These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

115 related articles for article (PubMed ID: 2252674)

  • 1. Factors influencing the accuracy of the cardiac output monitoring and diagnostic unit for pneumatic artificial hearts.
    Shaw WJ; Pantalos GM; Everett S; Olsen DB
    ASAIO Trans; 1990; 36(3):M264-8. PubMed ID: 2252674
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Continuous monitoring of artificial heart pump performance.
    Sasaki E; Nakatani T; Taenaka Y; Noda H; Tatsumi E; Akagi H; Masuzawa T; Goto M; Sakaki M; Matsuo Y
    ASAIO Trans; 1991; 37(3):M429-30. PubMed ID: 1751222
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vitro testing of a new driver for the pneumatic total artificial heart with inherent cardiac output measuring system.
    Frumento CI; Auch WD; Frumento AS
    Med Prog Technol; 1983-1984; 10(2):97-107. PubMed ID: 6674739
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [A computer-assisted noninvasive monitoring system with graphic display of online determination of cardiovascular parameters].
    Castor G; Motsch J; Altmayer P; Molter G
    Biomed Tech (Berl); 1989 Nov; 34(11):262-7. PubMed ID: 2605290
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Complex processing of sensor values].
    Mio H; Wiesspeiner G; Wach P; Kontschieder H; Marsoner H; Skrabal F; Kotanko P
    Biomed Tech (Berl); 1990; 35 Suppl 2():175-6. PubMed ID: 2223979
    [No Abstract]   [Full Text] [Related]  

  • 6. In vitro, in vivo and numerical assessment of the working principle of the truCCOMS continuous cardiac output catheter system.
    Claessens T; Verwilst P; Missant C; Claus P; Verdonck P; Wouters P; Segers P
    Med Eng Phys; 2009 Dec; 31(10):1299-306. PubMed ID: 19767233
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A transcutaneous optical information transmission system for implantable motor-driven artificial hearts.
    Mitamura Y; Okamoto E; Mikami T
    ASAIO Trans; 1990; 36(3):M278-80. PubMed ID: 2252677
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Automatic monitoring system for artificial hearts using self organizing map.
    Wang XZ; Yoshizawa M; Tanaka A; Abe KI; Yambe T; Nitta S; Chinzei T; Abe Y; Imachi K
    ASAIO J; 2001; 47(6):686-91. PubMed ID: 11730212
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Calculating arterial pressure-based cardiac output using a novel measurement and analysis method.
    Pratt B; Roteliuk L; Hatib F; Frazier J; Wallen RD
    Biomed Instrum Technol; 2007; 41(5):403-11. PubMed ID: 17992808
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Non-invasive continuous monitoring of heart function using miniaturized scintillation detectors and attached computer system].
    Fridrich L; Heute D; Mutz N; Benzer H; Stöger A; Klicpera M; Riccabona G
    Biomed Tech (Berl); 1990; 35 Suppl 2():57-8. PubMed ID: 2224027
    [No Abstract]   [Full Text] [Related]  

  • 11. Continuous cardiac output monitoring system.
    Tjin SC; Ho YC; Lam YZ; Hao J; Ng BK
    Med Biol Eng Comput; 2001 Jan; 39(1):101-4. PubMed ID: 11214260
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Recent developments in position sensors].
    Schaldach M; Bolz A; Jirmann J; Hutten H
    Biomed Tech (Berl); 1990; 35 Suppl 3():207-9. PubMed ID: 2078699
    [No Abstract]   [Full Text] [Related]  

  • 13. Continuous registration of cardiac output with a new computer system designed for hot-film anemometry: an in vitro study.
    Hasenkam JM; Ostergaard JH; Pedersen EM; Paulsen PK; Nissen T
    Life Support Syst; 1986; 4(4):335-44. PubMed ID: 2951566
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Edwards FloTrac sensor and Vigileo monitor: easy, accurate, reliable cardiac output assessment using the arterial pulse wave.
    Manecke GR
    Expert Rev Med Devices; 2005 Sep; 2(5):523-7. PubMed ID: 16293062
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Non-invasive beat-to-beat cardiac output monitoring by an improved method of transthoracic bioimpedance measurement.
    Fortin J; Habenbacher W; Heller A; Hacker A; Grüllenberger R; Innerhofer J; Passath H; Wagner Ch; Haitchi G; Flotzinger D; Pacher R; Wach P
    Comput Biol Med; 2006 Nov; 36(11):1185-203. PubMed ID: 16131462
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Autonomous monitoring with the personal computer-assessment].
    Wiesspeiner G
    Biomed Tech (Berl); 1990; 35 Suppl 2():177-8. PubMed ID: 2223980
    [No Abstract]   [Full Text] [Related]  

  • 17. Cardiac output and left atrial pressure monitoring by right ventricular pressure waveform analysis for potential implantable device application.
    Xu D; Olivier NB; Mukkamala R
    IEEE Trans Biomed Eng; 2009 Sep; 56(9):2335-9. PubMed ID: 19457736
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Determining arterial pressure, left atrial pressure and cardiac output from the left pneumatic drive line of the total artificial heart.
    Rosenberg G; Landis DL; Phillips WM; Stallsmith J; Pierce WS
    Trans Am Soc Artif Intern Organs; 1978; 24():341-4. PubMed ID: 362675
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Enhanced cardiac thermal dilution measurement of cardiac output, volumes, regurgitation, valve effective diameters, ventricular power and efficiency -- Feasibility analysis using digital simulation.
    Donovan FM; Taylor BC
    Technol Health Care; 2001; 9(5):377-86. PubMed ID: 11673669
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Continuous recording of cardiac output volume with the OptiQ system--experiences with clinical application].
    Soukup J; Henze D; Trawiel C; Trommler P; Hennig C; Radke J; Menzel M
    Anaesthesiol Reanim; 2000; 25(6):158-63. PubMed ID: 11194384
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.