These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

317 related articles for article (PubMed ID: 22596067)

  • 1. Hemolytic and thrombocytopathic characteristics of extracorporeal membrane oxygenation systems at simulated flow rate for neonates.
    Meyer AD; Wiles AA; Rivera O; Wong EC; Freishtat RJ; Rais-Bahrami K; Dalton HJ
    Pediatr Crit Care Med; 2012 Jul; 13(4):e255-61. PubMed ID: 22596067
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hemolytic characteristics of three commercially available centrifugal blood pumps.
    Lawson DS; Ing R; Cheifetz IM; Walczak R; Craig D; Schulman S; Kern F; Shearer IR; Lodge A; Jaggers J
    Pediatr Crit Care Med; 2005 Sep; 6(5):573-7. PubMed ID: 16148820
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Platelet-derived microparticles generated by neonatal extracorporeal membrane oxygenation systems.
    Meyer AD; Gelfond JA; Wiles AA; Freishtat RJ; Rais-Bahrami K
    ASAIO J; 2015; 61(1):37-42. PubMed ID: 25303795
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Laboratory Evaluation of Hemolysis and Systemic Inflammatory Response in Neonatal Nonpulsatile and Pulsatile Extracorporeal Life Support Systems.
    Wang S; Krawiec C; Patel S; Kunselman AR; Song J; Lei F; Baer LD; Ündar A
    Artif Organs; 2015 Sep; 39(9):774-81. PubMed ID: 25940752
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Hemolysis in pediatric patients receiving centrifugal-pump extracorporeal membrane oxygenation: prevalence, risk factors, and outcomes.
    Lou S; MacLaren G; Best D; Delzoppo C; Butt W
    Crit Care Med; 2014 May; 42(5):1213-20. PubMed ID: 24351369
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In Vitro Comparison of Two Neonatal ECMO Circuits Using a Roller or Centrifugal Pump With Three Different In-Line Hemoconcentrators for Maintaining Hemodynamic Energy Delivery to the Patient.
    Force M; Moroi M; Wang S; Palanzo DA; Kunselman AR; Ündar A
    Artif Organs; 2018 Apr; 42(4):354-364. PubMed ID: 29323409
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Extracorporeal life support systems: alternative vs. conventional circuits.
    Khan S; Vasavada R; Qiu F; Kunselman A; Undar A
    Perfusion; 2011 May; 26(3):191-8. PubMed ID: 21227982
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of Combined Extracorporeal Life Support and Continuous Renal Replacement Therapy on Hemodynamic Performance and Gaseous Microemboli Handling Ability in a Simulated Neonatal ECLS System.
    Shank KR; Profeta E; Wang S; O'Connor C; Kunselman AR; Woitas K; Myers JL; Ündar A
    Artif Organs; 2018 Apr; 42(4):365-376. PubMed ID: 28940550
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Extracorporeal membrane oxygenator compatible with centrifugal blood pumps.
    Motomura T; Maeda T; Kawahito S; Matsui T; Ichikawa S; Ishitoya H; Kawamura M; Nishimura I; Shinohara T; Oestmann D; Glueck J; Kawaguchi Y; Sato K; Nosé Y
    Artif Organs; 2002 Nov; 26(11):952-8. PubMed ID: 12406150
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Building a Better Neonatal Extracorporeal Life Support Circuit: Comparison of Hemodynamic Performance and Gaseous Microemboli Handling in Different Pump and Oxygenator Technologies.
    Glass K; Trivedi P; Wang S; Woitas K; Kunselman AR; Ündar A
    Artif Organs; 2017 Apr; 41(4):392-400. PubMed ID: 28397410
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Does an Open Recirculation Line Affect the Flow Rate and Pressure in a Neonatal Extracorporeal Life Support Circuit With a Centrifugal or Roller Pump?
    Wang S; Spencer SB; Woitas K; Glass K; Kunselman AR; Ündar A
    Artif Organs; 2017 Jan; 41(1):70-75. PubMed ID: 27862035
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Centrifugal pumps and hemolysis in pediatric extracorporeal membrane oxygenation (ECMO) patients: An analysis of Extracorporeal Life Support Organization (ELSO) registry data.
    O'Brien C; Monteagudo J; Schad C; Cheung E; Middlesworth W
    J Pediatr Surg; 2017 Jun; 52(6):975-978. PubMed ID: 28359588
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Outcomes of Infants Supported With Extracorporeal Membrane Oxygenation Using Centrifugal Versus Roller Pumps: An Analysis From the Extracorporeal Life Support Organization Registry.
    O'Halloran CP; Thiagarajan RR; Yarlagadda VV; Barbaro RP; Nasr VG; Rycus P; Anders M; Alexander PMA
    Pediatr Crit Care Med; 2019 Dec; 20(12):1177-1184. PubMed ID: 31567621
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Oxygenator Impact on Ceftolozane and Tazobactam in Extracorporeal Membrane Oxygenation Circuits.
    Cies JJ; Moore WS; Giliam N; Low T; Enache A; Chopra A
    Pediatr Crit Care Med; 2020 Mar; 21(3):276-282. PubMed ID: 31688715
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Circuit oxygenator contributes to extracorporeal membrane oxygenation-induced hemolysis.
    Williams DC; Turi JL; Hornik CP; Bonadonna DK; Williford WL; Walczak RJ; Watt KM; Cheifetz IM
    ASAIO J; 2015; 61(2):190-5. PubMed ID: 25419829
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Centrifugal or Roller Blood Pumps for Neonatal Venovenous Extracorporeal Membrane Oxygenation: Extracorporeal Life Support Organization Database Comparison of Mortality and Morbidity.
    Ündar A; Kunselman AR; Barbaro RP; Alexander P; Patel K; Thomas NJ
    Pediatr Crit Care Med; 2023 Aug; 24(8):662-669. PubMed ID: 37102713
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Oxygenator Impact on Ceftaroline in Extracorporeal Membrane Oxygenation Circuits.
    Cies JJ; Moore WS; Giliam N; Low T; Enache A; Chopra A
    Pediatr Crit Care Med; 2018 Nov; 19(11):1077-1082. PubMed ID: 30048366
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of oxygenators and centrifugal pumps for long-term pediatric extracorporeal membrane oxygenation.
    Thiara AP; Hoel TN; Kristiansen F; Karlsen HM; Fiane AE; Svennevig JL
    Perfusion; 2007 Sep; 22(5):323-6. PubMed ID: 18416217
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Outcomes of neonates undergoing extracorporeal membrane oxygenation support using centrifugal versus roller blood pumps.
    Barrett CS; Jaggers JJ; Cook EF; Graham DA; Rajagopal SK; Almond CS; Seeger JD; Rycus PT; Thiagarajan RR
    Ann Thorac Surg; 2012 Nov; 94(5):1635-41. PubMed ID: 22921236
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effects of centrifugal and roller pumps on survival of autologous red cells in cardiopulmonary bypass surgery.
    Valeri CR; MacGregor H; Ragno G; Healey N; Fonger J; Khuri SF
    Perfusion; 2006 Dec; 21(5):291-6. PubMed ID: 17201084
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.