These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

372 related articles for article (PubMed ID: 22559636)

  • 1. Geometric distortion and shimming considerations in a rotating MR-linac design due to the influence of low-level external magnetic fields.
    Wachowicz K; Tadic T; Fallone BG
    Med Phys; 2012 May; 39(5):2659-68. PubMed ID: 22559636
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Implications of tissue magnetic susceptibility-related distortion on the rotating magnet in an MR-linac design.
    Wachowicz K; Stanescu T; Thomas SD; Fallone BG
    Med Phys; 2010 Apr; 37(4):1714-21. PubMed ID: 20443492
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Impact of the MLC on the MRI field distortion of a prototype MRI-linac.
    Kolling S; Oborn B; Keall P
    Med Phys; 2013 Dec; 40(12):121705. PubMed ID: 24320491
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Combined passive and active shimming for in vivo MR spectroscopy at high magnetic fields.
    Juchem C; Muller-Bierl B; Schick F; Logothetis NK; Pfeuffer J
    J Magn Reson; 2006 Dec; 183(2):278-89. PubMed ID: 17011219
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Characterization of tissue magnetic susceptibility-induced distortions for MRIgRT.
    Stanescu T; Wachowicz K; Jaffray DA
    Med Phys; 2012 Dec; 39(12):7185-93. PubMed ID: 23231269
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Investigation of the 4D composite MR image distortion field associated with tumor motion for MR-guided radiotherapy.
    Stanescu T; Jaffray D
    Med Phys; 2016 Mar; 43(3):1550-62. PubMed ID: 26936738
    [TBL] [Abstract][Full Text] [Related]  

  • 7. From static to dynamic 1.5T MRI-linac prototype: impact of gantry position related magnetic field variation on image fidelity.
    Crijns S; Raaymakers B
    Phys Med Biol; 2014 Jul; 59(13):3241-7. PubMed ID: 24874027
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Magnetic decoupling of the linac in a low field biplanar linac-MR system.
    St Aubin J; Steciw S; Fallone BG
    Med Phys; 2010 Sep; 37(9):4755-61. PubMed ID: 20964194
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The effects of magnetic field distortion on the accuracy of passive device localization frames in MR imaging.
    Cepek J; Chronik BA; Fenster A
    Med Phys; 2014 May; 41(5):052301. PubMed ID: 24784394
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Proton beam deflection in MRI fields: Implications for MRI-guided proton therapy.
    Oborn BM; Dowdell S; Metcalfe PE; Crozier S; Mohan R; Keall PJ
    Med Phys; 2015 May; 42(5):2113-24. PubMed ID: 25979006
    [TBL] [Abstract][Full Text] [Related]  

  • 11. On the passive shimming of a 7 T whole-body MRI superconducting magnet: Implementation with minimized ferromagnetic materials usage and operable magnetic force control.
    Wang W; Wang Y; Wang H; Cheng J; Qu H; Wang C; Niu C; Liu F
    Med Phys; 2023 Oct; 50(10):6514-6524. PubMed ID: 37287208
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Magnetic shielding investigation for a 6 MV in-line linac within the parallel configuration of a linac-MR system.
    Santos DM; St Aubin J; Fallone BG; Steciw S
    Med Phys; 2012 Feb; 39(2):788-97. PubMed ID: 22320788
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Skin dose in longitudinal and transverse linac-MRIs using Monte Carlo and realistic 3D MRI field models.
    Keyvanloo A; Burke B; Warkentin B; Tadic T; Rathee S; Kirkby C; Santos DM; Fallone BG
    Med Phys; 2012 Oct; 39(10):6509-21. PubMed ID: 23039685
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Modeling real shim fields for very high degree (and order) B
    Chang P; Nassirpour S; Henning A
    Magn Reson Med; 2018 Jan; 79(1):529-540. PubMed ID: 28321902
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Correcting geometric image distortions in slice-based 4D-MRI on the MR-linac.
    Keesman R; van de Lindt TN; Juan-Cruz C; van den Wollenberg W; van der Bijl E; Nowee ME; Sonke JJ; van der Heide UA; Fast MF
    Med Phys; 2019 Jul; 46(7):3044-3054. PubMed ID: 31111494
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Hybrid active and passive local shimming (HAPLS) for two-region MRI.
    Ren ZH; Stockmann J; Dewdney A; Lee RF
    Magn Reson Med; 2023 Apr; 89(4):1660-1673. PubMed ID: 36441786
    [TBL] [Abstract][Full Text] [Related]  

  • 17. MRI B
    Jackson S; Glitzner M; Tijssen RHN; Raaymakers BW
    Phys Med Biol; 2019 Jun; 64(12):12NT01. PubMed ID: 31108467
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A novel electron gun for inline MRI-linac configurations.
    Constantin DE; Holloway L; Keall PJ; Fahrig R
    Med Phys; 2014 Feb; 41(2):022301. PubMed ID: 24506639
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Proton beam behavior in a parallel configured MRI-proton therapy hybrid: Effects of time-varying gradient magnetic fields.
    Santos DM; Wachowicz K; Burke B; Fallone BG
    Med Phys; 2019 Feb; 46(2):822-838. PubMed ID: 30488968
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Dosimetric Impact of MRI Distortions: A Study on Head and Neck Cancers.
    Adjeiwaah M; Bylund M; Lundman JA; Söderström K; Zackrisson B; Jonsson JH; Garpebring A; Nyholm T
    Int J Radiat Oncol Biol Phys; 2019 Mar; 103(4):994-1003. PubMed ID: 30496879
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 19.