These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
149 related articles for article (PubMed ID: 22552156)
1. Improved prediction of disturbed flow via hemodynamically-inspired geometric variables. Bijari PB; Antiga L; Gallo D; Wasserman BA; Steinman DA J Biomech; 2012 Jun; 45(9):1632-7. PubMed ID: 22552156 [TBL] [Abstract][Full Text] [Related]
2. Effect of carotid artery geometry on the magnitude and distribution of wall shear stress gradients. Wells DR; Archie JP; Kleinstreuer C J Vasc Surg; 1996 Apr; 23(4):667-78. PubMed ID: 8627904 [TBL] [Abstract][Full Text] [Related]
3. An insight into the mechanistic role of the common carotid artery on the hemodynamics at the carotid bifurcation. Gallo D; Steinman DA; Morbiducci U Ann Biomed Eng; 2015 Jan; 43(1):68-81. PubMed ID: 25234131 [TBL] [Abstract][Full Text] [Related]
4. Geometry of the carotid bifurcation predicts its exposure to disturbed flow. Lee SW; Antiga L; Spence JD; Steinman DA Stroke; 2008 Aug; 39(8):2341-7. PubMed ID: 18556585 [TBL] [Abstract][Full Text] [Related]
5. Computational analysis of effects of external carotid artery flow and occlusion on adverse carotid bifurcation hemodynamics. Hyun S; Kleinstreuer C; Archie JP J Vasc Surg; 2003 Jun; 37(6):1248-54. PubMed ID: 12764272 [TBL] [Abstract][Full Text] [Related]
6. Hemodynamics of human carotid artery bifurcations: computational studies with models reconstructed from magnetic resonance imaging of normal subjects. Milner JS; Moore JA; Rutt BK; Steinman DA J Vasc Surg; 1998 Jul; 28(1):143-56. PubMed ID: 9685141 [TBL] [Abstract][Full Text] [Related]
7. Computer simulation of local blood flow and vessel mechanics in a compliant carotid artery bifurcation model. Perktold K; Rappitsch G J Biomech; 1995 Jul; 28(7):845-56. PubMed ID: 7657682 [TBL] [Abstract][Full Text] [Related]
8. Hemodynamics and wall mechanics in human carotid bifurcation and its consequences for atherogenesis: investigation of inter-individual variation. Younis HF; Kaazempur-Mofrad MR; Chan RC; Isasi AG; Hinton DP; Chau AH; Kim LA; Kamm RD Biomech Model Mechanobiol; 2004 Sep; 3(1):17-32. PubMed ID: 15300454 [TBL] [Abstract][Full Text] [Related]
9. Parametric geometry exploration of the human carotid artery bifurcation. Bressloff NW J Biomech; 2007; 40(11):2483-91. PubMed ID: 17196211 [TBL] [Abstract][Full Text] [Related]
10. Preliminary study of hemodynamics in human carotid bifurcation by computational fluid dynamics combined with magnetic resonance angiography. Xue Y; Gao P; Lin Y; Dai C Acta Radiol; 2007 Sep; 48(7):788-97. PubMed ID: 17729012 [TBL] [Abstract][Full Text] [Related]
11. Analysis of the flow in stenosed carotid artery bifurcation models--hydrogen-bubble visualisation. Palmen DE; van de Vosse FN; Janssen JD; van Dongen ME J Biomech; 1994 May; 27(5):581-90. PubMed ID: 8027092 [TBL] [Abstract][Full Text] [Related]
12. Flow and stress characteristics in rigid walled and compliant carotid artery bifurcation models. Perktold K; Thurner E; Kenner T Med Biol Eng Comput; 1994 Jan; 32(1):19-26. PubMed ID: 8182957 [TBL] [Abstract][Full Text] [Related]
13. Choice of in vivo versus idealized velocity boundary conditions influences physiologically relevant flow patterns in a subject-specific simulation of flow in the human carotid bifurcation. Wake AK; Oshinski JN; Tannenbaum AR; Giddens DP J Biomech Eng; 2009 Feb; 131(2):021013. PubMed ID: 19102572 [TBL] [Abstract][Full Text] [Related]
14. Effect of asymmetry on the flow behavior in an idealized arterial bifurcation. Nagargoje M; Gupta R Comput Methods Biomech Biomed Engin; 2020 May; 23(6):232-247. PubMed ID: 31931612 [TBL] [Abstract][Full Text] [Related]
15. Effect of common carotid artery inlet length on normal carotid bifurcation hemodynamics. Hoi Y; Wasserman BA; Lakatta EG; Steinman DA J Biomech Eng; 2010 Dec; 132(12):121008. PubMed ID: 21142322 [TBL] [Abstract][Full Text] [Related]
16. Flow patterns and wall shear stress distribution in human internal carotid arteries: the geometric effect on the risk for stenoses. Zhang C; Xie S; Li S; Pu F; Deng X; Fan Y; Li D J Biomech; 2012 Jan; 45(1):83-9. PubMed ID: 22079384 [TBL] [Abstract][Full Text] [Related]
17. Carotid geometry effects on blood flow and on risk for vascular disease. Nguyen KT; Clark CD; Chancellor TJ; Papavassiliou DV J Biomech; 2008; 41(1):11-9. PubMed ID: 17919645 [TBL] [Abstract][Full Text] [Related]
18. Quantitative analysis of bulk flow in image-based hemodynamic models of the carotid bifurcation: the influence of outflow conditions as test case. Morbiducci U; Gallo D; Ponzini R; Massai D; Antiga L; Montevecchi FM; Redaelli A Ann Biomed Eng; 2010 Dec; 38(12):3688-705. PubMed ID: 20589532 [TBL] [Abstract][Full Text] [Related]
19. The influence of flow, vessel diameter, and non-newtonian blood viscosity on the wall shear stress in a carotid bifurcation model for unsteady flow. Box FM; van der Geest RJ; Rutten MC; Reiber JH Invest Radiol; 2005 May; 40(5):277-94. PubMed ID: 15829825 [TBL] [Abstract][Full Text] [Related]
20. Preliminary study of hemodynamic distribution in patient-specific stenotic carotid bifurcation by image-based computational fluid dynamics. Xue YJ; Gao PY; Duan Q; Lin Y; Dai CB Acta Radiol; 2008 Jun; 49(5):558-65. PubMed ID: 18568543 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]