154 related articles for article (PubMed ID: 22547018)
1. Surgical outcome of liver transection by the crush-clamping technique combined with Harmonic FOCUS™.
Gotohda N; Konishi M; Takahashi S; Kinoshita T; Kato Y; Kinoshita T
World J Surg; 2012 Sep; 36(9):2156-60. PubMed ID: 22547018
[TBL] [Abstract][Full Text] [Related]
2. Usefulness of vessel-sealing devices combined with crush clamping method for hepatectomy: a retrospective cohort study.
Nanashima A; Abo T; Arai J; Takagi K; Matsumoto H; Takeshita H; Tsuchiya T; Nagayasu T
Int J Surg; 2013; 11(9):891-7. PubMed ID: 23954369
[TBL] [Abstract][Full Text] [Related]
3. Randomized clinical trial comparing two vessel-sealing devices with crush clamping during liver transection.
Ichida A; Hasegawa K; Takayama T; Kudo H; Sakamoto Y; Yamazaki S; Midorikawa Y; Higaki T; Matsuyama Y; Kokudo N
Br J Surg; 2016 Dec; 103(13):1795-1803. PubMed ID: 27682642
[TBL] [Abstract][Full Text] [Related]
4. The superficial precoagulation, sealing, and transection method: a "bloodless" and "ecofriendly" laparoscopic liver transection technique.
Itano O; Ikoma N; Takei H; Oshima G; Kitagawa Y
Surg Laparosc Endosc Percutan Tech; 2015 Feb; 25(1):e33-e36. PubMed ID: 24752166
[TBL] [Abstract][Full Text] [Related]
5. Radiofrequency vessel-sealing system versus the clamp-crushing technique in liver transection: results of a prospective randomized study on 100 consecutive patients.
Muratore A; Mellano A; Tarantino G; Marsanic P; De Simone M; Di Benedetto F
HPB (Oxford); 2014 Aug; 16(8):707-12. PubMed ID: 24467672
[TBL] [Abstract][Full Text] [Related]
6. Fusion technique for liver transection with Kelly-clysis and harmonic technology.
Jagannath P; Chhabra DG; Sutariya KR; Shah RC
World J Surg; 2010 Jan; 34(1):101-5. PubMed ID: 20020296
[TBL] [Abstract][Full Text] [Related]
7. Randomized clinical trial of BiClamp forceps versus clamp-crushing technique in open liver resection.
Chen JM; Geng W; Zhang S; Liu FB; Zhao HC; Zhao YJ; Wang GB; Xie SX; Geng XP
J Hepatobiliary Pancreat Sci; 2017 Mar; 24(3):137-142. PubMed ID: 28012285
[TBL] [Abstract][Full Text] [Related]
8. Usefulness of the combination procedure of crash clamping and vessel sealing for hepatic resection.
Nanashima A; Tobinaga S; Abo T; Nonaka T; Sawai T; Nagayasu T
J Surg Oncol; 2010 Aug; 102(2):179-83. PubMed ID: 20648591
[TBL] [Abstract][Full Text] [Related]
9. Randomized clinical trial of stapler versus clamp-crushing transection in elective liver resection.
Rahbari NN; Elbers H; Koch M; Vogler P; Striebel F; Bruckner T; Mehrabi A; Schemmer P; Büchler MW; Weitz J
Br J Surg; 2014 Feb; 101(3):200-7. PubMed ID: 24402888
[TBL] [Abstract][Full Text] [Related]
10. Impact of energy devices during liver parenchymal transection: a multicenter randomized controlled trial.
Gotohda N; Yamanaka T; Saiura A; Uesaka K; Hashimoto M; Konishi M; Shimada K
World J Surg; 2015 Jun; 39(6):1543-9. PubMed ID: 25637271
[TBL] [Abstract][Full Text] [Related]
11. Evaluation of a new energy device for parenchymal transection in laparoscopic liver resection.
Badawy A; Seo S; Toda R; Fuji H; Ishii T; Taura K; Yasuchika K; Kaido T; Uemoto S
Asian J Endosc Surg; 2018 May; 11(2):123-128. PubMed ID: 29027381
[TBL] [Abstract][Full Text] [Related]
12. Randomized comparison of ultrasonic vs clamp transection of the liver.
Takayama T; Makuuchi M; Kubota K; Harihara Y; Hui AM; Sano K; Ijichi M; Hasegawa K
Arch Surg; 2001 Aug; 136(8):922-8. PubMed ID: 11485528
[TBL] [Abstract][Full Text] [Related]
13. How should transection of the liver be performed?: a prospective randomized study in 100 consecutive patients: comparing four different transection strategies.
Lesurtel M; Selzner M; Petrowsky H; McCormack L; Clavien PA
Ann Surg; 2005 Dec; 242(6):814-22, discussion 822-3. PubMed ID: 16327491
[TBL] [Abstract][Full Text] [Related]
14. Modification of right hepatectomy results in improvement outcome: a retrospective comparative study.
Wong JS; Lee KF; Cheung YS; Chong CN; Wong J; Lai PB
HPB (Oxford); 2011 Jun; 13(6):431-7. PubMed ID: 21609377
[TBL] [Abstract][Full Text] [Related]
15. Hepatic parenchymal transection with vascular staplers: a comparative analysis with the crush-clamp technique.
Reddy SK; Barbas AS; Gan TJ; Hill SE; Roche AM; Clary BM
Am J Surg; 2008 Nov; 196(5):760-7. PubMed ID: 18639225
[TBL] [Abstract][Full Text] [Related]
16. Randomized clinical trial of stapler hepatectomy versus LigaSure™ transection in elective hepatic resection.
Fritzmann J; Kirchberg J; Sturm D; Ulrich AB; Knebel P; Mehrabi A; Büchler MW; Weitz J; Reissfelder C; Rahbari NN
Br J Surg; 2018 Aug; 105(9):1119-1127. PubMed ID: 30069876
[TBL] [Abstract][Full Text] [Related]
17. Hepatic resections by means of electrothermal bipolar vessel device (EBVS) LigaSure V: early experience.
Campagnacci R; De Sanctis A; Baldarelli M; Di Emiddio M; Organetti L; Nisi M; Lezoche G; Guerrieri M
Surg Endosc; 2007 Dec; 21(12):2280-4. PubMed ID: 17514383
[TBL] [Abstract][Full Text] [Related]
18. Techniques for liver parenchymal transection in liver resection.
Gurusamy KS; Pamecha V; Sharma D; Davidson BR
Cochrane Database Syst Rev; 2009 Jan; (1):CD006880. PubMed ID: 19160307
[TBL] [Abstract][Full Text] [Related]
19. Minor hepatic resection for hepatocellular carcinoma in cirrhotic patients: Kelly clamp crushing resection versus heat coagulative necrosis with bipolar radiofrequency device.
Sandonato L; Soresi M; Cipolla C; Bartolotta TV; Giannitrapani L; Antonucci M; Galia M; Latteri MA
Am Surg; 2011 Nov; 77(11):1490-5. PubMed ID: 22196663
[TBL] [Abstract][Full Text] [Related]
20. Laparoscopic liver resection using a monopolar soft-coagulation device to provide maximum intraoperative bleeding control for the treatment of hepatocellular carcinoma.
Miyazawa M; Aikawa M; Okada K; Watanabe Y; Okamoto K; Koyama I
Surg Endosc; 2018 Apr; 32(4):2157-2158. PubMed ID: 28916868
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]