These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
851 related articles for article (PubMed ID: 22608432)
1. A highly sensitive electrochemical assay for silver ion detection based on un-labeled C-rich ssDNA probe and controlled assembly of MWCNTs. Yan G; Wang Y; He X; Wang K; Su J; Chen Z; Qing Z Talanta; 2012 May; 94():178-83. PubMed ID: 22608432 [TBL] [Abstract][Full Text] [Related]
2. The Ag+-G interaction inhibits the electrocatalytic oxidation of guanine--a novel mechanism for Ag+ detection. Liu X; Li W; Shen Q; Nie Z; Guo M; Han Y; Liu W; Yao S Talanta; 2011 Sep; 85(3):1603-8. PubMed ID: 21807228 [TBL] [Abstract][Full Text] [Related]
3. A highly sensitive label-free electrochemical aptasensor for interferon-gamma detection based on graphene controlled assembly and nuclease cleavage-assisted target recycling amplification. Yan G; Wang Y; He X; Wang K; Liu J; Du Y Biosens Bioelectron; 2013 Jun; 44():57-63. PubMed ID: 23391707 [TBL] [Abstract][Full Text] [Related]
4. Sensitive DNA biosensor improved by Luteolin copper(II) as indicator based on silver nanoparticles and carbon nanotubes modified electrode. Niu S; Han B; Cao W; Zhang S Anal Chim Acta; 2009 Sep; 651(1):42-7. PubMed ID: 19733733 [TBL] [Abstract][Full Text] [Related]
5. Selective detection of silver ions using mushroom-like polyaniline and gold nanoparticle nanocomposite-based electrochemical DNA sensor. Yang Y; Zhang S; Kang M; He L; Zhao J; Zhang H; Zhang Z Anal Biochem; 2015 Dec; 490():7-13. PubMed ID: 26292168 [TBL] [Abstract][Full Text] [Related]
6. Label-free and sequence-specific DNA detection down to a picomolar level with carbon nanotubes as support for probe DNA. Zhu N; Lin Y; Yu P; Su L; Mao L Anal Chim Acta; 2009 Sep; 650(1):44-8. PubMed ID: 19720171 [TBL] [Abstract][Full Text] [Related]
7. A novel nonenzymatic hydrogen peroxide sensor based on multi-wall carbon nanotube/silver nanoparticle nanohybrids modified gold electrode. Zhao W; Wang H; Qin X; Wang X; Zhao Z; Miao Z; Chen L; Shan M; Fang Y; Chen Q Talanta; 2009 Dec; 80(2):1029-33. PubMed ID: 19836592 [TBL] [Abstract][Full Text] [Related]
8. A label-free electrochemical assay for methyltransferase activity detection based on the controllable assembly of single wall carbon nanotubes. Wang Y; He X; Wang K; Su J; Chen Z; Yan G; Du Y Biosens Bioelectron; 2013 Mar; 41():238-43. PubMed ID: 22947514 [TBL] [Abstract][Full Text] [Related]
9. Electrochemical sensing and biosensing platform based on chemically reduced graphene oxide. Zhou M; Zhai Y; Dong S Anal Chem; 2009 Jul; 81(14):5603-13. PubMed ID: 19522529 [TBL] [Abstract][Full Text] [Related]
10. Electrochemical sensor based on electrodeposited graphene-Au modified electrode and nanoAu carrier amplified signal strategy for attomolar mercury detection. Zhang Y; Zeng GM; Tang L; Chen J; Zhu Y; He XX; He Y Anal Chem; 2015 Jan; 87(2):989-96. PubMed ID: 25440021 [TBL] [Abstract][Full Text] [Related]
11. A sensitive ligase-based ATP electrochemical assay using molecular beacon-like DNA. Wang Y; He X; Wang K; Ni X Biosens Bioelectron; 2010 May; 25(9):2101-6. PubMed ID: 20299199 [TBL] [Abstract][Full Text] [Related]
12. Y-type, C-rich DNA probe for electrochemical detection of silver ion and cysteine. Gong H; Li X Analyst; 2011 Jun; 136(11):2242-6. PubMed ID: 21512696 [TBL] [Abstract][Full Text] [Related]
13. High-sensitive electrochemical detection of point mutation based on polymerization-induced enzymatic amplification. Feng K; Zhao J; Wu ZS; Jiang J; Shen G; Yu R Biosens Bioelectron; 2011 Mar; 26(7):3187-91. PubMed ID: 21239161 [TBL] [Abstract][Full Text] [Related]
14. Polytyrosine as an electroactive label for signal amplification in electrochemical immunosensors. Gao Y; Cranston R Anal Chim Acta; 2010 Feb; 659(1-2):109-14. PubMed ID: 20103111 [TBL] [Abstract][Full Text] [Related]
15. A reusable DNA single-walled carbon-nanotube-based fluorescent sensor for highly sensitive and selective detection of Ag+ and cysteine in aqueous solutions. Zhao C; Qu K; Song Y; Xu C; Ren J; Qu X Chemistry; 2010 Jul; 16(27):8147-54. PubMed ID: 20512822 [TBL] [Abstract][Full Text] [Related]
16. Amplified and selective detection of Ag+ ions based on electrically contacted enzymes on duplex-like DNA scaffolds. Xu G; Wang G; Zhu Y; Chen L; He X; Wang L; Zhang X Biosens Bioelectron; 2014 Sep; 59():269-75. PubMed ID: 24732605 [TBL] [Abstract][Full Text] [Related]
17. DNA based gold nanoparticles colorimetric sensors for sensitive and selective detection of Ag(I) ions. Li B; Du Y; Dong S Anal Chim Acta; 2009 Jun; 644(1-2):78-82. PubMed ID: 19463566 [TBL] [Abstract][Full Text] [Related]
18. Detection of silver(I) ions based on the controlled self-assembly of a perylene fluorescence probe. Yang Y; Li W; Qi H; Zhang Q; Chen J; Wang Y; Wang B; Wang S; Yu C Anal Biochem; 2012 Nov; 430(1):48-52. PubMed ID: 22864232 [TBL] [Abstract][Full Text] [Related]
19. Electrochemical DNA biosensor based on chitosan/nano-V2O5/MWCNTs composite film modified carbon ionic liquid electrode and its application to the LAMP product of Yersinia enterocolitica gene sequence. Sun W; Qin P; Gao H; Li G; Jiao K Biosens Bioelectron; 2010 Feb; 25(6):1264-70. PubMed ID: 19926468 [TBL] [Abstract][Full Text] [Related]
20. Magnified fluorescence detection of silver(I) ion in aqueous solutions by using nano-graphite-DNA hybrid and DNase I. Wei Y; Li B; Wang X; Duan Y Biosens Bioelectron; 2014 Aug; 58():276-81. PubMed ID: 24657649 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]