] [Abstract][Full Text] [Related]
5. Effect of dual and triple energy window scatter correction methods on image quality in liver scintigraphy.
Perisinakis K; Karkavitsas N; Damilakis J; Gourtsoyiannis N
Nuklearmedizin; 1998; 37(7):239-44. PubMed ID: 9830614
[TBL] [Abstract][Full Text] [Related]
6. A modified TEW approach to scatter correction for In-111 and Tc-99m dual-isotope small-animal SPECT.
Prior P; Timmins R; Petryk J; Strydhorst J; Duan Y; Wei L; Glenn Wells R
Med Phys; 2016 Oct; 43(10):5503. PubMed ID: 27782731
[TBL] [Abstract][Full Text] [Related]
7. Optimized energy window configuration for 201Tl imaging.
Kalantari F; Rajabi H; Yaghoobi N
J Nucl Med Technol; 2008 Mar; 36(1):36-43. PubMed ID: 18287194
[TBL] [Abstract][Full Text] [Related]
8. Downscatter correction and choice of collimator in 123I imaging.
Small AD; Prosser J; Motherwell DW; McCurrach GM; Fletcher AM; Martin W
Phys Med Biol; 2006 Sep; 51(17):N307-11. PubMed ID: 16912369
[TBL] [Abstract][Full Text] [Related]
9. The effect of scatter correction on planar and tomographic semiquantitative
Papanastasiou E; Moralidis E; Siountas A
Hell J Nucl Med; 2017; 20(2):154-159. PubMed ID: 28777833
[TBL] [Abstract][Full Text] [Related]
10. Scatter and crosstalk corrections for (99m)Tc/(123)I dual-radionuclide imaging using a CZT SPECT system with pinhole collimators.
Fan P; Hutton BF; Holstensson M; Ljungberg M; Pretorius PH; Prasad R; Ma T; Liu Y; Wang S; Thorn SL; Stacy MR; Sinusas AJ; Liu C
Med Phys; 2015 Dec; 42(12):6895-911. PubMed ID: 26632046
[TBL] [Abstract][Full Text] [Related]
11. Correction of photon attenuation and collimator response for a body-contouring SPECT/CT imaging system.
Seo Y; Wong KH; Sun M; Franc BL; Hawkins RA; Hasegawa BH
J Nucl Med; 2005 May; 46(5):868-77. PubMed ID: 15872362
[TBL] [Abstract][Full Text] [Related]
12. Photon energy recovery: a method to improve the effective energy resolution of gamma cameras.
Hannequin PP; Mas JF
J Nucl Med; 1998 Mar; 39(3):555-62. PubMed ID: 9529311
[TBL] [Abstract][Full Text] [Related]
13. Impact of scatter and attenuation corrections for iodine-131 two-dimensional quantitative imaging in patients.
Delpon G; Ferrer L; Lisbona A; Bardiès M
Cancer Biother Radiopharm; 2003 Apr; 18(2):191-9. PubMed ID: 12804044
[TBL] [Abstract][Full Text] [Related]
14. Evaluation of three scatter correction methods based on estimation of photopeak scatter spectrum in SPECT imaging: a simulation study.
Noori-Asl M; Sadremomtaz A; Bitarafan-Rajabi A
Phys Med; 2014 Dec; 30(8):947-53. PubMed ID: 24985135
[TBL] [Abstract][Full Text] [Related]
15. Model-based compensation for quantitative 123I brain SPECT imaging.
Du Y; Tsui BM; Frey EC
Phys Med Biol; 2006 Mar; 51(5):1269-82. PubMed ID: 16481693
[TBL] [Abstract][Full Text] [Related]
16. Energy dependence of nonstationary scatter subtraction--restoration in high resolution PET.
Bentourkia M; Lecomte R
IEEE Trans Med Imaging; 1999 Jan; 18(1):66-73. PubMed ID: 10193698
[TBL] [Abstract][Full Text] [Related]
17. Three-window transformation cross-talk correction for simultaneous dual-isotope imaging.
Knesaurek K; Machac J
J Nucl Med; 1997 Dec; 38(12):1992-8. PubMed ID: 9430484
[TBL] [Abstract][Full Text] [Related]
18. Characterization of scatter and penetration using Monte Carlo simulation in 131I imaging.
Dewaraja YK; Ljungberg M; Koral KF
J Nucl Med; 2000 Jan; 41(1):123-30. PubMed ID: 10647615
[TBL] [Abstract][Full Text] [Related]
19. Development and evaluation of a model-based downscatter compensation method for quantitative I-131 SPECT.
Song N; Du Y; He B; Frey EC
Med Phys; 2011 Jun; 38(6):3193-204. PubMed ID: 21815394
[TBL] [Abstract][Full Text] [Related]
20. [Scatter correction with an off-peak triple energy window method in thallium-201 imaging].
Kojima A; Matsumoto M; Ohyama Y; Tomiguchi S; Kira M; Takahashi M
Kaku Igaku; 1997 Sep; 34(9):789-96. PubMed ID: 9394545
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]