148 related articles for article (PubMed ID: 2252668)
1. Development of an efficient electrohydraulic total artificial heart.
Millner A; Menn D; Ochs B; Vaughan S; Kung RT
ASAIO Trans; 1990; 36(3):M245-9. PubMed ID: 2252668
[TBL] [Abstract][Full Text] [Related]
2. Another way of pumping blood with a rotary but noncentrifugal pump for an artificial heart.
Monties JR; Mesana T; Havlik P; Trinkl J; Demunck JL; Candelon B
ASAIO Trans; 1990; 36(3):M258-60. PubMed ID: 2252672
[TBL] [Abstract][Full Text] [Related]
3. A compact and noise free electrohydraulic total artificial heart.
Yu LS; Finnegan M; Vaughan S; Ochs B; Parnis S; Frazier OH; Kung RT
ASAIO J; 1993; 39(3):M386-91. PubMed ID: 8268564
[TBL] [Abstract][Full Text] [Related]
4. Development of the E4T electrohydraulic total artificial heart.
Himley SC; Butler KC; Massiello A; Chen J; Irie H; Harasaki H; Kiraly RJ; Golding L; Takatani S; Nosé Y
ASAIO Trans; 1990; 36(3):M234-7. PubMed ID: 2252665
[TBL] [Abstract][Full Text] [Related]
5. An atrial hydraulic shunt in a total artificial heart. A balance mechanism for the bronchial shunt.
Kung RT; Yu LS; Ochs B; Parnis S; Frazier OH
ASAIO J; 1993; 39(3):M213-7. PubMed ID: 8268531
[TBL] [Abstract][Full Text] [Related]
6. In vitro analysis of an atrial shunt in balancing an electrohydraulic total artificial heart.
Crump KR; Khanwilkar PS; Long JW; Holfert JW; Olsen DB
ASAIO Trans; 1990; 36(3):M254-7. PubMed ID: 2252671
[TBL] [Abstract][Full Text] [Related]
7. An electrohydraulic total artificial heart with a separately placed actuator.
Taenaka Y; Sekii H; Tatsumi E; Nakatani T; Sasaki E; Yagura A; Akagi H; Masuzawa T; Goto M; Matsuo Y
ASAIO Trans; 1990; 36(3):M242-5. PubMed ID: 2252667
[TBL] [Abstract][Full Text] [Related]
8. In vivo long-term evaluation of the Utah electrohydraulic total artificial heart.
Tatsumi E; Khanwilkar PS; Rowles JR; Chiang BY; Burns GL; Long JW; Hansen AC; Holfert JW; Bearnson GB; Crump KR
ASAIO J; 1993; 39(3):M373-80. PubMed ID: 8268562
[TBL] [Abstract][Full Text] [Related]
9. An annular compliance chamber for the Pennsylvania State University electric total artificial heart.
Reibson JD; Rosenberg G; Snyder AJ; Cleary TJ; Donachy JH; Felder G; Pierce WS
ASAIO J; 1993; 39(3):M415-8. PubMed ID: 8268569
[TBL] [Abstract][Full Text] [Related]
10. Findlay implantable two-stage centrifugal pump.
Moulder PV; Findlay IS; Zone RM; Thompson AJ; Silber HA; Rank WR; Charbonnet MD; Webb WR; Harrison LH
Artif Organs; 1996 Jun; 20(6):503-12. PubMed ID: 8817947
[TBL] [Abstract][Full Text] [Related]
11. Determination of atrial shunt size needed to balance an electrohydraulic total artificial heart.
Kinoshita M; Hansen CA; Khanwilkar PS; White KR; Olsen DB
ASAIO Trans; 1991; 37(3):M264-5. PubMed ID: 1751140
[TBL] [Abstract][Full Text] [Related]
12. Pressures generated within the chambers of the MagScrew TAH: an in vitro study.
Flick CR; Weber S; Luangphakdy V; Klatte RS; Fukamachi K; Smith WA
ASAIO J; 2008; 54(1):58-63. PubMed ID: 18204317
[TBL] [Abstract][Full Text] [Related]
13. The Cleveland Clinic-Nimbus total artificial heart. Design and in vitro function.
Massiello A; Kiraly R; Butler K; Himley S; Chen JF; McCarthy PM
J Thorac Cardiovasc Surg; 1994 Sep; 108(3):412-9. PubMed ID: 8078334
[TBL] [Abstract][Full Text] [Related]
14. Effect of pressure-flow relationship of centrifugal pump on in vivo hemodynamics: a consideration for design.
Tagusari O; Yamazaki K; Litwak P; Antaki JF; Watach M; Gordon LM; Kono K; Mori T; Koyanagi H; Griffith BP; Kormos RL
Artif Organs; 1998 May; 22(5):399-404. PubMed ID: 9609348
[TBL] [Abstract][Full Text] [Related]
15. Development of the undulation pump total artificial heart.
Abe Y; Chinzei T; Isoyama T; Ono T; Mochizuki S; Mabuchi K; Baba K; Matsuura H; Sun YP; Kouno A; Atsumi K; Fujimasa I; Imachi K
Artif Organs; 1997 Jul; 21(7):665-9. PubMed ID: 9212936
[TBL] [Abstract][Full Text] [Related]
16. A new pulsatile total artificial heart using a single centrifugal pump.
Imachi K; Chinzei T; Abe Y; Mabuchi K; Imanishi K; Yonezawa T; Kouno A; Ono T; Atsumi K; Isoyama T
ASAIO Trans; 1991; 37(3):M242-3. PubMed ID: 1751129
[TBL] [Abstract][Full Text] [Related]
17. Chronic in vivo evaluation of an electrohydraulic total artificial heart.
Parnis SM; Yu LS; Ochs BD; Macris MP; Frazier OH; Kung RT
ASAIO J; 1994; 40(3):M489-93. PubMed ID: 8555564
[TBL] [Abstract][Full Text] [Related]
18. Development of an electrohydraulic total artificial heart at the National Cardiovascular Center, Osaka, Japan.
Masuzawa T; Taenaka Y; Tatsumi E; Choi WW; Toda K; Ohno T; Baba Y; Nakatani T; Takano H; Uyama C
ASAIO J; 1995; 41(3):M249-53. PubMed ID: 8573799
[TBL] [Abstract][Full Text] [Related]
19. Soft artificial ventricles for infants and adults, with or without a clamshell.
Yu LS; Versteeg F; Kinoshita M; Yuan B; Bishop N; Torgerson T; Topaz S; Kolff WJ
ASAIO Trans; 1990; 36(3):M238-42. PubMed ID: 2252666
[TBL] [Abstract][Full Text] [Related]
20. Set-up, improvement, and evaluation of an electrohydraulic total artificial heart with a separately placed energy converter.
Masuzawa T; Taenaka Y; Tatsumi E; Ahn JM; Ohno T; Toda K; Miyazaki K; Wakisaka Y; Eya K; Baba Y; Nakatani T; Takano H; Uyama C; Koshiji K; Fukui Y; Takahashi K; Tsuchimoto K; Tsukahara K
ASAIO J; 1996; 42(5):M328-32. PubMed ID: 8944900
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]