These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Ceramic-on-ceramic THA associated with fewer dislocations and less muscle degeneration by preserving muscle progenitors. Hernigou P; Roussignol X; Delambre J; Poignard A; Flouzat-Lachaniette CH Clin Orthop Relat Res; 2015 Dec; 473(12):3762-9. PubMed ID: 26054482 [TBL] [Abstract][Full Text] [Related]
3. Polyethylene Liner and Femoral Head Exchange in Total Hip Arthroplasty: Factors Associated with Long-Term Success and Failure. Petis SM; Kubista B; Hartzler RU; Abdel MP; Berry DJ J Bone Joint Surg Am; 2019 Mar; 101(5):421-428. PubMed ID: 30845036 [TBL] [Abstract][Full Text] [Related]
4. Large Metal Heads and Highly Cross-Linked Polyethylene Provide Low Wear and Complications at 5-13 Years. Lachiewicz PF; O'Dell JA; Martell JM J Arthroplasty; 2018 Jul; 33(7):2187-2191. PubMed ID: 29588121 [TBL] [Abstract][Full Text] [Related]
6. Wear and Osteolysis of Highly Crosslinked Polyethylene at 10 to 14 Years: The Effect of Femoral Head Size. Lachiewicz PF; Soileau ES; Martell JM Clin Orthop Relat Res; 2016 Feb; 474(2):365-71. PubMed ID: 25903943 [TBL] [Abstract][Full Text] [Related]
7. Low early and late dislocation rates with 36- and 40-mm heads in patients at high risk for dislocation. Lachiewicz PF; Soileau ES Clin Orthop Relat Res; 2013 Feb; 471(2):439-43. PubMed ID: 22576929 [TBL] [Abstract][Full Text] [Related]
8. [Long-term results of alumina-on-alumina total hip arthroplasty]. Rousseau MA; Le Mouel S; Goutallier D; Van Driessche S Rev Chir Orthop Reparatrice Appar Mot; 2004 Dec; 90(8):741-8. PubMed ID: 15711492 [TBL] [Abstract][Full Text] [Related]
9. Postmortem study of femoral osteolysis associated with metal-on-metal articulation in total hip replacement: an analysis of nine cases. Huber M; Reinisch G; Zenz P; Zweymüller K; Lintner F J Bone Joint Surg Am; 2010 Jul; 92(8):1720-31. PubMed ID: 20660235 [TBL] [Abstract][Full Text] [Related]
11. Isolated acetabular revision with femoral stem retention after bipolar hip arthroplasty. Kaku N; Tabata T; Tagomori H; Tsumura H Arch Orthop Trauma Surg; 2017 Mar; 137(3):425-430. PubMed ID: 28150224 [TBL] [Abstract][Full Text] [Related]
12. A Minimum Ten Years of Follow-Up of Alumina Head on Delta Liner Total Hip Arthroplasty. Choy WS; Cha YH; Jeon CY; Lee KS; Kim HY J Arthroplasty; 2018 Feb; 33(2):470-476. PubMed ID: 28958658 [TBL] [Abstract][Full Text] [Related]
13. Revision Total Hip Arthroplasty with Retained Acetabular Component. Adelani MA; Mall NA; Nyazee H; Clohisy JC; Barrack RL; Nunley RM J Bone Joint Surg Am; 2014 Jun; 96(12):1015-1020. PubMed ID: 24951737 [TBL] [Abstract][Full Text] [Related]
14. Second-generation modular acetabular components provide fixation at 10 to 16 years. Lachiewicz PF; Soileau ES Clin Orthop Relat Res; 2012 Feb; 470(2):366-72. PubMed ID: 21691908 [TBL] [Abstract][Full Text] [Related]
15. A dual-mobility cup reduces risk of dislocation in isolated acetabular revisions. Civinini R; Carulli C; Matassi F; Nistri L; Innocenti M Clin Orthop Relat Res; 2012 Dec; 470(12):3542-8. PubMed ID: 22700131 [TBL] [Abstract][Full Text] [Related]
16. Complete acetabular cup revision versus isolated liner exchange for polyethylene wear and osteolysis without loosening in cementless total hip arthroplasty. Koh KH; Moon YW; Lim SJ; Lee HI; Shim JW; Park YS Arch Orthop Trauma Surg; 2011 Nov; 131(11):1591-600. PubMed ID: 21687959 [TBL] [Abstract][Full Text] [Related]
17. [Polyethylene liner replacement: behavior and morbidity in 68 cases]. Bidar R; Girard J; May O; Pinoit Y; Laffargue P; Migaud H Rev Chir Orthop Reparatrice Appar Mot; 2007 Sep; 93(5):461-8. PubMed ID: 17878837 [TBL] [Abstract][Full Text] [Related]
18. Low wear rates seen in THAs with highly crosslinked polyethylene at 9 to 14 years in patients younger than age 50 years. Garvin KL; White TC; Dusad A; Hartman CW; Martell J Clin Orthop Relat Res; 2015 Dec; 473(12):3829-35. PubMed ID: 26122983 [TBL] [Abstract][Full Text] [Related]
19. Ceramic-on-ceramic THA Implants in Patients Younger Than 20 Years. Hannouche D; Devriese F; Delambre J; Zadegan F; Tourabaly I; Sedel L; Chevret S; Nizard R Clin Orthop Relat Res; 2016 Feb; 474(2):520-7. PubMed ID: 26341897 [TBL] [Abstract][Full Text] [Related]
20. Long-Term Outcomes After Metal-on-Metal Total Hip Arthroplasty With a 28-mm Head: A 17- to 23-Year Follow-Up Study of a Previous Report. Moon JK; Kim Y; Hwang KT; Yang JH; Oh YH; Kim YH J Arthroplasty; 2018 Jul; 33(7):2165-2172. PubMed ID: 29656971 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]