BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

176 related articles for article (PubMed ID: 22583195)

  • 1. How should we investigate breast implant rupture?
    Hold PM; Alam S; Pilbrow WJ; Kelly JF; Everitt EM; Dhital SK; Juma A
    Breast J; 2012; 18(3):253-6. PubMed ID: 22583195
    [TBL] [Abstract][Full Text] [Related]  

  • 2. High-resolution ultrasound in the detection of silicone gel breast implant shell failure: background, in vitro studies, and early clinical results.
    Bengtson BP; Eaves FF
    Aesthet Surg J; 2012 Feb; 32(2):157-74. PubMed ID: 22328687
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ultrasonographic appearance of breast implant complications.
    Cilotti A; Marini C; Iacconi C; Mazzotta D; Moretti M; Giaconi C; Bartolozzi C
    Ann Plast Surg; 2006 Mar; 56(3):243-7. PubMed ID: 16508351
    [No Abstract]   [Full Text] [Related]  

  • 4. Analysis of 109 Consecutive Explanted Breast Implants: Correlation Between Suspected Implant Rupture and Surgical Findings.
    Maisel Lotan A; Retchkiman M; Tuchman I; Binenboym R; Gronovich Y
    Aesthetic Plast Surg; 2016 Oct; 40(5):739-44. PubMed ID: 27514822
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Ultrasonography is more useful in assessment of suspected breast implant infections rather than capsular contracture.
    Patel AJ
    Ann Plast Surg; 2006 Oct; 57(4):477-8. PubMed ID: 16998351
    [No Abstract]   [Full Text] [Related]  

  • 6. The diagnosis of silicone breast-implant rupture: clinical findings compared with findings at magnetic resonance imaging.
    Hölmich LR; Fryzek JP; Kjøller K; Breiting VB; Jørgensen A; Krag C; McLaughlin JK
    Ann Plast Surg; 2005 Jun; 54(6):583-9. PubMed ID: 15900139
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Efficacy of ultrasound, mammography and magnetic resonance imaging in detecting breast implant rupture: A retrospective study of 175 reconstructive and aesthetic sub-pectoral breast augmentation cases.
    Stivala A; Rem K; Leuzzi S; Moris V; François C; Revol M; Cristofari S
    J Plast Reconstr Aesthet Surg; 2017 Nov; 70(11):1520-1526. PubMed ID: 28739171
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Decision-analysis methodology in the work-up of women with suspected silicone breast implant rupture.
    Chung KC; Greenfield ML; Walters M
    Plast Reconstr Surg; 1998 Sep; 102(3):689-95. PubMed ID: 9727432
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The diagnosis of silicone breast implant rupture.
    Gorczyca DP; Gorczyca SM; Gorczyca KL
    Plast Reconstr Surg; 2007 Dec; 120(7 Suppl 1):49S-61S. PubMed ID: 18090814
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The ruptured PIP breast implant.
    Helyar V; Burke C; McWilliams S
    Clin Radiol; 2013 Aug; 68(8):845-50. PubMed ID: 23622796
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Silicone Breast Implant Rupture in a 70-year-old Woman Presenting with Multiple Superficial Nodules.
    Abbatemarco J; Dornblaser D; Buccola J; Patell R
    J Gen Intern Med; 2017 Jan; 32(1):131-132. PubMed ID: 27271727
    [No Abstract]   [Full Text] [Related]  

  • 12. The diagnosis of breast implant rupture: MRI findings compared with findings at explantation.
    Hölmich LR; Vejborg I; Conrad C; Sletting S; McLaughlin JK
    Eur J Radiol; 2005 Feb; 53(2):213-25. PubMed ID: 15664285
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparative silicone breast implant evaluation using mammography, sonography, and magnetic resonance imaging: experience with 59 implants.
    Ahn CY; DeBruhl ND; Gorczyca DP; Shaw WW; Bassett LW
    Plast Reconstr Surg; 1994 Oct; 94(5):620-7. PubMed ID: 7938284
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The sonographic appearances of breast implant rupture.
    Lake E; Ahmad S; Dobrashian R
    Clin Radiol; 2013 Aug; 68(8):851-8. PubMed ID: 23623260
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Is breast ultrasound a good alternative to magnetic resonance imaging for evaluating implant integrity?
    Secco GM; Gutierrez PA; Secco VL; Chico MJ; Secco RA; Pesce KA
    Radiologia (Engl Ed); 2022 Mar; 64 Suppl 1():20-27. PubMed ID: 35428463
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Diagnostic value of clinical examination and various imaging techniques for breast implant rupture as determined in 81 patients having implant removal.
    Netscher DT; Weizer G; Malone RS; Walker LE; Thornby J; Patten BM
    South Med J; 1996 Apr; 89(4):397-404. PubMed ID: 8614880
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparative study of breast implant rupture using mammography, sonography, and magnetic resonance imaging: correlation with surgical findings.
    Di Benedetto G; Cecchini S; Grassetti L; Baldassarre S; Valeri G; Leva L; Giuseppetti GM; Bertani A
    Breast J; 2008; 14(6):532-7. PubMed ID: 19054000
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The PIP mammary prosthesis: a product recall study.
    Berry MG; Stanek JJ
    J Plast Reconstr Aesthet Surg; 2012 Jun; 65(6):697-704. PubMed ID: 22405818
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Diagnosis of silicone gel breast implant rupture by ultrasonography.
    Chung KC; Wilkins EG; Beil RJ; Helvie MA; Ikeda DM; Oneal RM; Forrest ME; Smith DJ
    Plast Reconstr Surg; 1996 Jan; 97(1):104-9. PubMed ID: 8532766
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Utility of magnetic resonance imaging and ultrasonography in diagnosing breast implant rupture.
    Weizer G; Malone RS; Netscher DT; Walker LE; Thornby J
    Ann Plast Surg; 1995 Apr; 34(4):352-61. PubMed ID: 7793779
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.