These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

319 related articles for article (PubMed ID: 22581201)

  • 1. A technique for placement of a bioabsorbable prosthesis with fibrin glue fixation for reinforcement of the crural closure during hiatal hernia repair.
    Powell BS; Wandrey D; Voeller GR
    Hernia; 2013 Feb; 17(1):81-4. PubMed ID: 22581201
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Resorbable biosynthetic mesh for crural reinforcement during hiatal hernia repair.
    Alicuben ET; Worrell SG; DeMeester SR
    Am Surg; 2014 Oct; 80(10):1030-3. PubMed ID: 25264654
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Laparoscopic fixation of biological mesh at hiatus with glue and suture during hiatal hernia repair.
    Nie Y; Xiong Y; Guan L; Yuan X; Chen F; Chen J; Yang H
    BMC Surg; 2021 Mar; 21(1):158. PubMed ID: 33752652
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Short-term results for laparoscopic repair of large paraesophageal hiatal hernias with Gore Bio A® mesh.
    Priego Jiménez P; Salvador Sanchís JL; Angel V; Escrig-Sos J
    Int J Surg; 2014; 12(8):794-7. PubMed ID: 24947948
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Combination of Surgical Technique and Bioresorbable Mesh Reinforcement of the Crural Repair Leads to Low Early Hernia Recurrence Rates with Laparoscopic Paraesophageal Hernia Repair.
    Abdelmoaty WF; Dunst CM; Filicori F; Zihni AM; Davila-Bradley D; Reavis KM; Swanstrom LL; DeMeester SR
    J Gastrointest Surg; 2020 Jul; 24(7):1477-1481. PubMed ID: 31468330
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Preliminary report of a sutureless onlay technique for incisional hernia repair using fibrin glue alone for mesh fixation.
    Stoikes N; Webb D; Powell B; Voeller G
    Am Surg; 2013 Nov; 79(11):1177-80. PubMed ID: 24165253
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Prosthetic bioabsorbable mesh for hiatal hernia repair during sleeve gastrectomy.
    Clapp B
    JSLS; 2013; 17(4):641-4. PubMed ID: 24398209
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Impact of crural relaxing incisions, Collis gastroplasty, and non-cross-linked human dermal mesh crural reinforcement on early hiatal hernia recurrence rates.
    Alicuben ET; Worrell SG; DeMeester SR
    J Am Coll Surg; 2014 Nov; 219(5):988-92. PubMed ID: 25256373
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Hiatal hernia repair with biologic mesh reinforcement reduces recurrence rate in small hiatal hernias.
    Schmidt E; Shaligram A; Reynoso JF; Kothari V; Oleynikov D
    Dis Esophagus; 2014 Jan; 27(1):13-7. PubMed ID: 23441634
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The use of crural relaxing incisions with biologic mesh reinforcement during laparoscopic repair of complex hiatal hernias.
    Crespin OM; Yates RB; Martin AV; Pellegrini CA; Oelschlager BK
    Surg Endosc; 2016 Jun; 30(6):2179-85. PubMed ID: 26335079
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Hiatoplasty reinforcement by means of a lightweight titanized polypropylene mesh fixed with fibrin glue].
    Kanellos D; Moesta KT; Schug-Pass C; Köckerling F
    Zentralbl Chir; 2011 Jun; 136(3):244-8. PubMed ID: 20309806
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Hiatal Hernia Repair with Novel Biological Graft Reinforcement.
    Sasse KC; Warner DL; Ackerman E; Brandt J
    JSLS; 2016; 20(2):. PubMed ID: 27186066
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Laparoscopic management of large hiatal hernia: mesh method with the use of ProGrip mesh versus standard crural repair.
    Ilyashenko VV; Grubnyk VV; Grubnik VV
    Surg Endosc; 2018 Aug; 32(8):3592-3598. PubMed ID: 29423552
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Fibrin sealant (Tisseel) for hiatal mesh fixation in an experimental model in pigs.
    Fortelny RH; Petter-Puchner AH; Glaser KS; Keibl C; Gruber-Blum S; Ohlinger W; Redl H
    J Surg Res; 2010 Jul; 162(1):68-74. PubMed ID: 19815234
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fibrin sealant (Tissucol) for the fixation of hiatal mesh in the repair of giant paraesophageal hernia: a case report.
    Fortelny RH; Petter-Puchner AH; Glaser KS
    Surg Laparosc Endosc Percutan Tech; 2009 Jun; 19(3):e91-4. PubMed ID: 19542837
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Reinforcement of hiatal defect repair with absorbable mesh fixed with non-permanent devices.
    Silecchia G; Iossa A; Cavallaro G; Rizzello M; Longo F
    Minim Invasive Ther Allied Technol; 2014 Oct; 23(5):302-8. PubMed ID: 24773371
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of lightweight titanium-coated polypropylene mesh (TiMesh) for laparoscopic repair of large hiatal hernias.
    Hazebroek EJ; Ng A; Yong DH; Berry H; Leibman S; Smith GS
    Surg Endosc; 2008 Nov; 22(11):2428-32. PubMed ID: 18626699
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Review of 1000 fibrin glue mesh fixation during endoscopic totally extraperitoneal (TEP) inguinal hernia repair.
    Berney CR; Descallar J
    Surg Endosc; 2016 Oct; 30(10):4544-52. PubMed ID: 26895903
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Mesh erosion after hiatal hernia repair: the tip of the iceberg?
    Li J; Cheng T
    Hernia; 2019 Dec; 23(6):1243-1252. PubMed ID: 31338721
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of fibrin sealant for biologic mesh fixation at the hiatus in a porcine model.
    Krpata DM; Blatnik JA; Harth KC; Phillips MS; Novitsky YW; Rosen MJ
    Surg Endosc; 2012 Nov; 26(11):3120-6. PubMed ID: 22538698
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.