372 related articles for article (PubMed ID: 22559636)
1. Geometric distortion and shimming considerations in a rotating MR-linac design due to the influence of low-level external magnetic fields. Wachowicz K; Tadic T; Fallone BG Med Phys; 2012 May; 39(5):2659-68. PubMed ID: 22559636 [TBL] [Abstract][Full Text] [Related]
2. Implications of tissue magnetic susceptibility-related distortion on the rotating magnet in an MR-linac design. Wachowicz K; Stanescu T; Thomas SD; Fallone BG Med Phys; 2010 Apr; 37(4):1714-21. PubMed ID: 20443492 [TBL] [Abstract][Full Text] [Related]
3. Impact of the MLC on the MRI field distortion of a prototype MRI-linac. Kolling S; Oborn B; Keall P Med Phys; 2013 Dec; 40(12):121705. PubMed ID: 24320491 [TBL] [Abstract][Full Text] [Related]
4. Combined passive and active shimming for in vivo MR spectroscopy at high magnetic fields. Juchem C; Muller-Bierl B; Schick F; Logothetis NK; Pfeuffer J J Magn Reson; 2006 Dec; 183(2):278-89. PubMed ID: 17011219 [TBL] [Abstract][Full Text] [Related]
5. Characterization of tissue magnetic susceptibility-induced distortions for MRIgRT. Stanescu T; Wachowicz K; Jaffray DA Med Phys; 2012 Dec; 39(12):7185-93. PubMed ID: 23231269 [TBL] [Abstract][Full Text] [Related]
6. Investigation of the 4D composite MR image distortion field associated with tumor motion for MR-guided radiotherapy. Stanescu T; Jaffray D Med Phys; 2016 Mar; 43(3):1550-62. PubMed ID: 26936738 [TBL] [Abstract][Full Text] [Related]
7. From static to dynamic 1.5T MRI-linac prototype: impact of gantry position related magnetic field variation on image fidelity. Crijns S; Raaymakers B Phys Med Biol; 2014 Jul; 59(13):3241-7. PubMed ID: 24874027 [TBL] [Abstract][Full Text] [Related]
8. Magnetic decoupling of the linac in a low field biplanar linac-MR system. St Aubin J; Steciw S; Fallone BG Med Phys; 2010 Sep; 37(9):4755-61. PubMed ID: 20964194 [TBL] [Abstract][Full Text] [Related]
9. The effects of magnetic field distortion on the accuracy of passive device localization frames in MR imaging. Cepek J; Chronik BA; Fenster A Med Phys; 2014 May; 41(5):052301. PubMed ID: 24784394 [TBL] [Abstract][Full Text] [Related]
11. On the passive shimming of a 7 T whole-body MRI superconducting magnet: Implementation with minimized ferromagnetic materials usage and operable magnetic force control. Wang W; Wang Y; Wang H; Cheng J; Qu H; Wang C; Niu C; Liu F Med Phys; 2023 Oct; 50(10):6514-6524. PubMed ID: 37287208 [TBL] [Abstract][Full Text] [Related]
12. Magnetic shielding investigation for a 6 MV in-line linac within the parallel configuration of a linac-MR system. Santos DM; St Aubin J; Fallone BG; Steciw S Med Phys; 2012 Feb; 39(2):788-97. PubMed ID: 22320788 [TBL] [Abstract][Full Text] [Related]
13. Skin dose in longitudinal and transverse linac-MRIs using Monte Carlo and realistic 3D MRI field models. Keyvanloo A; Burke B; Warkentin B; Tadic T; Rathee S; Kirkby C; Santos DM; Fallone BG Med Phys; 2012 Oct; 39(10):6509-21. PubMed ID: 23039685 [TBL] [Abstract][Full Text] [Related]
14. Modeling real shim fields for very high degree (and order) B Chang P; Nassirpour S; Henning A Magn Reson Med; 2018 Jan; 79(1):529-540. PubMed ID: 28321902 [TBL] [Abstract][Full Text] [Related]
15. Correcting geometric image distortions in slice-based 4D-MRI on the MR-linac. Keesman R; van de Lindt TN; Juan-Cruz C; van den Wollenberg W; van der Bijl E; Nowee ME; Sonke JJ; van der Heide UA; Fast MF Med Phys; 2019 Jul; 46(7):3044-3054. PubMed ID: 31111494 [TBL] [Abstract][Full Text] [Related]
16. Hybrid active and passive local shimming (HAPLS) for two-region MRI. Ren ZH; Stockmann J; Dewdney A; Lee RF Magn Reson Med; 2023 Apr; 89(4):1660-1673. PubMed ID: 36441786 [TBL] [Abstract][Full Text] [Related]
17. MRI B Jackson S; Glitzner M; Tijssen RHN; Raaymakers BW Phys Med Biol; 2019 Jun; 64(12):12NT01. PubMed ID: 31108467 [TBL] [Abstract][Full Text] [Related]
18. A novel electron gun for inline MRI-linac configurations. Constantin DE; Holloway L; Keall PJ; Fahrig R Med Phys; 2014 Feb; 41(2):022301. PubMed ID: 24506639 [TBL] [Abstract][Full Text] [Related]
19. Proton beam behavior in a parallel configured MRI-proton therapy hybrid: Effects of time-varying gradient magnetic fields. Santos DM; Wachowicz K; Burke B; Fallone BG Med Phys; 2019 Feb; 46(2):822-838. PubMed ID: 30488968 [TBL] [Abstract][Full Text] [Related]
20. Dosimetric Impact of MRI Distortions: A Study on Head and Neck Cancers. Adjeiwaah M; Bylund M; Lundman JA; Söderström K; Zackrisson B; Jonsson JH; Garpebring A; Nyholm T Int J Radiat Oncol Biol Phys; 2019 Mar; 103(4):994-1003. PubMed ID: 30496879 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]