134 related articles for article (PubMed ID: 22559656)
1. Development and testing of an improved dosimetry system using a backscatter shielded electronic portal imaging device.
King BW; Morf D; Greer PB
Med Phys; 2012 May; 39(5):2839-47. PubMed ID: 22559656
[TBL] [Abstract][Full Text] [Related]
2. Dose-to-water conversion for the backscatter-shielded EPID: a frame-based method to correct for EPID energy response to MLC transmitted radiation.
Zwan BJ; King BW; O'Connor DJ; Greer PB
Med Phys; 2014 Aug; 41(8):081716. PubMed ID: 25086526
[TBL] [Abstract][Full Text] [Related]
3. Feasibility study of a dual detector configuration concept for simultaneous megavoltage imaging and dose verification in radiotherapy.
Deshpande S; McNamara AL; Holloway L; Metcalfe P; Vial P
Med Phys; 2015 Apr; 42(4):1753-64. PubMed ID: 25832065
[TBL] [Abstract][Full Text] [Related]
4. EPID-based dosimetry to verify IMRT planar dose distribution for the aS1200 EPID and FFF beams.
Miri N; Keller P; Zwan BJ; Greer P
J Appl Clin Med Phys; 2016 Nov; 17(6):292-304. PubMed ID: 27929502
[TBL] [Abstract][Full Text] [Related]
5. Measurement and modeling of the effect of support arm backscatter on dosimetry with a varian EPID.
Rowshanfarzad P; McCurdy BM; Sabet M; Lee C; O'Connor DJ; Greer PB
Med Phys; 2010 May; 37(5):2269-78. PubMed ID: 20527561
[TBL] [Abstract][Full Text] [Related]
6. A simple model for transit dosimetry based on a water equivalent EPID.
Deshpande S; Blake SJ; Xing A; Metcalfe PE; Holloway LC; Vial P
Med Phys; 2018 Mar; 45(3):1266-1275. PubMed ID: 29314080
[TBL] [Abstract][Full Text] [Related]
7. A portal dosimetry dose prediction method based on collapsed cone algorithm using the clinical beam model.
Martínez Ortega J; Gómez González N; Castro Tejero P; Pinto Monedero M; Tolani NB; Núñez Martín L; Sánchez Montero R
Med Phys; 2017 Jan; 44(1):333-341. PubMed ID: 28102946
[TBL] [Abstract][Full Text] [Related]
8. Characterization of a novel EPID designed for simultaneous imaging and dose verification in radiotherapy.
Blake SJ; McNamara AL; Deshpande S; Holloway L; Greer PB; Kuncic Z; Vial P
Med Phys; 2013 Sep; 40(9):091902. PubMed ID: 24007153
[TBL] [Abstract][Full Text] [Related]
9. Dosimetric properties of an amorphous silicon EPID for verification of modulated electron radiotherapy.
Chatelain C; Vetterli D; Henzen D; Favre P; Morf D; Scheib S; Fix MK; Manser P
Med Phys; 2013 Jun; 40(6):061710. PubMed ID: 23718589
[TBL] [Abstract][Full Text] [Related]
10. Clinical experience with EPID dosimetry for prostate IMRT pre-treatment dose verification.
McDermott LN; Wendling M; van Asselen B; Stroom J; Sonke JJ; van Herk M; Mijnheer BJ
Med Phys; 2006 Oct; 33(10):3921-30. PubMed ID: 17089854
[TBL] [Abstract][Full Text] [Related]
11. A method for removing arm backscatter from EPID images.
King BW; Greer PB
Med Phys; 2013 Jul; 40(7):071703. PubMed ID: 23822407
[TBL] [Abstract][Full Text] [Related]
12. Improvement of Varian a-Si EPID dosimetry measurements using a lead-shielded support-arm.
Rowshanfarzad P; Sabet M; O'Connor DJ; Greer PB
Med Dosim; 2012; 37(2):145-51. PubMed ID: 21925865
[TBL] [Abstract][Full Text] [Related]
13. Initial evaluation of a commercial EPID modified to a novel direct-detection configuration for radiotherapy dosimetry.
Vial P; Greer PB; Oliver L; Baldock C
Med Phys; 2008 Oct; 35(10):4362-74. PubMed ID: 18975682
[TBL] [Abstract][Full Text] [Related]
14. Implementation of EPID transit dosimetry based on a through-air dosimetry algorithm.
Berry SL; Sheu RD; Polvorosa CS; Wuu CS
Med Phys; 2012 Jan; 39(1):87-98. PubMed ID: 22225278
[TBL] [Abstract][Full Text] [Related]
15. Fast transit portal dosimetry using density-scaled layer modeling of aSi-based electronic portal imaging device and Monte Carlo method.
Jung JW; Kim JO; Yeo IJ; Cho YB; Kim SM; DiBiase S
Med Phys; 2012 Dec; 39(12):7593-602. PubMed ID: 23231307
[TBL] [Abstract][Full Text] [Related]
16. Experimental investigation of the response of an a-Si EPID to an unflattened photon beam from an Elekta Precise linear accelerator.
Tyner E; McClean B; McCavana P; af Wetterstedt S
Med Phys; 2009 Apr; 36(4):1318-29. PubMed ID: 19472639
[TBL] [Abstract][Full Text] [Related]
17. A field size specific backscatter correction algorithm for accurate EPID dosimetry.
Berry SL; Polvorosa CS; Wuu CS
Med Phys; 2010 Jun; 37(6):2425-34. PubMed ID: 20632552
[TBL] [Abstract][Full Text] [Related]
18. Accurate two-dimensional IMRT verification using a back-projection EPID dosimetry method.
Wendling M; Louwe RJ; McDermott LN; Sonke JJ; van Herk M; Mijnheer BJ
Med Phys; 2006 Feb; 33(2):259-73. PubMed ID: 16532930
[TBL] [Abstract][Full Text] [Related]
19. Characterization of optical transport effects on EPID dosimetry using Geant4.
Blake SJ; Vial P; Holloway L; Greer PB; McNamara AL; Kuncic Z
Med Phys; 2013 Apr; 40(4):041708. PubMed ID: 23556878
[TBL] [Abstract][Full Text] [Related]
20. Correction of pixel sensitivity variation and off-axis response for amorphous silicon EPID dosimetry.
Greer PB
Med Phys; 2005 Dec; 32(12):3558-68. PubMed ID: 16475754
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]