These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

158 related articles for article (PubMed ID: 22581141)

  • 1. A system for seismocardiography-based identification of quiescent heart phases: implications for cardiac imaging.
    Wick CA; Su JJ; McClellan JH; Brand O; Bhatti PT; Buice AL; Stillman AE; Tang X; Tridandapani S
    IEEE Trans Inf Technol Biomed; 2012 Sep; 16(5):869-77. PubMed ID: 22581141
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Relationship between cardiac quiescent periods derived from seismocardiography and echocardiography.
    Wick CA; Inan OT; Bhatti P; Tridandapani S
    Annu Int Conf IEEE Eng Med Biol Soc; 2015 Aug; 2015():687-90. PubMed ID: 26736355
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Seismocardiography-Based Detection of Cardiac Quiescence.
    Wick CA; Inan OT; McClellan JH; Tridandapani S
    IEEE Trans Biomed Eng; 2015 Aug; 62(8):2025-32. PubMed ID: 25769145
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Seismocardiography-Based Cardiac Computed Tomography Gating Using Patient-Specific Template Identification and Detection.
    Yao J; Tridandapani S; Wick CA; Bhatti PT
    IEEE J Transl Eng Health Med; 2017; 5():1900314. PubMed ID: 28845370
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Wearable seismocardiography: towards a beat-by-beat assessment of cardiac mechanics in ambulant subjects.
    Di Rienzo M; Vaini E; Castiglioni P; Merati G; Meriggi P; Parati G; Faini A; Rizzo F
    Auton Neurosci; 2013 Nov; 178(1-2):50-9. PubMed ID: 23664242
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Seismocardiography-based detection of cardiac quiescence for cardiac computed tomography angiography.
    Wick CA; McClellan JH; Inan OT; Tridandapani S
    Annu Int Conf IEEE Eng Med Biol Soc; 2014; 2014():6080-4. PubMed ID: 25571384
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A trimodal system for the acquisition of synchronous echocardiography, electrocardiography, and seismocardiography data.
    Wick CA; Su JJ; Brand O; McClellan JH; Bhatti PT; Tridandapani S
    Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():6911-4. PubMed ID: 22255927
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Definition of Fiducial Points in the Normal Seismocardiogram.
    Sørensen K; Schmidt SE; Jensen AS; Søgaard P; Struijk JJ
    Sci Rep; 2018 Oct; 8(1):15455. PubMed ID: 30337579
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Identification of Location Specific Feature Points in a Cardiac Cycle Using a Novel Seismocardiogram Spectrum System.
    Lin WY; Chou WC; Chang PC; Chou CC; Wen MS; Ho MY; Lee WC; Hsieh MJ; Lin CC; Tsai TH; Lee MY
    IEEE J Biomed Health Inform; 2018 Mar; 22(2):442-449. PubMed ID: 28113792
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Automatic Detection of Aortic Valve Opening Using Seismocardiography in Healthy Individuals.
    Choudhary T; Sharma LN; Bhuyan MK
    IEEE J Biomed Health Inform; 2019 May; 23(3):1032-1040. PubMed ID: 29993702
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An Adaptive Seismocardiography (SCG)-ECG Multimodal Framework for Cardiac Gating Using Artificial Neural Networks.
    Yao J; Tridandapani S; Auffermann WF; Wick CA; Bhatti PT
    IEEE J Transl Eng Health Med; 2018; 6():1900611. PubMed ID: 30405976
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A Novel Adaptive Recursive Least Squares Filter to Remove the Motion Artifact in Seismocardiography.
    Yu S; Liu S
    Sensors (Basel); 2020 Mar; 20(6):. PubMed ID: 32182977
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Real-Time Cardiac Beat Detection and Heart Rate Monitoring from Combined Seismocardiography and Gyrocardiography.
    D'Mello Y; Skoric J; Xu S; Roche PJR; Lortie M; Gagnon S; Plant DV
    Sensors (Basel); 2019 Aug; 19(16):. PubMed ID: 31398948
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Investigating the estimation of cardiac time intervals using gyrocardiography.
    Dehkordi P; Tavakolian K; Tadi MJ; Zakeri V; Khosrow-Khavar F
    Physiol Meas; 2020 Jun; 41(5):055004. PubMed ID: 32268315
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Detection of quiescent cardiac phases in echocardiography data using nonlinear filtering and boundary detection techniques.
    Ravichandran L; Wick CA; McClellan JH; Liu T; Tridandapani S
    J Digit Imaging; 2014 Oct; 27(5):625-32. PubMed ID: 24859726
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Seismocardiography and echocardiography: the correlation in the systolic complex.
    Kolind CM; Tange AB; Sten ST; Sonne MMS; Agam A; Søgaard P; Schmidt S
    Biomed Phys Eng Express; 2024 Aug; 10(5):. PubMed ID: 39094605
    [No Abstract]   [Full Text] [Related]  

  • 17. Echocardiography as an indication of continuous-time cardiac quiescence.
    Wick CA; Auffermann WF; Shah AJ; Inan OT; Bhatti PT; Tridandapani S
    Phys Med Biol; 2016 Jul; 61(14):5297-310. PubMed ID: 27362455
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Heartbeat Detection in Gyrocardiography Signals without Concurrent ECG Tracings.
    Parlato S; Centracchio J; Esposito D; Bifulco P; Andreozzi E
    Sensors (Basel); 2023 Jul; 23(13):. PubMed ID: 37448046
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Extracting respiratory information from seismocardiogram signals acquired on the chest using a miniature accelerometer.
    Pandia K; Inan OT; Kovacs GT; Giovangrandi L
    Physiol Meas; 2012 Oct; 33(10):1643-60. PubMed ID: 22986375
    [TBL] [Abstract][Full Text] [Related]  

  • 20. 24h seismocardiogram monitoring in ambulant subjects.
    Di Rienzo M; Meriggi P; Vaini E; Castiglioni P; Rizzo F
    Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():5050-3. PubMed ID: 23367063
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.