These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 2252671)

  • 1. In vitro analysis of an atrial shunt in balancing an electrohydraulic total artificial heart.
    Crump KR; Khanwilkar PS; Long JW; Holfert JW; Olsen DB
    ASAIO Trans; 1990; 36(3):M254-7. PubMed ID: 2252671
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Right-left ventricular balance in implanted electrically powered artificial hearts.
    Long JW; Khanwilkar P; Crump KR; Pantalos GM; Kinoshita M; Kim HC; Olsen DB
    ASAIO Trans; 1990; 36(3):M287-90. PubMed ID: 2252680
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Determination of atrial shunt size needed to balance an electrohydraulic total artificial heart.
    Kinoshita M; Hansen CA; Khanwilkar PS; White KR; Olsen DB
    ASAIO Trans; 1991; 37(3):M264-5. PubMed ID: 1751140
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An atrial hydraulic shunt in a total artificial heart. A balance mechanism for the bronchial shunt.
    Kung RT; Yu LS; Ochs B; Parnis S; Frazier OH
    ASAIO J; 1993; 39(3):M213-7. PubMed ID: 8268531
    [TBL] [Abstract][Full Text] [Related]  

  • 5. In vitro and in vivo evaluation of a left-right balancing capacity of an interatrial shunt in an electrohydraulic total artificial heart system.
    Tatsumi E; Nakamura M; Masuzawa T; Taenaka Y; Sohn YS; Nishimura T; Nakata M; Nakatani T; Ohno T; Endo S; Takiura K; Takewa Y; Kakuta Y; Takano H
    ASAIO J; 1997; 43(5):M619-25. PubMed ID: 9360119
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In vitro development of automatic control for the actively filled electrohydraulic heart.
    Lioi AP; Orth JL; Crump KR; Diffee G; Dew PA; Nielsen SD; Olsen DB
    Artif Organs; 1988 Apr; 12(2):152-62. PubMed ID: 3291829
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Right-left ventricular output balance in the totally implantable artificial heart.
    Olsen DB; White RK; Long JW; Khanwilkar PS
    Int J Artif Organs; 1991 Jun; 14(6):359-64. PubMed ID: 1885244
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In vivo long-term evaluation of the Utah electrohydraulic total artificial heart.
    Tatsumi E; Khanwilkar PS; Rowles JR; Chiang BY; Burns GL; Long JW; Hansen AC; Holfert JW; Bearnson GB; Crump KR
    ASAIO J; 1993; 39(3):M373-80. PubMed ID: 8268562
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Cardiac output regulation in the moving actuator total artificial heart without a compliance chamber.
    Kim HC; Min BG
    ASAIO J; 1992; 38(4):846-50. PubMed ID: 1450484
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Flow balance between the left and right cardiac output of an eccentric roller type total artificial heart.
    Wada H; Fukunaga S; Watari M; Sakai H; Sugawara Y; Ochikubo H; Imai K; Shibamura H; Orihashi K; Sueda T; Matsuura Y
    Artif Organs; 1999 Aug; 23(8):741-6. PubMed ID: 10463500
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A blood pump with an interatrial shunt for use as an electrohydraulic total artificial heart.
    Tatsumi E; Diegel PD; Holfert JW; Dew PA; Crump KR; Hansen AC; Khanwilkar PS; Rowles JR; Olsen DB
    ASAIO J; 1992; 38(3):M425-30. PubMed ID: 1457895
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Development of an automatic control algorithm for the electrohydraulic total artificial heart without transducers.
    Kim HC; Khanwilkar PS; Crump KC; Smith KD; Bearnson GB; Olsen DB
    ASAIO Trans; 1991; 37(3):M501-3. PubMed ID: 1751252
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development of an efficient electrohydraulic total artificial heart.
    Millner A; Menn D; Ochs B; Vaughan S; Kung RT
    ASAIO Trans; 1990; 36(3):M245-9. PubMed ID: 2252668
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effects of an interatrial shunt on rest and exercise hemodynamics: results of a computer simulation in heart failure.
    Kaye D; Shah SJ; Borlaug BA; Gustafsson F; Komtebedde J; Kubo S; Magnin C; Maurer MS; Feldman T; Burkhoff D
    J Card Fail; 2014 Mar; 20(3):212-21. PubMed ID: 24487087
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of a total artificial heart right stroke volume limiter on left-right hemodynamic balance.
    Fukamachi K; Massiello AL; Kiraly RJ; Chen JF; Himley S; Davies C; Fukumura F; Muramoto K; Olsen E; Golding LA
    ASAIO J; 1993; 39(3):M410-4. PubMed ID: 8268568
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Modified Fontan procedure, is the right atrial pump function necessary or not? Experimental approach using simulation model].
    Tamaki S; Kawazoe K; Yagihara T; Abe T
    Nihon Kyobu Geka Gakkai Zasshi; 1991 Nov; 39(11):2023-8. PubMed ID: 1774480
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Acute pressure overload of the right ventricle. Comparison of two models of right-left shunt. Pulmonary artery to left atrium and right atrium to left atrium: experimental study.
    Argiriou M; Mikroulis D; Sakellaridis T; Didilis V; Papalois A; Bougioukas G
    J Cardiothorac Surg; 2011 Oct; 6():143. PubMed ID: 22011551
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Prediction of haemodynamics after interatrial shunt for heart failure using the generalized circulatory equilibrium.
    Nishikawa T; Saku K; Uike K; Uemura K; Sunagawa G; Tohyama T; Yoshida K; Kishi T; Sunagawa K; Tsutsui H
    ESC Heart Fail; 2020 Oct; 7(5):3075-3085. PubMed ID: 32750231
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The Cleveland Clinic-Nimbus total artificial heart. Design and in vitro function.
    Massiello A; Kiraly R; Butler K; Himley S; Chen JF; McCarthy PM
    J Thorac Cardiovasc Surg; 1994 Sep; 108(3):412-9. PubMed ID: 8078334
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Vascular tone estimation in patients implanted with the AbioCor implantable replacement heart.
    Kung RT; Zhang H
    Artif Organs; 2004 Jun; 28(6):543-8. PubMed ID: 15153146
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.