These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

137 related articles for article (PubMed ID: 22553824)

  • 1. Feasibility of fast MR-thermometry during cardiac radiofrequency ablation.
    de Senneville BD; Roujol S; Jaïs P; Moonen CT; Herigault G; Quesson B
    NMR Biomed; 2012 Apr; 25(4):556-62. PubMed ID: 22553824
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Improved cardiac magnetic resonance thermometry and dosimetry for monitoring lesion formation during catheter ablation.
    Ozenne V; Toupin S; Bour P; de Senneville BD; Lepetit-Coiffé M; Boissenin M; Benois-Pineau J; Hansen MS; Inati SJ; Govari A; Jaïs P; Quesson B
    Magn Reson Med; 2017 Feb; 77(2):673-683. PubMed ID: 26899165
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Feasibility of real-time MR thermal dose mapping for predicting radiofrequency ablation outcome in the myocardium in vivo.
    Toupin S; Bour P; Lepetit-Coiffé M; Ozenne V; Denis de Senneville B; Schneider R; Vaussy A; Chaumeil A; Cochet H; Sacher F; Jaïs P; Quesson B
    J Cardiovasc Magn Reson; 2017 Jan; 19(1):14. PubMed ID: 28143574
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Assessment of left ventricle magnetic resonance temperature stability in patients in the presence of arrhythmias.
    Ozenne V; Bour P; de Senneville BD; Toupin S; Vaussy A; Lepetit-Coiffé M; Jaïs P; Cochet H; Quesson B
    NMR Biomed; 2019 Nov; 32(11):e4160. PubMed ID: 31397942
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Validation of fast MR thermometry at 1.5 T with gradient-echo echo planar imaging sequences: phantom and clinical feasibility studies.
    Cernicanu A; Lepetit-Coiffe M; Roland J; Becker CD; Terraz S
    NMR Biomed; 2008 Oct; 21(8):849-58. PubMed ID: 18574794
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reference-free PRFS MR-thermometry using near-harmonic 2-D reconstruction of the background phase.
    Salomir R; Viallon M; Kickhefel A; Roland J; Morel DR; Petrusca L; Auboiroux V; Goget T; Terraz S; Becker CD; Gross P
    IEEE Trans Med Imaging; 2012 Feb; 31(2):287-301. PubMed ID: 21937345
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Observation and correction of transient cavitation-induced PRFS thermometry artifacts during radiofrequency ablation, using simultaneous ultrasound/MR imaging.
    Viallon M; Terraz S; Roland J; Dumont E; Becker CD; Salomir R
    Med Phys; 2010 Apr; 37(4):1491-506. PubMed ID: 20443470
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Epicardial electroanatomical mapping, radiofrequency ablation, and lesion imaging in the porcine left ventricle under real-time magnetic resonance imaging guidance-an in vivo feasibility study.
    Mukherjee RK; Roujol S; Chubb H; Harrison J; Williams S; Whitaker J; O'Neill L; Silberbauer J; Neji R; Schneider R; Pohl T; Lloyd T; O'Neill M; Razavi R
    Europace; 2018 Sep; 20(FI2):f254-f262. PubMed ID: 29294008
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Real-time volumetric MRI thermometry of focused ultrasound ablation in vivo: a feasibility study in pig liver and kidney.
    Quesson B; Laurent C; Maclair G; de Senneville BD; Mougenot C; Ries M; Carteret T; Rullier A; Moonen CT
    NMR Biomed; 2011 Feb; 24(2):145-53. PubMed ID: 21344531
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Initial feasibility testing of limited field of view magnetic resonance thermometry using a local cardiac radiofrequency coil.
    Volland NA; Kholmovski EG; Parker DL; Hadley JR
    Magn Reson Med; 2013 Oct; 70(4):994-1004. PubMed ID: 23165722
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Radiofrequency ablation of small liver malignancies under magnetic resonance guidance: progress in targeting and preliminary observations with temperature monitoring.
    Terraz S; Cernicanu A; Lepetit-Coiffé M; Viallon M; Salomir R; Mentha G; Becker CD
    Eur Radiol; 2010 Apr; 20(4):886-97. PubMed ID: 19760231
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Real-time method for motion-compensated MR thermometry and MRgHIFU treatment in abdominal organs.
    Celicanin Z; Auboiroux V; Bieri O; Petrusca L; Santini F; Viallon M; Scheffler K; Salomir R
    Magn Reson Med; 2014 Oct; 72(4):1087-95. PubMed ID: 24243500
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Real time monitoring of radiofrequency ablation based on MR thermometry and thermal dose in the pig liver in vivo.
    Seror O; Lepetit-Coiffé M; Le Bail B; de Senneville BD; Trillaud H; Moonen C; Quesson B
    Eur Radiol; 2008 Feb; 18(2):408-16. PubMed ID: 17899103
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Motion-compensated real-time MR thermometry augmented by tracking coils.
    Wang P; Unal O
    J Magn Reson Imaging; 2015 Mar; 41(3):851-7. PubMed ID: 24478147
    [TBL] [Abstract][Full Text] [Related]  

  • 15. 3D motion strategy for online volumetric thermometry using simultaneous multi-slice EPI at 1.5T: an evaluation study.
    Ozenne V; Bour P; Denis de Senneville B; Quesson B
    Int J Hyperthermia; 2023; 40(1):2194595. PubMed ID: 37080550
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Continuous cardiac thermometry via simultaneous catheter tracking and undersampled radial golden angle acquisition for radiofrequency ablation monitoring.
    Yon M; Delcey M; Bour P; Grissom W; Quesson B; Ozenne V
    Sci Rep; 2022 Mar; 12(1):4006. PubMed ID: 35256627
    [TBL] [Abstract][Full Text] [Related]  

  • 17. RF field visualization of RF ablation at the Larmor frequency.
    Shultz K; Stang P; Kerr A; Pauly J; Scott G
    IEEE Trans Med Imaging; 2012 Apr; 31(4):938-47. PubMed ID: 21775256
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Threshold-based prediction of the coagulation zone in sequential temperature mapping in MR-guided radiofrequency ablation of liver tumours.
    Rempp H; Hoffmann R; Roland J; Buck A; Kickhefel A; Claussen CD; Pereira PL; Schick F; Clasen S
    Eur Radiol; 2012 May; 22(5):1091-100. PubMed ID: 22105843
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Real-time monitoring of radiofrequency ablation of liver tumors using thermal-dose calculation by MR temperature imaging: initial results in nine patients, including follow-up.
    Lepetit-Coiffé M; Laumonier H; Seror O; Quesson B; Sesay MB; Moonen CT; Grenier N; Trillaud H
    Eur Radiol; 2010 Jan; 20(1):193-201. PubMed ID: 19657650
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Noninvasive assessment of tissue heating during cardiac radiofrequency ablation using MRI thermography.
    Kolandaivelu A; Zviman MM; Castro V; Lardo AC; Berger RD; Halperin HR
    Circ Arrhythm Electrophysiol; 2010 Oct; 3(5):521-9. PubMed ID: 20657028
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.