These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

106 related articles for article (PubMed ID: 2251705)

  • 1. [The biomechanical characteristics of the instruments for preparing the bone bed for cylindrical implants].
    Paraskevich VL
    Stomatologiia (Mosk); 1990; (4):57-9. PubMed ID: 2251705
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effect of speed, pressure, and time on bone temperature during the drilling of implant sites.
    Brisman DL
    Int J Oral Maxillofac Implants; 1996; 11(1):35-7. PubMed ID: 8820120
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Heat generation during implant site preparation: an in vitro study.
    Cordioli G; Majzoub Z
    Int J Oral Maxillofac Implants; 1997; 12(2):186-93. PubMed ID: 9109268
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Infrared thermographic evaluation of temperature modifications induced during implant site preparation with cylindrical versus conical drills.
    Scarano A; Piattelli A; Assenza B; Carinci F; Di Donato L; Romani GL; Merla A
    Clin Implant Dent Relat Res; 2011 Dec; 13(4):319-23. PubMed ID: 19681941
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Therapy of the severely atrophied mandible].
    Bert M
    Int J Dent Symp; 1994; 2(1):52-5. PubMed ID: 9117854
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effects of drill speed on heat production and the rate and quality of bone formation in dental implant osteotomies. Part II: Relationship between drill speed and healing.
    Iyer S; Weiss C; Mehta A
    Int J Prosthodont; 1997; 10(6):536-40. PubMed ID: 9495174
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [An experimental verification of the thermal changes in the bone tissue during drilling for cavity preparation for an endosseous implant].
    Fagnoni V; Fontolan D; Polastri F; Zucca M
    Minerva Stomatol; 1991; 40(1-2):9-13. PubMed ID: 2041537
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Osteotomy irrigation: is it necessary?
    Flanagan D
    Implant Dent; 2010 Jun; 19(3):241-9. PubMed ID: 20523180
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Atraumatic surgical technique and implant bed preparation.
    Sutter F; Krekeler G; Schwammberger AE; Sutter FJ
    Quintessence Int; 1992 Dec; 23(12):811-6. PubMed ID: 1305298
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Heat production by 3 implant drill systems after repeated drilling and sterilization.
    Chacon GE; Bower DL; Larsen PE; McGlumphy EA; Beck FM
    J Oral Maxillofac Surg; 2006 Feb; 64(2):265-9. PubMed ID: 16413899
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effects of irrigation temperature on heat control in vitro at different drilling depths.
    Sener BC; Dergin G; Gursoy B; Kelesoglu E; Slih I
    Clin Oral Implants Res; 2009 Mar; 20(3):294-8. PubMed ID: 19397641
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of surgical drill guide on heat generated from implant drilling.
    Misir AF; Sumer M; Yenisey M; Ergioglu E
    J Oral Maxillofac Surg; 2009 Dec; 67(12):2663-8. PubMed ID: 19925988
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Study on method for examining bone quality for dental implant. Relationship between cutting force and bone mineral content].
    Sugaya K
    Shikwa Gakuho; 1990 Apr; 90(4):607-33. PubMed ID: 2135501
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effects of a Short Drilling Implant Protocol on Osteotomy Site Temperature and Drill Torque.
    Mihali SG; Canjau S; Cernescu A; Bortun CM; Wang HL; Bratu E
    Implant Dent; 2018 Feb; 27(1):63-68. PubMed ID: 29200004
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Slow drilling speeds for single-drill implant bed preparation. Experimental in vitro study.
    Delgado-Ruiz RA; Velasco Ortega E; Romanos GE; Gerhke S; Newen I; Calvo-Guirado JL
    Clin Oral Investig; 2018 Jan; 22(1):349-359. PubMed ID: 28434045
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The tri-spade drill for endosseous dental implant installation.
    Kay JF; Gilman L; May TC
    J Oral Implantol; 1991; 17(4):424-8. PubMed ID: 1813652
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Influence of defect depth on resonance frequency analysis and insertion torque values for implants placed in fresh extraction sockets: a human cadaver study.
    Turkyilmaz I; Sennerby L; Yilmaz B; Bilecenoglu B; Ozbek EN
    Clin Implant Dent Relat Res; 2009 Mar; 11(1):52-8. PubMed ID: 18384400
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of surgical techniques on primary implant stability and peri-implant bone.
    Fanuscu MI; Chang TL; Akça K
    J Oral Maxillofac Surg; 2007 Dec; 65(12):2487-91. PubMed ID: 18022474
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Influence of surgical technique and surface roughness on the primary stability of an implant in artificial bone with different cortical thickness: a laboratory study.
    Tabassum A; Meijer GJ; Wolke JG; Jansen JA
    Clin Oral Implants Res; 2010 Feb; 21(2):213-20. PubMed ID: 20070754
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effects of mechanical and thermal fatigue on dental drill performance.
    Harris BH; Kohles SS
    Int J Oral Maxillofac Implants; 2001; 16(6):819-26. PubMed ID: 11769832
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.