127 related articles for article (PubMed ID: 2256805)
1. Functional evaluation of quadriplegic patients using a hand neuroprosthesis.
Wijman CA; Stroh KC; Van Doren CL; Thrope GB; Peckham PH; Keith MW
Arch Phys Med Rehabil; 1990 Dec; 71(13):1053-7. PubMed ID: 2256805
[TBL] [Abstract][Full Text] [Related]
2. Development of a quantitative hand grasp and release test for patients with tetraplegia using a hand neuroprosthesis.
Wuolle KS; Van Doren CL; Thrope GB; Keith MW; Peckham PH
J Hand Surg Am; 1994 Mar; 19(2):209-18. PubMed ID: 8201183
[TBL] [Abstract][Full Text] [Related]
3. Efficacy of an implanted neuroprosthesis for restoring hand grasp in tetraplegia: a multicenter study.
Peckham PH; Keith MW; Kilgore KL; Grill JH; Wuolle KS; Thrope GB; Gorman P; Hobby J; Mulcahey MJ; Carroll S; Hentz VR; Wiegner A;
Arch Phys Med Rehabil; 2001 Oct; 82(10):1380-8. PubMed ID: 11588741
[TBL] [Abstract][Full Text] [Related]
4. Instrumented objects for quantitative evaluation of hand grasp.
Memberg WD; Crago PE
J Rehabil Res Dev; 1997 Jan; 34(1):82-90. PubMed ID: 9021628
[TBL] [Abstract][Full Text] [Related]
5. Functional evaluation of natural sensory feedback incorporated in a hand grasp neuroprosthesis.
Inmann A; Haugland M
Med Eng Phys; 2004 Jul; 26(6):439-47. PubMed ID: 15234680
[TBL] [Abstract][Full Text] [Related]
6. Restoration of tetraplegic hand function by use of the neurocontrol freehand system.
Hobby J; Taylor PN; Esnouf J
J Hand Surg Br; 2001 Oct; 26(5):459-64. PubMed ID: 11560429
[TBL] [Abstract][Full Text] [Related]
7. Functional electrical stimulation in tetraplegic patients to restore hand function.
Degnan GG; Wind TC; Jones EV; Edlich RF
J Long Term Eff Med Implants; 2002; 12(3):175-88. PubMed ID: 12545943
[TBL] [Abstract][Full Text] [Related]
8. Implementation of natural sensory feedback in a portable control system for a hand grasp neuroprosthesis.
Inmann A; Haugland M
Med Eng Phys; 2004 Jul; 26(6):449-58. PubMed ID: 15234681
[TBL] [Abstract][Full Text] [Related]
9. An analysis of the input-output properties of neuroprosthetic hand grasps.
Memberg WD; Crago PE
J Rehabil Res Dev; 2000; 37(1):11-21. PubMed ID: 10847568
[TBL] [Abstract][Full Text] [Related]
10. Long-term user perceptions of an implanted neuroprosthesis for exercise, standing, and transfers after spinal cord injury.
Agarwal S; Triolo RJ; Kobetic R; Miller M; Bieri C; Kukke S; Rohde L; Davis JA
J Rehabil Res Dev; 2003; 40(3):241-52. PubMed ID: 14582528
[TBL] [Abstract][Full Text] [Related]
11. Australian experience with the Freehand System for restoring grasp in quadriplegia.
Carroll S; Cooper C; Brown D; Sormann G; Flood S; Denison M
Aust N Z J Surg; 2000 Aug; 70(8):563-8. PubMed ID: 10945548
[TBL] [Abstract][Full Text] [Related]
12. Implanted neuroprosthesis for restoring arm and hand function in people with high level tetraplegia.
Memberg WD; Polasek KH; Hart RL; Bryden AM; Kilgore KL; Nemunaitis GA; Hoyen HA; Keith MW; Kirsch RF
Arch Phys Med Rehabil; 2014 Jun; 95(6):1201-1211.e1. PubMed ID: 24561055
[TBL] [Abstract][Full Text] [Related]
13. Automated tuning of a closed-loop hand grasp neuroprosthesis.
Lemay MA; Crago PE; Katorgi M; Chapman GJ
IEEE Trans Biomed Eng; 1993 Jul; 40(7):675-85. PubMed ID: 8244428
[TBL] [Abstract][Full Text] [Related]
14. Persons with C5 or C6 tetraplegia achieve selected functional gains using a neuroprosthesis.
Alon G; McBride K
Arch Phys Med Rehabil; 2003 Jan; 84(1):119-24. PubMed ID: 12589632
[TBL] [Abstract][Full Text] [Related]
15. An implanted upper-extremity neuroprosthesis using myoelectric control.
Kilgore KL; Hoyen HA; Bryden AM; Hart RL; Keith MW; Peckham PH
J Hand Surg Am; 2008 Apr; 33(4):539-50. PubMed ID: 18406958
[TBL] [Abstract][Full Text] [Related]
16. Neuroprosthetics of the upper extremity--clinical application in spinal cord injury and future perspectives.
Rupp R; Gerner HJ
Biomed Tech (Berl); 2004 Apr; 49(4):93-8. PubMed ID: 15171589
[TBL] [Abstract][Full Text] [Related]
17. Input-output nonlinearities and time delays increase tracking errors in hand grasp neuroprostheses.
Adamczyk MM; Crago PE
IEEE Trans Rehabil Eng; 1996 Dec; 4(4):271-9. PubMed ID: 8973953
[TBL] [Abstract][Full Text] [Related]
18. An advanced neuroprosthesis for restoration of hand and upper arm control using an implantable controller.
Peckham PH; Kilgore KL; Keith MW; Bryden AM; Bhadra N; Montague FW
J Hand Surg Am; 2002 Mar; 27(2):265-76. PubMed ID: 11901386
[TBL] [Abstract][Full Text] [Related]
19. Wireless wearable controller for upper-limb neuroprosthesis.
Wheeler CA; Peckham PH
J Rehabil Res Dev; 2009; 46(2):243-56. PubMed ID: 19533538
[TBL] [Abstract][Full Text] [Related]
20. Functional neuromuscular stimulation neuroprostheses for the tetraplegic hand.
Keith MW; Peckham PH; Thrope GB; Buckett JR; Stroh KC; Menger V
Clin Orthop Relat Res; 1988 Aug; (233):25-33. PubMed ID: 3042233
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]