113 related articles for article (PubMed ID: 22549030)
1. Mechanical failure after locking plate fixation of unstable intertrochanteric femur fractures.
Streubel PN; Moustoukas MJ; Obremskey WT
J Orthop Trauma; 2013 Jan; 27(1):22-8. PubMed ID: 22549030
[TBL] [Abstract][Full Text] [Related]
2. Early Mechanical Failures of the Synthes Variable Angle Locking Distal Femur Plate.
Tank JC; Schneider PS; Davis E; Galpin M; Prasarn ML; Choo AM; Munz JW; Achor TS; Kellam JF; Gary JL
J Orthop Trauma; 2016 Jan; 30(1):e7-e11. PubMed ID: 26849390
[TBL] [Abstract][Full Text] [Related]
3. Catastrophic failure after open reduction internal fixation of femoral neck fractures with a novel locking plate implant.
Berkes MB; Little MT; Lazaro LE; Cymerman RM; Helfet DL; Lorich DG
J Orthop Trauma; 2012 Oct; 26(10):e170-6. PubMed ID: 22430524
[TBL] [Abstract][Full Text] [Related]
4. Short-term follow-up of pertrochanteric fractures treated using the proximal femoral locking plate.
Johnson B; Stevenson J; Chamma R; Patel A; Rhee SJ; Lever C; Starks I; Roberts PJ
J Orthop Trauma; 2014 May; 28(5):283-7. PubMed ID: 24751607
[TBL] [Abstract][Full Text] [Related]
5. Comparison of the 95-degree angled blade plate and the locking condylar plate for the treatment of distal femoral fractures.
Vallier HA; Immler W
J Orthop Trauma; 2012 Jun; 26(6):327-32. PubMed ID: 22183200
[TBL] [Abstract][Full Text] [Related]
6. Risk factors for failure of locked plate fixation of distal femur fractures: an analysis of 335 cases.
Ricci WM; Streubel PN; Morshed S; Collinge CA; Nork SE; Gardner MJ
J Orthop Trauma; 2014 Feb; 28(2):83-9. PubMed ID: 23760176
[TBL] [Abstract][Full Text] [Related]
7. Unstable Proximal Femur Fractures Treated With Proximal Femoral Locking Plates: A Retrospective, Multicenter Study of 111 Cases.
Collinge CA; Hymes R; Archdeacon M; Streubel P; Obremskey W; Weber T; Watson JT; Lowenberg D;
J Orthop Trauma; 2016 Sep; 30(9):489-95. PubMed ID: 27144821
[TBL] [Abstract][Full Text] [Related]
8. Locking plates increase the strength of dynamic hip screws.
Jewell DP; Gheduzzi S; Mitchell MS; Miles AW
Injury; 2008 Feb; 39(2):209-12. PubMed ID: 17880976
[TBL] [Abstract][Full Text] [Related]
9. Treatment of Distal Femur Fractures With the DePuy-Synthes Variable Angle Locking Compression Plate.
McDonald TC; Lambert JJ; Hulick RM; Graves ML; Russell GV; Spitler CA; Bergin PF
J Orthop Trauma; 2019 Sep; 33(9):432-437. PubMed ID: 31259799
[TBL] [Abstract][Full Text] [Related]
10. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate.
Arora R; Lutz M; Hennerbichler A; Krappinger D; Espen D; Gabl M
J Orthop Trauma; 2007 May; 21(5):316-22. PubMed ID: 17485996
[TBL] [Abstract][Full Text] [Related]
11. Treatment of intertrochanteric fracture of the femur using sliding screw plate fixation.
Wolfgang GL; Bryant MH; O'Neill JP
Clin Orthop Relat Res; 1982 Mar; (163):148-58. PubMed ID: 7067245
[TBL] [Abstract][Full Text] [Related]
12. Complications following proximal femoral locking compression plating in unstable proximal femur fractures: medium-term follow-up.
Hodel S; Beeres FJP; Babst R; Link BC
Eur J Orthop Surg Traumatol; 2017 Dec; 27(8):1117-1124. PubMed ID: 28547675
[TBL] [Abstract][Full Text] [Related]
13. [Comparative study of intertrochanteric fractures treated with proximal femur locking compress plate in aged].
Wang Y; Yang YY; Yu ZH; Li CQ; Wu YS; Zheng XX
Zhongguo Gu Shang; 2011 May; 24(5):370-3. PubMed ID: 21688530
[TBL] [Abstract][Full Text] [Related]
14. Perioperative lateral trochanteric wall fractures: sliding hip screw versus percutaneous compression plate for intertrochanteric hip fractures.
Langford J; Pillai G; Ugliailoro AD; Yang E
J Orthop Trauma; 2011 Apr; 25(4):191-5. PubMed ID: 21399466
[TBL] [Abstract][Full Text] [Related]
15. Management of periprosthetic femur fractures with a first generation locking plate.
Fulkerson E; Tejwani N; Stuchin S; Egol K
Injury; 2007 Aug; 38(8):965-72. PubMed ID: 17561020
[TBL] [Abstract][Full Text] [Related]
16. Radiographic and functional results of osteosynthesis using the proximal femoral nail antirotation (PFNA) in the treatment of unstable intertrochanteric femoral fractures.
Sahin S; Ertürer E; Oztürk I; Toker S; Seçkin F; Akman S
Acta Orthop Traumatol Turc; 2010; 44(2):127-34. PubMed ID: 20676015
[TBL] [Abstract][Full Text] [Related]
17. Reoperation rate after internal fixation of intertrochanteric femur fractures with the percutaneous compression plate: what are the risk factors?
Schmidt-Rohlfing B; Heussen N; Knobe M; Pfeifer R; Kaneshige JR; Pape HC
J Orthop Trauma; 2013 Jun; 27(6):312-7. PubMed ID: 22955336
[TBL] [Abstract][Full Text] [Related]
18. Fixation failure of the LCP proximal femoral plate 4.5/5.0 in patients with missing posteromedial support in unstable per-, inter-, and subtrochanteric fractures of the proximal femur.
Wieser K; Babst R
Arch Orthop Trauma Surg; 2010 Oct; 130(10):1281-7. PubMed ID: 20191276
[TBL] [Abstract][Full Text] [Related]
19. Treatment of early cut-out of a lag screw using a trochanter supporting plate: 11 consecutive patients with unstable intertrochanteric fractures.
Lee PC; Yu SW; Hsieh PH; Chuang TY; Tai CL; Shih CH
Arch Orthop Trauma Surg; 2004 Mar; 124(2):119-22. PubMed ID: 14652777
[TBL] [Abstract][Full Text] [Related]
20. [Osteosynthesis for periprosthetic supracondylar fracture above a total knee arthroplasty using a locking compression plate].
Krbec M; Motycka J; Lunácek L; Dousa P
Acta Chir Orthop Traumatol Cech; 2009 Dec; 76(6):473-8. PubMed ID: 20067694
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]