BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

302 related articles for article (PubMed ID: 22613516)

  • 1. First report of a novel abluminal groove filled biodegradable polymer rapamycin-eluting stent in de novo coronary artery disease: results of the first in man FIREHAWK trial.
    Qian J; Xu B; Lansky AJ; Yang YJ; Qiao SB; Wu YJ; Chen J; Hu FH; Yang WX; Mintz GS; Leon MB; Gao RL
    Chin Med J (Engl); 2012 Mar; 125(6):970-6. PubMed ID: 22613516
    [TBL] [Abstract][Full Text] [Related]  

  • 2. First-in-human evaluation of a bioabsorbable polymer-coated sirolimus-eluting stent: imaging and clinical results of the DESSOLVE I Trial (DES with sirolimus and a bioabsorbable polymer for the treatment of patients with de novo lesion in the native coronary arteries).
    Ormiston J; Webster M; Stewart J; Vrolix M; Whitbourn R; Donohoe D; Knape C; Lansky A; Attizzani GF; Fitzgerald P; Kandzari DE; Wijns W
    JACC Cardiovasc Interv; 2013 Oct; 6(10):1026-34. PubMed ID: 24055443
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A prospective multicenter parallel-controlled trial of TIVOLI biodegradable-polymer-based sirolimus-eluting stent compared to ENDEAVOR zotarolimus-eluting stent for the treatment of coronary artery disease: 8-month angiographic and 2-year clinical follow-up results.
    Xu B; Dou KF; Han YL; Lü SZ; Yang YJ; Huo Y; Wang LF; Chen YD; Wang HC; Li WM; Chen JY; Wang L; Wang Y; Ge JB; Li W; Gao RL
    Chin Med J (Engl); 2011 Mar; 124(6):811-6. PubMed ID: 21518585
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A randomised comparison of a novel abluminal groove-filled biodegradable polymer sirolimus-eluting stent with a durable polymer everolimus-eluting stent: clinical and angiographic follow-up of the TARGET I trial.
    Gao RL; Xu B; Lansky AJ; Yang YJ; Ma CS; Han YL; Chen SL; Li H; Zhang RY; Fu GS; Yuan ZY; Jiang H; Huo Y; Li W; Zhang YJ; Leon MB;
    EuroIntervention; 2013 May; 9(1):75-83. PubMed ID: 23685298
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Long term safety and efficacy of a novel abluminal groove-filled biodegradable polymer sirolimus-eluting stent for the treatment of coronary de novo lesions].
    Li CJ; Xu B; Guan CD; Gao RL;
    Zhonghua Xin Xue Guan Bing Za Zhi; 2017 Nov; 45(11):940-947. PubMed ID: 29166720
    [No Abstract]   [Full Text] [Related]  

  • 6. Efficacy and safety of FIREHAWK® abluminal groove filled biodegradable polymer sirolimus-eluting stents for the treatment of long coronary lesions: nine-month angiographic and one-year clinical results from TARGET I trial long cohort.
    Xu B; Gao RL; Zhang RY; Wang HC; Li ZQ; Yang YJ; Ma CS; Han YL; Lansky AJ; Huo Y; Li W; Leon MB
    Chin Med J (Engl); 2013 Mar; 126(6):1026-32. PubMed ID: 23506573
    [TBL] [Abstract][Full Text] [Related]  

  • 7. First-in-man study evaluating the safety and efficacy of a second generation biodegradable polymer sirolimus-eluting stent in the treatment of patients with de novo coronary lesions: clinical, Angiographic, and OCT outcomes of CREDIT-1.
    Wang G; Sun Z; Jin Q; Xu K; Li Y; Wang X; Ma Y; Liu H; Zhao X; Wang B; Deng J; Guan S; Ge M; Wang X; Xu B; Han Y
    Catheter Cardiovasc Interv; 2015 Mar; 85 Suppl 1():744-51. PubMed ID: 25630447
    [TBL] [Abstract][Full Text] [Related]  

  • 8. First report of a novel polymer-free dual-drug eluting stent in de novo coronary artery disease: results of the first in human BICARE trial.
    Yu M; Xu B; Kandzari DE; Wu Y; Yan H; Chen J; Qian J; Qiao S; Yang Y; Gao RL
    Catheter Cardiovasc Interv; 2014 Feb; 83(3):405-11. PubMed ID: 23857821
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Preclinical and early clinical experience with a biodegradable polymer-based, rapamycin-eluting, Indian drug-eluting coronary stent: the BIO-RAPID study.
    Bhargava B; Karthikeyan G; Shankar PB; Seth S; Singh S; Pr U; Lal AV; Mohanty M
    Indian Heart J; 2008; 60(3):228-32. PubMed ID: 19240312
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A comparison of clinical and angiographic outcomes after Excel bioabsorbable polymer versus Firebird durable polymer rapamycin-eluting stent for the treatment of coronary artery disease in a "real world" setting: six-month follow-up results.
    Liu HB; Xu B; Qiao SB; Yang YJ; Ma WH; Qin XW; Yao M; Wu YJ; Yuan JQ; Chen J; You SJ; Dai J; Xia R; Li JJ; Chen JL; Gao RL
    Chin Med J (Engl); 2007 Apr; 120(7):574-7. PubMed ID: 17442205
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Primary endpoint results of the EVOLVE trial: a randomized evaluation of a novel bioabsorbable polymer-coated, everolimus-eluting coronary stent.
    Meredith IT; Verheye S; Dubois CL; Dens J; Fajadet J; Carrié D; Walsh S; Oldroyd KG; Varenne O; El-Jack S; Moreno R; Joshi AA; Allocco DJ; Dawkins KD
    J Am Coll Cardiol; 2012 Apr; 59(15):1362-70. PubMed ID: 22341736
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Safety and efficacy of a novel abluminal groove-filled biodegradable polymer sirolimus-eluting stent for the treatment of de novo coronary lesions: 12-month results from the TARGET II trial.
    Xu B; Zhao Y; Yang Y; Zhang R; Li H; Ma C; Chen S; Wang J; Huo Y; Leon MB; Gao R
    Chin Med J (Engl); 2014; 127(6):1027-32. PubMed ID: 24622429
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Safety and efficacy of a novel abluminal groove-filled biodegradable polymer sirolimus-eluting stent for the treatment of de novo coronary lesions: two-year results from a prospective patient-level pooled analysis of TARGET trials.
    Gao Z; Zhang R; Xu B; Yang Y; Ma C; Li H; Chen S; Han Y; Yuan Z; Lansky AJ; Guan C; Leon MB; Gao R;
    Catheter Cardiovasc Interv; 2015 Mar; 85 Suppl 1():734-43. PubMed ID: 25678281
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Novel completed biodegradable polymer sirolimus-eluting stent versus durable polymer sirolimus-eluting stent in de novo lesions: nine-month angiographic and three-year clinical outcomes of HOPE trial.
    Yuan F; Chen X; Song X; Wang D; Zhang Z; Li W; Li Z; Li H; Chen X; Huo Y; Wang L; Lu C; Lu Q; Xu B; Li W; Lyu S;
    Chin Med J (Engl); 2014; 127(14):2561-6. PubMed ID: 25043067
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Randomized comparison of everolimus-eluting and paclitaxel-eluting stents: two-year clinical follow-up from the Clinical Evaluation of the Xience V Everolimus Eluting Coronary Stent System in the Treatment of Patients with de novo Native Coronary Artery Lesions (SPIRIT) III trial.
    Stone GW; Midei M; Newman W; Sanz M; Hermiller JB; Williams J; Farhat N; Caputo R; Xenopoulos N; Applegate R; Gordon P; White RM; Sudhir K; Cutlip DE; Petersen JL;
    Circulation; 2009 Feb; 119(5):680-6. PubMed ID: 19171853
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Feasibility of a novel abluminal groove-filled biodegradable polymer sirolimus-eluting stent in patients with complex anatomical and clinical scenarios.
    Zhang YJ; Wu W; Pan DR; Xu B; Kan J; Chen YX; Pang S; You W; Zhang JJ; Ye F; Chen SL
    Minerva Cardioangiol; 2015 Feb; 63(1):1-9. PubMed ID: 25670056
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Sirolimus-eluting cobalt-chromium stents: two-year clinical results from first-in-man study on the Firebird 2 stent.
    Xu B; Zhang Q; Yang YJ; Qiao SB; Zhang RY; Zhang JS; Hu J; Qin XW; Hong T; Li JP; Chen JL; Huo Y; Gao RL; Shen WF
    Chin Med J (Engl); 2008 Mar; 121(6):492-7. PubMed ID: 18364131
    [TBL] [Abstract][Full Text] [Related]  

  • 18. MAHOROBA, first-in-man study: 6-month results of a biodegradable polymer sustained release tacrolimus-eluting stent in de novo coronary stenoses.
    Onuma Y; Serruys P; den Heijer P; Joesoef KS; Duckers H; Regar E; Kukreja N; Tanimoto S; Garcia-Garcia HM; van Beusekom H; van der Giessen W; Nishide T
    Eur Heart J; 2009 Jun; 30(12):1477-85. PubMed ID: 19406868
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Safety and efficacy of a novel abluminal groove-filled biodegradable polymer sirolimus-eluting stent for the treatment of de novo coronary lesions: 5-year results of the TARGET Ⅱ trial].
    Xu LJ; Gao Z; Song Y; Wang HH; Xu JJ; Gao LJ; Zhang Y; Song L; Zhao XY; Chen J; Yuan JQ; Qiao SB; Yang YJ; Xu B; Gao RL;
    Zhonghua Xin Xue Guan Bing Za Zhi; 2018 Jul; 46(7):523-528. PubMed ID: 30032542
    [No Abstract]   [Full Text] [Related]  

  • 20. A polymer-free dual drug-eluting stent in patients with coronary artery disease: a randomized trial vs. polymer-based drug-eluting stents.
    Byrne RA; Mehilli J; Iijima R; Schulz S; Pache J; Seyfarth M; Schömig A; Kastrati A
    Eur Heart J; 2009 Apr; 30(8):923-31. PubMed ID: 19240066
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.