BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

227 related articles for article (PubMed ID: 22561083)

  • 1. BD rapid serum tubes reduce false positive plasma troponin T results on the Roche Cobas e411 analyzer.
    Koch CD; Wockenfus AM; Saenger AK; Jaffe AS; Karon BS
    Clin Biochem; 2012 Jul; 45(10-11):842-4. PubMed ID: 22561083
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Use of the BD vacutainer rapid serum tube reduces false-positive results for selected beckman coulter Unicel DxI immunoassays.
    Strathmann FG; Ka MM; Rainey PM; Baird GS
    Am J Clin Pathol; 2011 Aug; 136(2):325-9. PubMed ID: 21757607
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Agreement between troponin T levels from plain and heparinized tubes.
    Jones PG; McClelland A; McNeil A; Gamble G
    Emerg Med (Fremantle); 2001 Dec; 13(4):451-5. PubMed ID: 11903430
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of BD Vacutainer® Rapid Serum Tube and plasma for haemolysis markers in the emergency department.
    Ryan JB; Stuart LA; Southby SJ; Than MP; Mackay R; Florkowski CM; George PM
    Ann Clin Biochem; 2015 Mar; 52(Pt 2):293-6. PubMed ID: 24714681
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The BD Barricor blood collection tube is an acceptable and robust alternative to the PST for use with the Beckman AccuTnI+3 assay.
    Füzéry AK; Raizman JE; Goudreau BL; Moses K; Niemann K; Park J; Cembrowski GS
    Clin Biochem; 2017 Oct; 50(15):851-857. PubMed ID: 28583435
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Rapid serum tubes reduce transport hemolysis and false positive rates for high-sensitivity troponin T.
    Malaeb H; Vera MA; Sangal RB; Venkatesh AK; Possick S; Maciejak L; Oberle E; El-Khoury JM
    Clin Chim Acta; 2023 Nov; 551():117630. PubMed ID: 38420909
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A comparison of stability of chemical analytes in plasma from the BD Vacutainer
    Gawria G; Tillmar L; Landberg E
    J Clin Lab Anal; 2020 Feb; 34(2):e23060. PubMed ID: 31605419
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of the BD Vacutainer(®) RST blood collection tube for routine chemistry analytes: clinical significance of differences and stability study.
    Kocijancic M; Cargonja J; Delic-Knezevic A
    Biochem Med (Zagreb); 2014; 24(3):368-75. PubMed ID: 25351355
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The Influence of Blood Collection Tubes on Measurement of Cardiac Biomarkers.
    Lan H; Du W; Mo Z; Huang H
    Clin Lab; 2016; 62(4):705-9. PubMed ID: 27215091
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of the Becton-Dickinson rapid serum tube: does it provide a suitable alternative to lithium heparin plasma tubes?
    Dimeski G; Masci PP; Trabi M; Lavin MF; de Jersey J
    Clin Chem Lab Med; 2010 May; 48(5):651-7. PubMed ID: 20218902
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of the BD Vacutainer PST II blood collection tube for special chemistry analytes.
    Chance J; Berube J; Vandersmissen M; Blanckaert N
    Clin Chem Lab Med; 2009; 47(3):358-61. PubMed ID: 19676149
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of three different specimen types (serum, plasma lithium heparin and serum gel separator) for analysis of certain analytes: clinical significance of differences in results and efficiency in use.
    O'Keane MP; Cunningham SK
    Clin Chem Lab Med; 2006; 44(5):662-8. PubMed ID: 16681442
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Results from a multicenter evaluation of the 4th generation Elecsys Troponin T assay.
    Hermsen D; Apple F; Garcia-Beltràn L; Jaffe A; Karon B; Lewandrowski E; Mühlbacher A; Müller R; Ordóñez J; Pagani F; Panteghini M; Plecko T; Jarausch J
    Clin Lab; 2007; 53(1-2):1-9. PubMed ID: 17323819
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of the Greiner Bio-One serum separator BCA Fast Clot tube.
    Dimeski G; Johnston J; Masci PP; Zhao KN; Brown N
    Clin Chem Lab Med; 2017 Jul; 55(8):1135-1141. PubMed ID: 28076307
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of BD Vacutainer® Barricor™ blood collection tubes for routine chemistry testing on a Roche Cobas® 8000 Platform.
    Fournier JE; Northrup V; Clark C; Fraser J; Howlett M; Atkinson P; Shea JL
    Clin Biochem; 2018 Aug; 58():94-99. PubMed ID: 29885310
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Rapid troponin T measurement in whole blood for detection of myocardial damage.
    Collinson PO; Thomas S; Siu L; Vasudeva P; Stubbs PJ; Canepa-Anson R
    Ann Clin Biochem; 1995 Sep; 32 ( Pt 5)():454-8. PubMed ID: 8830619
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Analytical performance evaluation of the Elecsys® Troponin T Gen 5 STAT assay.
    Fitzgerald RL; Hollander JE; Peacock WF; Limkakeng AT; Breitenbeck N; Blechschmidt K; Laimighofer M; deFilippi C
    Clin Chim Acta; 2019 Aug; 495():522-528. PubMed ID: 31152695
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The local clinical validation of a new lithium heparin tube with a barrier: BD Vacutainer® Barricor LH Plasma tube.
    Arslan FD; Karakoyun I; Basok BI; Aksit MZ; Baysoy A; Ozturk YK; Guclu YA; Duman C
    Biochem Med (Zagreb); 2017 Oct; 27(3):030706. PubMed ID: 28900369
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Thrombin-mediated degradation of parathyroid hormone in serum tubes.
    La'ulu SL; Straseski JA; Schmidt RL; Genzen JR
    Clin Chim Acta; 2014 Nov; 437():191-6. PubMed ID: 25086279
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Preanalytical variables in measurement of free (ionized) calcium in lithium heparin-containing blood collection tubes.
    Haverstick DM; Brill LB; Scott MG; Bruns DE
    Clin Chim Acta; 2009 May; 403(1-2):102-4. PubMed ID: 19361462
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.