These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
221 related articles for article (PubMed ID: 22595412)
1. Perfect correspondence of mitral valve perforation using real-time 3-dimensional transesophageal echocardiography. Tada H; Masuta E; Mori M; Tsubokawa T; Konno T; Hayashi K; Uchiyama K; Kawashiri MA; Tomita S; Watanabe G; Yamagishi M J Am Coll Cardiol; 2012 May; 59(21):1914. PubMed ID: 22595412 [No Abstract] [Full Text] [Related]
2. Diagnosis of cleft mitral valve using real-time 3-dimensional transesophageal echocardiography. Looi JL; Lee AP; Wan S; Wong RH; Underwood MJ; Lam YY; Yu CM Int J Cardiol; 2013 Sep; 168(2):1629-30. PubMed ID: 23478197 [No Abstract] [Full Text] [Related]
3. Utility of three-dimensional transesophageal echocardiography: anatomy, mechanism, and severity of regurgitation in a patient with an isolated cleft posterior mitral valve. Biaggi P; Greutmann M; Crean A J Am Soc Echocardiogr; 2010 Oct; 23(10):1114.e1-4. PubMed ID: 20452183 [TBL] [Abstract][Full Text] [Related]
5. Echocardiography in mitral regurgitation with relevance to valve surgery. Shah PM; Raney AA J Am Soc Echocardiogr; 2011 Oct; 24(10):1086-91. PubMed ID: 21933744 [No Abstract] [Full Text] [Related]
6. 3-D assessment of infective endocarditis with anterior mitral valve perforation and flail posterior leaflet. Butler TC; Sedgwick JF; Burstow DJ Int J Cardiol; 2015 Apr; 185():249. PubMed ID: 25814211 [No Abstract] [Full Text] [Related]
7. Isolated Cleft of the Posterior Mitral Valve Leaflet: The Value of 3DTEE in the Evaluation of Mitral Valve Anatomy. Guerreiro C; Fonseca C; Ribeiro J; Fontes-Carvalho R Echocardiography; 2016 Aug; 33(8):1265-6. PubMed ID: 27112582 [No Abstract] [Full Text] [Related]
8. The dynamics of mitral valve function: lessons to be learned from three-dimensional echocardiography. Mittnacht AJC; Sengupta PP J Cardiothorac Vasc Anesth; 2014 Feb; 28(1):8-10. PubMed ID: 24440008 [No Abstract] [Full Text] [Related]
9. Surgical Echocardiography of the MV: Focus on 3D. Bhatia M; Kumar P; Martinelli SM Semin Cardiothorac Vasc Anesth; 2019 Mar; 23(1):26-36. PubMed ID: 30020031 [TBL] [Abstract][Full Text] [Related]
10. Real-time 3-dimensional transesophageal echocardiography in the assessment of ventriculoatrial shunt (Gerbode defect) complicating simultaneous mitral and tricuspid valve repair. Chamsi-Pasha MA; Sayyed SH; Moulton MJ J Am Coll Cardiol; 2014 Apr; 63(15):e37. PubMed ID: 24583307 [No Abstract] [Full Text] [Related]
11. Comparison of real-time three-dimensional transesophageal echocardiography to two-dimensional transesophageal echocardiography for quantification of mitral valve prolapse in patients with severe mitral regurgitation. Izumo M; Shiota M; Kar S; Gurudevan SV; Tolstrup K; Siegel RJ; Shiota T Am J Cardiol; 2013 Feb; 111(4):588-94. PubMed ID: 23206924 [TBL] [Abstract][Full Text] [Related]
12. Three-Dimensional Echocardiography: A Powerful New Tool in the Evaluation of Mitral Annular Structure and Dynamics. Pressman GS; Movva R; Topilsky Y; Clavel MA; Saldanha JA; Watanabe N; Enriquez-Sarano M J Am Soc Echocardiogr; 2015 Oct; 28(10):1256-7. PubMed ID: 26298098 [No Abstract] [Full Text] [Related]
13. Revealing infective endocarditis complications by echocardiography: the value of real-time 3D transesophageal echocardiography. Vrettou AR; Zacharoulis A; Lerakis S; Kremastinos DT Hellenic J Cardiol; 2013; 54(2):147-9. PubMed ID: 23557617 [TBL] [Abstract][Full Text] [Related]
14. Paravalvular leak after mitral valve replacement: advantage of 3D echo. Singh SP; Hasija S; Chauhan S Ann Card Anaesth; 2014; 17(2):137-8. PubMed ID: 24732614 [No Abstract] [Full Text] [Related]