These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 22549553)

  • 1. [Letter to the editor on the article by Pache G et al. Low-dose computed tomography for the detection of cocaine body packs: clinical evaluation and legal issues. Fortschr Röntgenstr 2012; 184: 122-129].
    Grimm JM; Wirth S; Reiser MF; Scherr M
    Rofo; 2012 May; 184(5):470; author reply 470. PubMed ID: 22549553
    [No Abstract]   [Full Text] [Related]  

  • 2. [Low-dose computed tomography for the detection of cocaine body packs: clinical evaluation and legal issues].
    Pache G; Einhaus D; Bulla S; Baumann T; Langer M; Blanke P
    Rofo; 2012 Feb; 184(2):122-9. PubMed ID: 22033846
    [TBL] [Abstract][Full Text] [Related]  

  • 3. "Drug mules" as a radiological challenge: sensitivity and specificity in identifying internal cocaine in body packers, body pushers and body stuffers by computed tomography, plain radiography and Lodox.
    Flach PM; Ross SG; Ampanozi G; Ebert L; Germerott T; Hatch GM; Thali MJ; Patak MA
    Eur J Radiol; 2012 Oct; 81(10):2518-26. PubMed ID: 22178312
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The detection of internal cocaine drug packs: a radiological challenge in the future?
    Liu Q; Liu W; Liang W
    Eur J Radiol; 2013 Sep; 82(9):1588. PubMed ID: 23523025
    [No Abstract]   [Full Text] [Related]  

  • 5. Response to "the detection of internal cocaine drug packs: a radiological challenge in the future?".
    Flach PM; Ross SG; Ebert LC; Thali MJ; Ampanozi G
    Eur J Radiol; 2013 Sep; 82(9):1588-90. PubMed ID: 23726125
    [No Abstract]   [Full Text] [Related]  

  • 6. [Atypical "body packing syndrome"--a case report].
    Brück S; Risse M; Schütz H; Weiler G; Verhoff MA
    Arch Kriminol; 2006; 218(1-2):35-43. PubMed ID: 16948259
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Detection of drug transport using X-ray techniques].
    Vogel H; Haller D; Laitenberger C; Heinemann A; Püschel K
    Arch Kriminol; 2006; 218(1-2):1-21. PubMed ID: 16948257
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Bodypacking.
    Buysschaert B; Weyers P
    Acta Clin Belg; 2010; 65(3):202-3. PubMed ID: 20669791
    [No Abstract]   [Full Text] [Related]  

  • 9. Response to Letter to the Editor: validation of a 6-hour observation period for cocaine body stuffers.
    Buchanan J; Moreira M; Heard K
    Am J Emerg Med; 2011 May; 29(4):471-2. PubMed ID: 21447435
    [No Abstract]   [Full Text] [Related]  

  • 10. Body packers on your examination table: How helpful are plain x-ray images? A definitive low-dose CT protocol as a diagnosis tool for body packers.
    Schulz B; Grossbach A; Gruber-Rouh T; Zangos S; Vogl TJ; Eichler K
    Clin Radiol; 2014 Dec; 69(12):e525-30. PubMed ID: 25300556
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The body packer syndrome--cocaine smuggling in the gastro-intestinal tract.
    Hartoko TJ; Demey HE; De Schepper AM; Beaucourt LE; Bossaert LL
    Klin Wochenschr; 1988 Nov; 66(22):1116-20. PubMed ID: 3236761
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Imaging of body packing: errors and medico-legal issues.
    Reginelli A; Russo A; Urraro F; Maresca D; Martiniello C; D'Andrea A; Brunese L; Pinto A
    Abdom Imaging; 2015 Oct; 40(7):2127-42. PubMed ID: 26063072
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Diagnostic imaging of "body packers"].
    Ichikawa K; Tajima N; Tajima H; Murakami R; Okada S; Hosaka J; Ito K; Yamamoto K; Kumazaki T; Masuno T; Yokota H; Makino T
    Nihon Igaku Hoshasen Gakkai Zasshi; 1997 Feb; 57(3):89-93. PubMed ID: 9077088
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Bodypacking].
    Markun S; Flach PM; Schweitzer W; Imbach S
    Praxis (Bern 1994); 2013 Jul; 102(15):891-901. PubMed ID: 23876685
    [No Abstract]   [Full Text] [Related]  

  • 15. Low-tube voltage 100 kVp MDCT in screening of cocaine body packing: image quality and radiation dose compared to 120 kVp MDCT.
    Aissa J; Rubbert C; Boos J; Schleich C; Thomas C; Kröpil P; Antoch G; Miese F
    Abdom Imaging; 2015 Oct; 40(7):2152-8. PubMed ID: 26048697
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Detection of intestinal drug containers: clinical and radiological features.
    Zeina AR; Meisel SR; Abu-Mouch S; Ashkar J; Alfici R; Mahamid A
    Isr Med Assoc J; 2012 Oct; 14(10):649-51. PubMed ID: 23193791
    [No Abstract]   [Full Text] [Related]  

  • 17. Systematic Evaluation of Radiation Dose Reduction in CT Studies of Body Packers: Accuracy Down to Submillisievert Levels.
    Laberke PJ; Blum S; Waelti S; Fornaro J; Hausmann R; Alkadhi H; Leschka S
    AJR Am J Roentgenol; 2016 Apr; 206(4):740-6. PubMed ID: 26866340
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Letter concerning the article: Initial results of lumbar dual-energy roentgen absorptiometry in comparison to dual-energy quantitative computerized tomography. by Link, J.M., M. Zwaan, H.D.Weiss, K.J. Borgis, B. Bätge in: Fortschr. Röntgenstr. 158 (1993) 475-478].
    Schneider P; Lassmann M; Börner W
    Rofo; 1994 Feb; 160(2):186-8. PubMed ID: 8312522
    [No Abstract]   [Full Text] [Related]  

  • 19. Unusual finding on bronchoscopy: trauma patient identified as a body stuffer.
    Chang C; Grush A; McClintock DE; Nahid P; Tang JF
    J Clin Anesth; 2006 Dec; 18(8):628-30. PubMed ID: 17175436
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Abdominal radiography in suspected 'body packers'.
    Horrocks AW
    Clin Radiol; 1992 May; 45(5):322-5. PubMed ID: 1516342
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.