These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
441 related articles for article (PubMed ID: 22515960)
1. Comparison of Sebia Capillarys Flex capillary electrophoresis with the BioRad Variant II high pressure liquid chromatography in the evaluation of hemoglobinopathies. Greene DN; Pyle AL; Chang JS; Hoke C; Lorey T Clin Chim Acta; 2012 Aug; 413(15-16):1232-8. PubMed ID: 22515960 [TBL] [Abstract][Full Text] [Related]
2. Comparison of Sebia Capillarys capillary electrophoresis with the Primus high-pressure liquid chromatography in the evaluation of hemoglobinopathies. Keren DF; Hedstrom D; Gulbranson R; Ou CN; Bak R Am J Clin Pathol; 2008 Nov; 130(5):824-31. PubMed ID: 18854277 [TBL] [Abstract][Full Text] [Related]
3. Multicenter validation of fully automated capillary electrophoresis method for diagnosis of thalassemias and hemoglobinopathies in Thailand. Sangkitporn S; Sangkitporn SK; Tanjatham S; Suwannakan B; Rithapirom S; Yodtup C; Yowang A; Duangruang S Southeast Asian J Trop Med Public Health; 2011 Sep; 42(5):1224-32. PubMed ID: 22299449 [TBL] [Abstract][Full Text] [Related]
4. Hemoglobin fractionation by Sebia Capillarys 2 Flex Piercing System as primary method for evaluation of hemoglobinopathies. Poventud-Fuentes I; Garnett E; Vispo B; Elghetany MT; Devaraj S Clin Chim Acta; 2021 Aug; 519():193-197. PubMed ID: 33939955 [TBL] [Abstract][Full Text] [Related]
5. Evaluation of the Sebia Minicap Flex Piercing capillary electrophoresis for hemoglobinopathy testing. Oyaert M; Van Laer C; Claerhout H; Vermeersch P; Desmet K; Pauwels S; Kieffer D Int J Lab Hematol; 2015 Jun; 37(3):420-5. PubMed ID: 25324031 [TBL] [Abstract][Full Text] [Related]
6. Identification and quantification of hemoglobins in whole blood: the analytical and organizational aspects of Capillarys 2 Flex Piercing compared with agarose electrophoresis and HPLC methods. Altinier S; Varagnolo M; Zaninotto M; Plebani M Clin Chem Lab Med; 2013 Apr; 51(4):791-7. PubMed ID: 23072852 [TBL] [Abstract][Full Text] [Related]
7. Evaluation of an automated capillary electrophoresis system in the screening for hemoglobinopathies. Cotton F; Malaviolle X; Vertongen F; Gulbis B Clin Lab; 2009; 55(5-6):217-21. PubMed ID: 19728555 [TBL] [Abstract][Full Text] [Related]
8. Capillary Electrophoresis Resolves Inconclusive HPLC Analysis for Hemoglobin Variants: a Study of Two Cases. Li Y; Tian M; Qin T; Wan L Clin Lab; 2018 Jul; 64(7):1305-1309. PubMed ID: 30146834 [TBL] [Abstract][Full Text] [Related]
9. Diagnosis of a rare double heterozygous Hb D Punjab/Hb Q India hemoglobinopathy using Sebia capillary zone electrophoresis. Parab S; Sakhare S; Sengupta C; Velumani A Indian J Pathol Microbiol; 2014; 57(4):626-8. PubMed ID: 25308024 [TBL] [Abstract][Full Text] [Related]
10. A comparative evaluation of the analytical performances of premier resolution-high-performance liquid chromatography (PR-HPLC) with capillary zone electrophoresis (CZE) assays for the detection of hemoglobin variants and the quantitation of HbA Laksap S; Suanboon S; Punyamung M; Ruengdit C; Pornprasert S Clin Chem Lab Med; 2024 Jun; 62(7):1383-1392. PubMed ID: 38197862 [TBL] [Abstract][Full Text] [Related]
11. Comparison of two methods for the quantification and identification of hemoglobin variants. Higgins T; Mack M; Khajuria A Clin Biochem; 2009 May; 42(7-8):701-5. PubMed ID: 19318037 [TBL] [Abstract][Full Text] [Related]
12. Evaluation of a new Sebia kit for analysis of hemoglobin fractions and variants on the Capillarys system. Louahabi A; Philippe M; Lali S; Wallemacq P; Maisin D Clin Chem Lab Med; 2006; 44(3):340-5. PubMed ID: 16519609 [TBL] [Abstract][Full Text] [Related]
13. Quantification of HbA(2) in patients with and without beta-thalassemia and in the presence of HbS, HbC, HbE, and HbD Punjab hemoglobin variants: comparison of two systems. Higgins TN; Khajuria A; Mack M Am J Clin Pathol; 2009 Mar; 131(3):357-62. PubMed ID: 19233839 [TBL] [Abstract][Full Text] [Related]
14. Hemoglobin typing by high performance liquid chromatography. Tatu T; Gategasem P; Hathirat P Southeast Asian J Trop Med Public Health; 1997 Jun; 28(2):417-23. PubMed ID: 9444032 [TBL] [Abstract][Full Text] [Related]
16. Analytical evaluation of the Capillarys 2 Flex piercing for routine haemoglobinopathies diagnosis. Agouti I; Merono F; Bonello-Palot N; Badens C Int J Lab Hematol; 2013 Apr; 35(2):217-21. PubMed ID: 22943067 [TBL] [Abstract][Full Text] [Related]
17. The validation of an automated liquid chromatography system for the diagnosis of thalassemias and hemoglobinopathies. Sangkitporn S; Pung-amritt P; Sangkitporn SK; Sangnoi A; Tanphaichitr VS Southeast Asian J Trop Med Public Health; 2002 Dec; 33(4):862-8. PubMed ID: 12757240 [TBL] [Abstract][Full Text] [Related]
18. Evaluation of four hemoglobin separation analyzers for hemoglobinopathy diagnosis. Degandt S; Coens R; Cauwelier B; Devos H; Langlois M; Emmerechts J J Clin Lab Anal; 2018 Jan; 32(1):. PubMed ID: 28383138 [TBL] [Abstract][Full Text] [Related]
19. Analytical evaluation of the Tosoh HLC-723 G7 automated HPLC analyzer for hemoglobin A2 and F determination. Paleari R; Cannata M; Leto F; Maggio A; Demartis FR; Desogus MF; Galanello R; Mosca A Clin Biochem; 2005 Feb; 38(2):159-65. PubMed ID: 15642279 [TBL] [Abstract][Full Text] [Related]
20. Evaluation of the V8 E-Class, a Novel Automated Capillary Isoelectric Focusing Instrument for Hemoglobinopathy Screening. Schiemsky T; Brusselmans C; Nackers E; Vermeersch P; Poesen K; Desmet KJ; Boeckx N; Kieffer DM Am J Clin Pathol; 2016 Sep; 146(3):361-8. PubMed ID: 27543981 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]