These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 2254547)

  • 1. Evaluating severity of aortic stenosis: new validation of an old method.
    Dunn M; Hostetler M
    J Am Coll Cardiol; 1990 Dec; 16(7):1615-6. PubMed ID: 2254547
    [No Abstract]   [Full Text] [Related]  

  • 2. Ventricular stroke work loss: validation of a method of quantifying the severity of aortic stenosis and derivation of an orifice formula.
    Sprigings DC; Chambers JB; Cochrane T; Allen J; Jackson G
    J Am Coll Cardiol; 1990 Dec; 16(7):1608-14. PubMed ID: 2254546
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of valvular resistance, stroke work loss, and Gorlin valve area for quantification of aortic stenosis. An in vitro study in a pulsatile aortic flow model.
    Voelker W; Reul H; Nienhaus G; Stelzer T; Schmitz B; Steegers A; Karsch KR
    Circulation; 1995 Feb; 91(4):1196-204. PubMed ID: 7850959
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Left ventricular performance improves late after aortic valve replacement in patients with aortic stenosis and reduced ejection fraction.
    Robiolio PA; Rigolin VH; Hearne SE; Baker WA; Kisslo KB; Pierce CH; Bashore TM; Harrison JK
    Am J Cardiol; 1995 Sep; 76(8):612-5. PubMed ID: 7677090
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of valve resistance with effective orifice area regarding flow dependence.
    Blais C; Pibarot P; Dumesnil JG; Garcia D; Chen D; Durand LG
    Am J Cardiol; 2001 Jul; 88(1):45-52. PubMed ID: 11423057
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Role of Diastology in Transcatheter Aortic Valve Implantation.
    Sivasubramonian S; Gopalakrishnan A; Sasidharan B; Valaparambil A
    J Invasive Cardiol; 2018 Mar; 30(3):E23-E24. PubMed ID: 29493515
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Hemodynamic evaluation of heart valve prostheses paradigm shift for transcatheter valves?
    Walther T; Falk V
    J Am Coll Cardiol; 2009 May; 53(20):1892-3. PubMed ID: 19442890
    [No Abstract]   [Full Text] [Related]  

  • 8. Predictors of mortality and outcomes of therapy in low-flow severe aortic stenosis: a Placement of Aortic Transcatheter Valves (PARTNER) trial analysis.
    Herrmann HC; Pibarot P; Hueter I; Gertz ZM; Stewart WJ; Kapadia S; Tuzcu EM; Babaliaros V; Thourani V; Szeto WY; Bavaria JE; Kodali S; Hahn RT; Williams M; Miller DC; Douglas PS; Leon MB
    Circulation; 2013 Jun; 127(23):2316-26. PubMed ID: 23661722
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Transapical aortic valve implantation in Rouen: four years' experience with the Edwards transcatheter prosthesis.
    Litzler PY; Borz B; Smail H; Baste JM; Nafeh-Bizet C; Gay A; Tron C; Godin M; Caudron J; Hauville C; Dacher JN; Cribier A; Eltchaninoff H; Bessou JP
    Arch Cardiovasc Dis; 2012 Mar; 105(3):141-5. PubMed ID: 22520796
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Aortic valve in valve insertion: a note of caution and a case for possible optimism.
    Dean LS
    Catheter Cardiovasc Interv; 2010 Dec; 76(7):1007-8. PubMed ID: 21108376
    [No Abstract]   [Full Text] [Related]  

  • 11. Potential role of Reynolds number in resolving Doppler- and catheter-based transvalvular gradient discrepancies in aortic stenosis.
    Adams JC; Jiamsripong P; Belohlavek M; McMahon EM; Marupakula V; Heys J; Chaliki HP
    J Heart Valve Dis; 2011 Mar; 20(2):159-64. PubMed ID: 21560814
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A smart method of intraoperative explantation of an aortic bioprosthesis.
    Erdem CC; Park SJ
    J Card Surg; 2009; 24(5):515-7. PubMed ID: 19740286
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Value of ejection fraction/velocity ratio in the prognostic stratification of patients with asymptomatic aortic valve stenosis.
    Antonini-Canterin F; Di Nora C; Cervesato E; Zito C; Carerj S; Ravasel A; Cosei I; Popescu AC; Popescu BA
    Echocardiography; 2018 Dec; 35(12):1909-1914. PubMed ID: 30376590
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Contemporary application of cardiovascular hemodynamics: transcatheter aortic valve interventions.
    Jilaihawi H; Kar S; Doctor N; Fontana G; Makkar R
    Cardiol Clin; 2011 May; 29(2):211-22. PubMed ID: 21459244
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Aortic prosthesis-patient mismatch in patients with paradoxical low flow severe aortic stenosis: a dreadful combination.
    Boulogne C; Mohty D
    Arch Cardiovasc Dis; 2015 Jan; 108(1):1-4. PubMed ID: 25534885
    [No Abstract]   [Full Text] [Related]  

  • 16. Computational fluid dynamics simulation of transcatheter aortic valve degeneration.
    Dwyer HA; Matthews PB; Azadani A; Jaussaud N; Ge L; Guy TS; Tseng EE
    Interact Cardiovasc Thorac Surg; 2009 Aug; 9(2):301-8. PubMed ID: 19414489
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Early failures of Trifecta aortic bioprosthesis.
    Campisi S; Camilleri L; Innorta A; Azarnoush K
    J Thorac Cardiovasc Surg; 2014 Jul; 148(1):e133-4. PubMed ID: 24755333
    [No Abstract]   [Full Text] [Related]  

  • 18. Prospective Multicenter Evaluation of the Direct Flow Medical Transcatheter Aortic Valve System: 12-Month Outcomes of the Evaluation of the Direct Flow Medical Percutaneous Aortic Valve 18F System for the Treatment of Patients With Severe Aortic Stenosis (DISCOVER) Study.
    Lefèvre T; Colombo A; Tchétché D; Latib A; Klugmann S; Fajadet J; De Marco F; Maisano F; Bruschi G; Bijuklic K; Nava S; Weissman N; Low R; Thomas M; Young C; Redwood S; Mullen M; Yap J; Grube E; Nickenig G; Sinning JM; Hauptmann KE; Friedrich I; Lauterbach M; Schmoeckel M; Davidson C; Schofer J
    JACC Cardiovasc Interv; 2016 Jan; 9(1):68-75. PubMed ID: 26762913
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Thromboembolic events after aortic valve replacement in elderly patients with a Carpentier-Edwards Perimount pericardial bioprosthesis.
    Mistiaen W; Van Cauwelaert P; Muylaert P; Sys SU; Harrisson F; Bortier H
    J Thorac Cardiovasc Surg; 2004 Apr; 127(4):1166-70. PubMed ID: 15052218
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Assessment of Unicuspid Aortic Valve Stenosis Using Multimodality Imaging, X-ray Radiography and Raman Analysis.
    Chang HH; Cheng CL; Wang WC; Huang PJ; Lin SY
    Int Heart J; 2019 Mar; 60(2):482-488. PubMed ID: 30626768
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.