These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

105 related articles for article (PubMed ID: 22559660)

  • 1. Tomotherapy dose distribution verification using MAGIC-f polymer gel dosimetry.
    Pavoni JF; Pike TL; Snow J; DeWerd L; Baffa O
    Med Phys; 2012 May; 39(5):2877-84. PubMed ID: 22559660
    [TBL] [Abstract][Full Text] [Related]  

  • 2. MAGIC-type polymer gel for three-dimensional dosimetry: intensity-modulated radiation therapy verification.
    Gustavsson H; Karlsson A; Bäck SA; Olsson LE; Haraldsson P; Engström P; Nyström H
    Med Phys; 2003 Jun; 30(6):1264-71. PubMed ID: 12852552
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Three-dimensional quality assurance of IMRT prostate plans using gel dosimetry.
    Silveira MA; Pavoni JF; Baffa O
    Phys Med; 2017 Feb; 34():1-6. PubMed ID: 28108100
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Three-dimensional dose verification for intensity modulated radiation therapy using optical CT based polymer gel dosimetry.
    Wuu CS; Xu Y
    Med Phys; 2006 May; 33(5):1412-9. PubMed ID: 16752577
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Clinical experience with EPID dosimetry for prostate IMRT pre-treatment dose verification.
    McDermott LN; Wendling M; van Asselen B; Stroom J; Sonke JJ; van Herk M; Mijnheer BJ
    Med Phys; 2006 Oct; 33(10):3921-30. PubMed ID: 17089854
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of a composite Gel-Alanine phantom on an end-to-end test to treat multiple brain metastases by a single isocenter VMAT technique.
    Pavoni JF; Neves-Junior WFP; da Silveira MA; Haddad CMK; Baffa O
    Med Phys; 2017 Sep; 44(9):4869-4879. PubMed ID: 28594461
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of polymer gels and MRI as a 3-D dosimeter for intensity-modulated radiation therapy.
    Low DA; Dempsey JF; Venkatesan R; Mutic S; Markman J; Mark Haacke E; Purdy JA
    Med Phys; 1999 Aug; 26(8):1542-51. PubMed ID: 10501054
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Introducing gel dosimetry in a clinical environment: customization of polymer gel composition and magnetic resonance imaging parameters used for 3D dose verifications in radiosurgery and intensity modulated radiotherapy.
    Crescenti RA; Scheib SG; Schneider U; Gianolini S
    Med Phys; 2007 Apr; 34(4):1286-97. PubMed ID: 17500460
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dose verification in clinical IMRT prostate incidents.
    Sandilos P; Angelopoulos A; Baras P; Dardoufas K; Karaiskos P; Kipouros P; Kozicki M; Rosiak JM; Sakelliou L; Seimenis I; Vlahos L
    Int J Radiat Oncol Biol Phys; 2004 Aug; 59(5):1540-7. PubMed ID: 15275742
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Measurement-based Monte Carlo dose calculation system for IMRT pretreatment and on-line transit dose verifications.
    Lin MH; Chao TC; Lee CC; Tung CJ; Yeh CY; Hong JH
    Med Phys; 2009 Apr; 36(4):1167-75. PubMed ID: 19472622
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Treatment plan comparison between helical tomotherapy and MLC-based IMRT using radiobiological measures.
    Mavroidis P; Ferreira BC; Shi C; Lind BK; Papanikolaou N
    Phys Med Biol; 2007 Jul; 52(13):3817-36. PubMed ID: 17664579
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of radiochromic gel dosimetry and polymer gel dosimetry in a clinical dose verification.
    Vandecasteele J; De Deene Y
    Phys Med Biol; 2013 Sep; 58(18):6241-62. PubMed ID: 23965800
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The evaluation of a 2D diode array in "magic phantom" for use in high dose rate brachytherapy pretreatment quality assurance.
    Espinoza A; Petasecca M; Fuduli I; Howie A; Bucci J; Corde S; Jackson M; Lerch ML; Rosenfeld AB
    Med Phys; 2015 Feb; 42(2):663-673. PubMed ID: 28102606
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A dosimetric analysis comparing treatment of low-risk prostate cancer with TomoTherapy versus static field intensity modulated radiation therapy.
    Shah AP; Chen SS; Strauss JB; Kirk MC; Coleman JL; Coon AB; Miller C; Dickler A
    Am J Clin Oncol; 2009 Oct; 32(5):460-6. PubMed ID: 19564784
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Accuracy of out-of-field dose calculation of tomotherapy and cyberknife treatment planning systems: a dosimetric study.
    Schneider U; Hälg RA; Hartmann M; Mack A; Storelli F; Joosten A; Möckli R; Besserer J
    Z Med Phys; 2014 Sep; 24(3):211-5. PubMed ID: 24290992
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dosimetric impacts of gantry angle misalignment on prostate cancer treatment using helical tomotherapy.
    Su FC; Shi C; Crownover R; Swanson G; Papanikolaou N
    Technol Cancer Res Treat; 2008 Aug; 7(4):287-93. PubMed ID: 18642967
    [TBL] [Abstract][Full Text] [Related]  

  • 17. RapidArc treatment verification in 3D using polymer gel dosimetry and Monte Carlo simulation.
    Ceberg S; Gagne I; Gustafsson H; Scherman JB; Korreman SS; Kjaer-Kristoffersen F; Hilts M; Bäck SA
    Phys Med Biol; 2010 Sep; 55(17):4885-98. PubMed ID: 20679702
    [TBL] [Abstract][Full Text] [Related]  

  • 18. An investigation into the dosimetry of a nine-field tomotherapy irradiation using BANG-gel dosimetry.
    Oldham M; Baustert I; Lord C; Smith TA; McJury M; Warrington AP; Leach MO; Webb S
    Phys Med Biol; 1998 May; 43(5):1113-32. PubMed ID: 9623644
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Polymer gel dosimeters for pretreatment radiotherapy verification using the three-dimensional gamma evaluation and pass rate maps.
    Hsieh LL; Shieh JI; Wei LJ; Wang YC; Cheng KY; Shih CT
    Phys Med; 2017 May; 37():75-81. PubMed ID: 28535918
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A Monte Carlo model for independent dose verification in serial tomotherapy.
    Sarkar V; Stathakis S; Papanikolaou N
    Technol Cancer Res Treat; 2008 Oct; 7(5):385-92. PubMed ID: 18783289
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.